PARAMETROS ELECTRICOS CABLES CAI-S

CONDUCTOR DE FASE
DENOMINACION CABLE

RESISTENCIA

REACTANCIA

OHMICA

INDUCTIVA

Rcc 20C

XL (60 Hz)

CONDUCTOR ADICIONAL (ALUMBRADO)

CAPACIDAD
CORRIENTE

FACTOR

RESISTENCIA

RESISTENCIA

CAPACIDAD
CORRIENTE

CAIDA

OHMICA

INDUCTIVA

TENSION

Rcc 20C

XL (60 Hz)

FACTOR
CAIDA
TENSION

Ohm/Km

Ohm/Km

V/A*KM

Ohm/Km

Ohm/Km

V/A*KM

CAI-S 2 x 6 mm

3,077

0,1202

59

6,42

CAI-S 3 x 10 mm

1,826

0,1246

82

3,36

CAI-S 3 x 10 + 1 x 6 mm

1,826

0,1246

82

3,36

3,077

0,1202

59

6,42

CAI-S 3 x 16 + 1 x 10 mm

1,152

0,1177

109

2,16

1,826

0,1121

82

3,86

CAI-S 3 x 25 + 1 x 10 mm

0,727

0,1163

147

1,41

1,826

0,1121

82

3,86

CAI-S 3 x 35 + 1 x 16 mm

0,524

0,1147

183

1,05

1,152

0,106

109

2,48

CAI-S 3 x 10 + 2 x 6 mm

1,826

0,1246

82

3,36

3,077

0,1202

59

6,42

CAI-S 3 x 16 +2 x 10 mm

1,152

0,1177

109

2,16

1,826

0,1121

82

3,86

CAI-S 3 x 25 + 2 x 10 mm

0,727

0,1163

147

1,41

1,826

0,1121

82

3,86

CAI-S 3 x 35 + 2 x 16 mm

0,524

0,1147

183

1,05

1,152

0,106

109

2,48

PARAMETROS MECANICOS CABLES CAI-S


DIAMETROS AISLADOS
DENOMINACION CABLE

CONDUCTOR
FASE

CONDUCTOR
ADICIONAL

PORTANTE
DIAMETRO
NOMINAL
(Desnudo)

CABLE TOTAL

CARGA
ROTURA

DIAMETRO
APROX.

PESO

mm

mm

mm

Kg

mm

Kg/Km

CAI-S 2 x 6 mm

5,5

3,18

830

11,4

205

CAI-S 3 x 10 mm

6,4

3,18

830

14,6

400

CAI-S 3 x 10 + 1 x 6 mm

6,4

5,5

3,18

830

16,2

470

CAI-S 3 x 16 + 1 x 10 mm

7,4

6,4

3,18

830

18,8

691

CAI-S 3 x 25 + 1 x 10 mm

9,1

6,4

4,76

1809

21,6

1049

CAI-S 3 x 35 + 1 x 16 mm

10,6

7,4

4,76

1809

25,2

1417

CAI-S 3 x 10 + 2 x 6 mm

6,4

5,5

3,18

830

17,6

544

CAI-S 3 x 16 + 2 x 10 mm

7,4

6,4

3,18

830

20,5

804

CAI-S 3 x 25 + 2 x 10 mm

9,1

6,4

4,76

1809

22,7

1162

CAI-S 3 x 35 + 2 x 16 mm

10,6

7,4

4,76

1809

26,5

1589

PARAMETROS Y FACTORES DE CAIDA DE TENSION DE LOS CABLES AUTOPOR


CONDUCTOR DE FASE
TIPO DE CONDUCTOR

RESISTENCIA
OHMICA (ohms/Km)
A 20 C

REACTANCIA
INDUCTIVA
(ohms/Km)

FACTOR DE CAIDA DE
TENSION (ohms/Km)

A 40 C

CONDUCTO
CAPACIDAD
DE
CORRIENTE
(A)

RESISTENCIA OHMICA Rcc


20 C (ohms/Km)
A 20 C

PARAMETROS ELECTRICOS CABLES CAAI-S


a

7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

2x16 mm2

0.000

0.000

0.000

0.000

85

1.870

2x25 mm2

1.180

1.265

0.099

2.363

114

2x35 mm2

0.851

0.912

0.096

1.725

141

3x16 mm2

1.870

2.005

0.115

3.212

85

3x25 mm2

1.180

1.265

0.111

2.056

114

3x35 mm2

0.851

0.912

0.107

1.503

141

2x16 + 1x16 mm2

1.870

2.005

0.103

3.699

85

2x25 + 1x16 mm2

1.180

1.265

0.099

2.046

114

2x35 + 1x16 mm2

0.851

0.912

0.096

1.494

141

3x16 + 1x16 mm2

1.870

2.005

0.103

3.204

85

3x25 + 1x16 mm2

1.180

1.265

0.099

2.046

114

3x35 + 1x16 mm2

0.851

0.912

0.096

1.494

141

3x16 + 2x16 mm2

1.870

2.005

0.103

3.204

85

1.87

3x25 + 2x16 mm2

1.180

1.265

0.111

2.056

114

1.87

3x35 + 2x16 mm2

0.851

0.912

0.107

1.503

141

1.87

1
Calificacion
Pot. Lampara

700 W/Lote
0.080 kW/Lamp
0.170 kW/Lamp

Factor Simultaneidad
COS =
Sistema

0.50

0.90
380

220

POT (KVA)
75
50
37.5

MAX. DEM. (KW)


80%
100%
47.51
59.39
31.67
39.59
23.76
29.70

r40 C= r20 C [ 1 + (t2 - 20)]


Donde :
r 40 C = resistencia elctrica del conductor a 40 C
r 20 C = resistencia elctrica del conductor a 20C
= Coeficiente de correccin de temperatura 1/C : 0,0036

t2
= 40 C
Para circuitos trifsicos K= 3 (r1cos +X1 Sen )
Para circuitos monofsicos K= 2 (r2 cos +X2 Sen )

DE CAIDA DE TENSION DE LOS CABLES AUTOPORTANTES


CONDUCTOR ADICIONAL (ALUMBRADO)
REACTANCIA
INDUCTIVA
(ohms/Km)

FACTOR DE
CAIDA DE
TENSION
(ohms/Km)

CAPACIDAD
DE
CORRIENTE
(A)

2.005

0.103

3.699

0.000

0.000

0.000

0.000

0.000

0.000

85

0.000

85

0.000

85

0.000

85

0.000

85

0.000

85

2.01

0.1

3.699

85

2.01

0.1

3.699

85

2.01

0.1

3.699

85

RESISTENCIA OHMICA Rcc


20 C (ohms/Km)
A 40 C

ROS ELECTRICOS CABLES CAAI-S

CANT. LOTES
80%
100%
136
170
90
113
68
85

10

11

CALCULOS ELECTRICOS EN REDES DE BAJA TENSION


: SISTEMA DE DISTRIBUCION EN B.T. PARA H.U.P. "LOS DELFINES"

PROYECTO
DISTRITO
PROVINCIA
DEPARTAMENTO

: NUEVO CHIMBOTE
: SANTA
: ANCASH

SERVICIO
P
U
N
T
O

FORMACION
CONDUCTOR
(mm)

1
2
3

2x25 mm2
2x25 mm2
2x25 mm2

S.A.M. N
CIRCUITO
SISTEMA
Calificacion
Pot. Lampara

N
Lotes

Suma
Lotes

C.E.

(kW)
0
4
4

8
8
4

PARTICULAR

ALUMBRADO

Suma
C.E

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

(kW)

(kW)

(A)

(m)

(/Km.)

(V)

(V)

0
0
0

1.60
1.60
0.80

8.08
8.08
4.04

5.00
500.00
1000.00

2.363
2.363
2.363

0.10
9.55
9.55

0.10
9.64
19.19

Suma
Caida de
Tension
(%)

P
U
N
T
O

0.04
4.38
8.72

1
2
3

:
:
:
:
:

1
A
220
/ 220 V
400 W/Lote

PERDIDA
POTENCIA
#VALUE!

0.080 kW/Lamp

PUBLICO

N
Lamp.

Suma
Lamp.

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

PERDIDA
POTENCIA

70 W

70 W

(Kw)

(A)

(m)

(/Km.)

(V)

(V)

(kW)

0.00
0.00
0.00

#VALUE!
#VALUE!
#VALUE!

0
1
1

2
2
1

0.16
0.16
0.08

0.81
5.00
0.81 500.00
0.40 1000.00

0.000
0.000
0.000

0.00
0.00
0.00

CALCULOS ELECTRICOS EN REDES DE BAJA TENSION


: SISTEMA DE DISTRIBUCION EN B.T. PARA H.U.P. "LOS DELFINES"

PROYECTO
DISTRITO
PROVINCIA
DEPARTAMENTO

S.A.M. N
CIRCUITO
SISTEMA
Calificacion
Pot. Lampara

: NUEVO CHIMBOTE
: SANTA
: ANCASH

SERVICIO

PARTICULAR

ALUMBRADO

P
U
N
T
O

FORMACION
CONDUCTOR
(mm)

1
2
3
4
5
6
7
8

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2

5
3
4
2
0
4
5
3

38
33
30
14
12
12
8
3

0
0
0
0
0
0
0
0

7.60
6.60
6.00
2.80
2.40
2.40
1.60
0.60

38.38
33.33
30.30
14.14
12.12
12.12
8.08
3.03

5.00
30.00
30.00
30.00
15.00
35.00
35.00
35.00

3.204
3.204
3.204
3.204
3.204
3.204
3.204
3.204

0.61
3.20
2.91
1.36
0.58
1.36
0.91
0.34

3.1
3.2
3.3

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2

3
4
5

12
9
5

0
0
0

2.40
1.80
1.00

12.12
9.09
5.05

15.00
35.00
35.00

3.204
3.204
3.204

3.2.1
3.2.2

2x16 mm2
2x16 mm2

0
0

0
0

0
0

0.00
0.00

0.00
0.00

14.00
30.00

3.2.1.1

2x16 mm2

0.00

0.00

5.1

3x16 + 2x16 mm2

0.00

0.00

N
Lotes

Suma
Lotes

C.E.

(kW)

Suma
C.E

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

(kW)

(kW)

(A)

(m)

(/Km.)

(V)

(V)

:
:
:
:
:

1
B
380
/ 220 V
700 W/Lote

PERDIDA
POTENCIA
#VALUE!

0.080 kW/Lamp

PUBLICO

Suma
Caida de
Tension
(%)

P
U
N
T
O

N
Lamp.

Suma
Lamp.

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

PERDIDA
POTENCIA

70 W

70 W

(Kw)

(A)

(m)

(/Km.)

(V)

(V)

(kW)

0.61
3.82
6.73
8.09
8.67
10.03
10.94
11.28

0.28
1.74
3.06
3.68
3.94
4.56
4.97
5.13

1
2
3
4
5
6
7
8

1
1
1
1
1
1
1
1

15
14
13
6
5
3
2
1

1.20
1.12
1.04
0.48
0.40
0.24
0.16
0.08

6.06
5.66
5.25
2.42
2.02
1.21
0.81
0.40

5.00
30.00
30.00
30.00
15.00
35.00
35.00
35.00

3.699
3.699
3.699
3.699
3.699
3.699
3.699
3.699

0.11
0.63
0.58
0.27
0.11
0.16
0.10
0.05

0.11
0.74
1.32
1.59
1.70
1.86
1.97
2.02

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0.58
1.02
0.57

7.31
8.33
8.90

3.32
3.79
4.05

3.1
3.2
3.3

1
1
1

6
5
1

0.48
0.40
0.08

2.42
2.02
0.40

15.00
35.00
35.00

3.699
3.699
3.699

0.13
0.26
0.05

1.46
1.72
1.77

#VALUE!
#VALUE!
#VALUE!

0.000
0.000

0.00
0.00

8.33
8.33

3.79
3.79

3.2.1
3.2.2

1
1

3
1

0.24
0.08

1.21
0.40

14.00
30.00

3.699
3.699

0.06
0.04

1.78
1.83

#VALUE!
#VALUE!

30.00

0.000

0.00

8.33

3.79

3.2.1.1

0.08

27.00

3.204

0.00

8.67

3.94

5.1

0.08

0.40

30.00

3.699

0.04

1.83

#VALUE!

0.40

27.00

3.699

0.04

1.74

#VALUE!

CALCULOS ELECTRICOS EN REDES DE BAJA TENSION


PROYECTO
DISTRITO
PROVINCIA
DEPARTAMENTO

: SISTEMA DE DISTRIBUCION EN B.T. PARA U.P. "LOS DELFINES"

S.A.M. N
CIRCUITO
SISTEMA
Calificacion
Pot. Lampara

: NUEVO CHIMBOTE
: SANTA
: ANCASH

SERVICIO
P
U
N
T
O

FORMACION
CONDUCTOR
(mm)

1
2
3
4
5
6
7
8

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2

0
2
0
0
2
2
4
2

36
21
19
10
10
8
6
2

1.1
1.2
1.3

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2

5
7
3

15
10
3

3.1
3.2
3.3

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2

2
4
3

9
7
3

N
Lotes

Suma
Lotes

C.E.

(kW)

2.00

2.00

PARTICULAR

ALUMBRADO

Suma
C.E

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

(kW)

(kW)

(A)

(m)

(/Km.)

(V)

(V)

Suma
Caida de
Tension
(%)

P
U
N
T
O

:
:
:
:
:

2
A
380
/ 220 V
700 W/Lote

PERDIDA
POTENCIA
#VALUE!

0.080 kW/Lamp

PUBLICO

N
Lamp.

Suma
Lamp.

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

PERDIDA
POTENCIA

70 W

70 W

(Kw)

(A)

(m)

(/Km.)

(V)

(V)

(kW)

4
2
2
2
2
2
0
0

11.20
6.20
5.80
4.00
4.00
3.60
1.20
0.40

56.57
31.31
29.29
20.20
20.20
18.18
6.06
2.02

5.00
28.00
12.00
28.00
15.00
35.00
35.00
35.00

3.204
3.204
3.204
3.204
3.204
3.204
3.204
3.204

0.91
2.81
1.13
1.81
0.97
2.04
0.68
0.23

0.91
3.72
4.84
6.65
7.62
9.66
10.34
10.57

0.41
1.69
2.20
3.02
3.47
4.39
4.70
4.80

1
2
3
4
5
6
7
8

0
1
1
1
1
1
1
1

13
10
9
5
4
3
2
1

1.04
0.80
0.72
0.40
0.32
0.24
0.16
0.08

5.25
4.04
3.64
2.02
1.62
1.21
0.81
0.40

5.00
28.00
12.00
28.00
15.00
35.00
35.00
35.00

3.699
3.699
3.699
3.699
3.699
3.699
3.699
3.699

0.10
0.42
0.16
0.21
0.09
0.16
0.10
0.05

0.10
0.52
0.68
0.89
0.98
1.13
1.24
1.29

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

2
2
2

5.00
4.00
2.60

25.25
20.20
13.13

18.00
30.00
30.00

3.204
3.204
3.204

1.46
1.94
1.26

2.36
4.30
5.57

1.07
1.96
2.53

1.1
1.2
1.3

1
1
1

3
2
1

0.24
0.16
0.08

1.21
0.81
0.40

18.00
30.00
30.00

3.699
3.699
3.699

0.08
0.09
0.04

0.18
0.27
0.31

#VALUE!
#VALUE!
#VALUE!

0
0
0

1.80
1.40
0.60

9.09
7.07
3.03

20.00
30.00
30.00

3.204
3.204
3.204

0.58
0.68
0.29

5.42
6.10
6.40

2.47
2.77
2.91

3.1
3.2
3.3

1
1
1

3
2
1

0.24
0.16
0.08

1.21
0.81
0.40

20.00
30.00
30.00

3.699
3.699
3.699

0.09
0.09
0.04

0.77
0.86
0.90

#VALUE!
#VALUE!
#VALUE!

CALCULOS ELECTRICOS EN REDES DE BAJA TENSION


: SISTEMA DE DISTRIBUCION EN B.T. PARA U.P. "LOS DELFINES"

PROYECTO
DISTRITO
PROVINCIA
DEPARTAMENTO

S.A.M. N
CIRCUITO
SISTEMA
Calificacion
Pot. Lampara

: NUEVO CHIMBOTE
: SANTA
: ANCASH

SERVICIO

PARTICULAR

ALUMBRADO

P
U
N
T
O

FORMACION
CONDUCTOR
(mm)

1
2
3
4
5
6
7

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2
3x16 + 2x16 mm2

2
2
4
0
2
4
5

37
35
33
14
14
9
5

0
0
0
0
0
0
0

7.40
7.00
6.60
2.80
2.80
1.80
1.00

37.37
35.35
33.33
14.14
14.14
9.09
5.05

5.00
30.00
30.00
30.00
13.00
35.00
35.00

3.204
3.204
3.204
3.204
3.204
3.204
3.204

0.60
3.40
3.20
1.36
0.59
1.02
0.57

3.1
3.2
3.3
3.4
3.5

3x16 + 2x16 mm2


3x16 + 2x16 mm2
3x16 + 2x16 mm2
2x16 mm2
2x16 mm2

6
6
3
0
0

15
9
3
0
0

0
0
0
0
0

3.00
1.80
0.60
0.00
0.00

15.15
9.09
3.03
0.00
0.00

15.00
30.00
30.00
13.00
28.00

3.204
3.204
3.204
0.000
0.000

3.4.1
3.4.2
3.4.3

2x16 mm2
2x16 mm2
2x16 mm2

0
0
0

0
0
0

0
0
0

0.00
0.00
0.00

0.00
0.00
0.00

35.00
35.00
30.00

5.1

3x16 + 2x16 mm2

0.60

3.03

30.00

N
Lotes

Suma
Lotes

C.E.

(kW)

Suma
C.E

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

(kW)

(kW)

(A)

(m)

(/Km.)

(V)

(V)

:
:
:
:
:

2
B
380
/ 220 V
700 W/Lote

PERDIDA
POTENCIA
#VALUE!

0.080 kW/Lamp

PUBLICO

Suma
Caida de
Tension
(%)

P
U
N
T
O

N
Lamp.

Suma
Lamp.

Pot.
Total

Caida de
Tension

Suma
Caida de
Tension

PERDIDA
POTENCIA

70 W

70 W

(Kw)

(A)

(m)

(/Km.)

(V)

(V)

(kW)

0.60
4.00
7.20
8.56
9.15
10.17
10.74

0.27
1.82
3.27
3.89
4.16
4.62
4.88

1
2
3
4
5
6
7

1
1
1
1
1
1
1

16
15
14
5
4
2
1

1.28
1.20
1.12
0.40
0.32
0.16
0.08

6.46
6.06
5.66
2.02
1.62
0.81
0.40

5.00
30.00
30.00
30.00
13.00
35.00
35.00

3.699
3.699
3.699
3.699
3.699
3.699
3.699

0.12
0.67
0.63
0.22
0.08
0.10
0.05

0.12
0.79
1.42
1.64
1.72
1.83
1.88

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0.73
0.87
0.29
0.00
0.00

7.93
8.80
9.09
9.09
9.09

3.60
4.00
4.13
4.13
4.13

3.1
3.2
3.3
3.4
3.5

1
1
1
1
1

8
7
6
5
1

0.64
0.56
0.48
0.40
0.08

3.23
2.83
2.42
2.02
0.40

15.00
30.00
30.00
13.00
28.00

3.699
3.699
3.699
3.699
3.699

0.18
0.31
0.27
0.10
0.04

1.60
1.91
2.18
2.28
2.32

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0.000
0.000
0.000

0.00
0.00
0.00

9.09
9.09
9.09

4.13
4.13
4.13

3.4.1
3.4.2
3.4.3

1
1
1

3
2
1

0.24
0.16
0.08

1.21
0.81
0.40

35.00
35.00
30.00

3.699
3.699
3.699

0.16
0.10
0.04

2.44
2.54
2.59

#VALUE!
#VALUE!
#VALUE!

3.204

0.29

9.44

4.29

5.1

0.08

0.40

30.00

3.699

0.04

1.77

#VALUE!

CUADRO

DE

SERVICIO PARTICULAR

S.A.M.

N 01

Proyec =

CIRCUITO

N LOTES

C.E.

ALUMBRADO PUBLICO

P.

P. TOTAL

(KW)

(KW)

(A)

LAMPARAS

(KW)

(A)

(KW)

0.00

1.60

8.08

0.16

0.81

1.76

38

0.00

7.60

38.38

15

1.20

6.06

8.80

TOTAL

46

0.00

9.20

46.46

17

1.36

6.87

10.56

4 aos

CIRCUITO

DE

37.5

N LOTES

C.E.

P.

CARGAS
ALUMBRADO PUBLICO

P.

SUB-TOTAL
I

P. TOTAL

TOTAL

(KW)

(KW)

(A)

LAMPARAS

(KW)

(A)

(KW)

36

4.00

11.20

56.57

13

1.04

5.25

12.24

37

0.00

7.40

37.37

16

1.28

6.46

8.68

TOTAL

73

4.00

18.60

93.94

29

2.32

11.72

20.92

25 KVA

KVA

46

4 aos

POT. TRANSF.

0
34% Tiene Reserva

SERVICIO PARTICULAR

Proyec =

SUB-TOTAL
I

TOTAL

CUADRO

N 02

P.

13 KVA

S.A.M.

CARGAS

0
67% Tiene Reserva

POT. TRANSF.
KVA

37.5

73

MAXIMA DEMANDA
A=
B=
C=

0.600
0.500
0.400

101 - mas Habitantes


61 - 100 Habitantes
0 - 60 Habitantes

0.600
0.058

156

CARGAS A ALIMENTAR S.A.M. N01


SECTORES

M.D. (Kw)

Cantidad

F.S

kW

Domestico

0.600

#REF!

0.50

#REF!

Alumbrado Publico

0.058

#REF!

1.00

#REF!

0.60
0.50
0.80
0.80
0.50

1
1
1
1
1

1.0
1.0
1.0
1.0
1.0

0.60
0.50
0.80
0.80
0.50

Cargas especiales
* Local Municipal
* Iglesia
* Centro Educativo
* C.E. Primario
* Tienda
SubTotal

#REF!

Perdidas en Distribucion (5%)

#REF!

Potencia Total (cos =0,90)

#REF!

POTENCIA DEL TRANSFOMADOR

#REF!

3.20

#REF!
#REF!

#REF!