EX4200 CHECKLIST

**************************
- UNPACK THE BOX
- ASSIGN CHASSIS S/N WITH FPC OR MEMBER ID ON FRONT VIEW EX BOX
- MOUNTING TO RACK THE CHASSIS
- BOOTING MASTER & BACKUP LINE CARD
- ARRANGE VCP CABLE ON BACKWARD CHASSIS
- CONSOLE TO 0NE CHASSIS
- VERIFY JUNOS INSTALLED
- VERIFY CHASSIS S/N BY CLI
- VERIFY HARDWARE STATUS
- CONFIGURE VIRTUAL CHASSIS MEMBER BASE ON TOPOLOGY
- VERIFY VIRTUAL CHASSIS STATUS

- CONFIGURE LINK AGGREATION (LAG)


- SOFTWARE AVAILABILITY
- CONFIGURE SYSLOG & LOGGING SYSTEM
- CONFIGURE REDUNDANCY ROUTING ENGINE & GRECEFUL RESTART
- CONFIGURE NON-STOP ROUTING
- CONFIGURE RE-HARDENING
- CONFIGURE OTOMATION COMMIT SYNCRONIZE
- CONFIGURE FOR SUPPORT NON-STOP SOFTWARE UPGRADE
- CONFIFURE SYSTEM ARCHIVING

lab@s1> show virtual-chassis member-config


lab@s1> show virtual-chassis status
lab@s1> show virtual-chassis protocol database
lab@s1> show virtual-chassis protocol interface
lab@s1> show virtual-chassis protocol route
Local-repair
lab@s1# set system virtual-chassis fast-failover xe enable
lab@s1# set system virtual-chassis fast-failover ge enable

You might also like