Quick Disconnect Coupling, Model : QDC

Ref. No : H03297, Release Jan 2006 (Dimensions in mm)

the right connection

Description Quick disconnect couplings are designed for applications where fast connection and disconnection of hydraulic lines is a need of the system. These coupling when connected offer unrestricted flow passage. They are designed for reliable and safe operations by avoiding premature flow before the coupling is fully closed.

Section (Self sealing Coupling, Self sealing Adaptor, Illustrated) Hydraulic Symbol Coupling Type Through type Adaptor Through type Coupling Self sealing Adaptor Through type Coupling Through type Adaptor Self sealing Coupling Self sealing Adaptor Self sealing Coupling Adaptor Coupling AT CT AS CT AT CS AS CS

Unit Dimensions End connections (Female) BSP Metric - G -M S1 A/F S2 A/F

G/M

G/M

Table 1
Pressure (bar) 800 800 600 500 400 G G 1/4 G 3/8 G 1/2 G 3/4 G1 M M14x1.5 M18x1.5 M22x1.5 M26x1.5 M33x2.0 S1 27 32 41 50 55 S2 19 22 30 36 41 D 35 37 46 56 62 L 86 88 116 130 150

Copyrights 2006

hyloc hydrotechnic pvt. ltd.

All rights reserved

Engineering Datasheet, Page 1/2

Quick Disconnect Coupling, Model : QDC


Ref. No : H03297, Release Jan 2006 (Dimensions in mm)

the right connection

Technical Specifications

Construction Operating pressure Hydraulic medium Viscosity range Fluid temperature range Fluid cleanliness Maximum flow handling capacity

Poppet type. Refer table no.1 Mineral oil. 10 cSt to 380 cSt. -20 oC to +80 oC. As per ISO code 19/16 or better M14 x 1.5 G 1/4 M18 x 1.5 G 3/8 - 30 lpm M22 x 1.5 G 1/2 M26 x 1.5 G 3/4 M33 x 2.0 G 1

Caution : Pressure on the hydraulic lines must be relieved before they are connected/disconnected.

Ordering Code

QDC 800 G02 AS

CS

304 P

2.0
Design Series Subject to revision Surface treatment Omit Zinc plated and Yellow chromated P Phosphating Body Material Omit Steel 304 SS 304 316 SS 316 Seal material Omit Nitrile V FKM X Without O-Ring Coupling Type Omit For Adaptor Only CS CT Self sealing Through type

Quick Disconnect Coupling

Pressure Range G 1/4 G 3/8 G 1/2 G 3/4 G1 M14x1.5 M18x1.5 M22x1.5 M26x1.5 M33x2.0 800 800 600 500 400

End Connections G 1/4 G 3/8 G 1/2 G 3/4 G1 M14x1.5 M18x1.5 M22x1.5 M26x1.5 M33x2.0 G02 G03 G04 G06 G08 M14 M18 M22 M26 M33

Adaptor Type Omit For Coupling Only AS Self sealing AT Through type