Type of Primary Scrubber inclined TM14-AA-01, 5C,6A Boiler Width m 5.62 Maximum Evaporation Ws kg/s 19.

44 Circulation Ratio C 40 Steam Cyclone Capacity Drum Design Pressure kg/cm2(g) 24 PSIG 341.36 "Cyclone Standard Steam capacity" ws kg/s 1.35 "Upgrated cyclone steam capacity" ws' kg/s 1.73 Cyclone water capacity ww kg/s 40.95 Number of cyclone required Number of cyclone( As per Steam) N nos 14 Number of cyclone(As per Water) N nos 19 19 Feed system ( TM 14-AC 2) Water flow W kg/s 19.44 Diameter of Hole on Sparge pipe D mm 12 Working pressure of drum P kg/cm2(a) 24 Saturation Temperature T Deg C 220.8 Specific Volume water at Working Pressure v m3/kg 0.0012 Densiity of water kg/m3 839 Min No of holes on Sparge pipe N nos 56 Area A m2 0.006 Velocity (Max 3.7 m/s @ MCR) V m/s 3.684 Feed Pipe Velocity V m/s 2.76 Number of feed Points into drum nos 2 Min Feed pipe Inlet area a m2 0.0041926 Min Feed pipe Inlet Diameter d mm 73 [5:06:49 PM] kamesh: now you chec your calculation [5:06:55 PM] kamesh: if you have any dout tell me [5:07:00 PM] ABDUL BASIT: ok [5:07:40 PM] kamesh: for drum internal you read the TM 14 chapter from first pag e to last [5:08:03 PM] kamesh: calculation part is only the portion what we have done till now [5:08:20 PM] kamesh: you list out the component of drum internal and mail me [5:08:34 PM] kamesh: i will tell you weather it is correct or wrong [5:08:46 PM] ABDUL BASIT: ok sir [5:09:19 PM] kamesh: abdul , let work with some time frame . when you will get b ack to me after completeling all this as a repot format