MGP-F35W/S
MGP-F60W/S
MGP-F80W/S
MGP-F100W/S
MGP-F120W/S
MGP-F135W/S
Cooling capacity
kW
35
60
80
100
120
135
145
Rated power
kW
8.75
15.2
19
23.8
29.5
34.1
37.2
W/W
3.95
3.95
4.07
3.97
3.9
3.9
17.8
30.9
37.2
45
58.5
62.5
68.2
SM148T4V
(DANFOSS)
SM161-4VAM
(DANFOSS)
SM161-4VAM
(DANFOSS)
8.03
9.53
10.53
3.03
3.33
3.33
9.53
Model
EER
Rated current
Power supply
380V3N 50Hz
Type
Model & Brand
503dh-83C2Y
(HITACHI)
503dh-83C2Y
(HITACHI)
603dh-90C2Y
(HITACHI)
3.62
3.054
4.04
1.82
1.84
1.84
Start-up mode
Compressor
Output power
kg
R22
82
92
83
9.03
9.53
kW
1.5
2.8
5.3
5.5
5.5
5.7
m3/h
6500
11000
14000
18200
20600
20600
22000
Pa
147
147
147
147
147
230
250
m3/h
7.5
12.9
16.5
22.1
26.7
28.8
30.9
Driving mode
Air volume
Static pressure
Water Volume
Cooling water Water resistance
side
Diameter of inlet water pipe
Diameter of outlet water pipe
1.86
81
Wind-wheel
Motor
3.056
Mineral oil
Type
Refrigeration
Scroll
503dh-83C2Y
(HITACHI)
Direct start-up
kW
Standard
Lubricating oil
Fan motor
MGP-F145W/S
Strap
Pa
9806
9806
9806
9806
9806
9806
9806
mm/inch
40(1-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
mm/inch
40(1-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
65(2-1/2")
Outlet of evaporator
mm/inch
25(1")
25(1")
25(1")
25(1")
25(1")
25(1")
25(1")
Outlet of plate
mm/inch
25(1")
25(1")
25(1")
25(1")
25(1")
25(1")
25(1")
Height (before/after)
mm
1839/2047
1839/2047
1839/2047
1839/2047
1839/2047
1839/2047
1839/2047
Length (before/after)
mm
1090/1250
1420/1604
1420/1604
1912/2152
1912/2152
1912/2152
1912/2150
Width (before/after)
mm
1055/1230
1055/1230
1055/1230
1055/1230
1055/1230
1055/1230
1055/1230
kg
430/470
690/723
700/733
820/870
830/880
840/890
850/900
Net/Cross weight
Protection device
Over-load protection, high/low pressure protection, anti-frost protection, and inner temp. Protection of compressor, phase- sequence
High pressure protection
kgf/cm2
24
24
24
24
24
24
24
Low pressure protection
kgf/cm2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
dB(A)
60
66
66
74
74
75
72
Noise level
Remark:1.Cooling test condition:indoor dry bull 27/19, condenser inlet/outlet water temp. 30/35;
2.The parameter do not including the power input of cooling tower fan motor and water pump.
10345.6 13314.79