ETABSi
ACI 318-05/IBC 2003 BEAM SECTION DESIGN Level Element Section ID Combo ID Station Loc : : : : : STORY1 B8 V25X70 CORTE8 470.000 0.900 0.750 0.600 0.750 L=500.000 D=70.000 ds=0.000 E=253.105 fy=4.218
Units: Ton-cm
(Shear Details)
SHEAR/TORSION DESIGN FOR V2 and T Rebar Rebar Av/s At/s O/S #45 0.047 Design Forces Factored Vu 9.045 Factored Mu -1481.739
Rebar Al 7.259
Design Tu 248.866
Design Mu 1385.199
Design Pu 0.000
Capacity Vp 13.511
Capacity Moment (Left) Long.Rebar Long.Rebar Cap.Moment Cap.Moment As(Bot) As(Top) Mpos Mneg 7.977 9.692 2692.093 3205.562 Capacity Moment (Right) Long.Rebar Long.Rebar Cap.Moment Cap.Moment As(Bot) As(Top) Mpos Mneg 7.653 9.845 2582.682 3252.819 Design Basis Design Vu 16.520 Conc.Area Ac 1675.000 Area Tensn.Rein Ag Ast 1750.000 7.653 RebarArea Av 0.078 Conc.Area Aoh 984.482 Strength Fys 4.218 Shear Phi*Vc 0.000 Conc.Area Ao 836.810 Strength LtWt.Reduc Fcs Factor 0.281 1.000 Shear Phi*Vs 16.520 Perimeter Pcp 190.000 Shear Phi*Vn 16.520 Perimeter Ph 154.440
Shear Rebar Design Stress Conc.Cpcty Uppr.Limit v vc vmax 0.010 0.007 0.036 Torsion Capacity Torsion Tu 248.866 O/S #45 Critical Phi*Tcr 53.754 Conc.Area Acp 1750.000
Shear stress due to shear force and torsion together exceeds maximum allowed