Professional Documents
Culture Documents
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
INDICE
1 2 3 4 INTRODUCERE...........................................................................................................................................0 NOIUNI DE TEORIE: LUMINA SOLAR I ENERGIA ............................................................................0 ABSORBIA (CAPTAREA) LUMINII SOLARE DE CTRE SUPRAFEE ................................................0 COLECTOR SOLAR ...................................................................................................................................0
4.1 NCLINAIA COLECTOARELOR.....................................................................................................................................................0 ANUAL..............................................................................................................................................................................................0 4.2 VALORI ALE ENERGIEI SOLARE INCIDENTE ..................................................................................................................................0
5 6
8 9 10
PUNEREA INSTALAIEI N FUNCIUNE ..................................................................................................0 NTREINEREA (REVIZIA) I IDENTIFICAREA DEFECIUNILOR ..........................................................0 APENDICE TEORETIC: CALCULUL EFICIENEI UNUI PANOU SOLAR ............................................0
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
1 Introducere
Panourile solare sunt echipamente care permit transformarea energiei solare radiante n energie termic, adic permit, prin expunerea razelor solare pe aceste panouri, creterea temperaturii unui fluid (n general ap), din care, la rndul su, este posibil obinerea energiei pentru nclzirea utilizatorilor cum ar fi , de exemplu, boilerele, etc.
Lumina soarelui, alctuit din acest fascicul de unde electromagnetice, transport o cantitate de energie E pe suprafaa unui corp expus la soare; lungimile de und caracteristice luminii solare sunt cuprinse ntre 0,3 i 3. Aceast cantitate de energie E reprezint radiaia global incident pe o suprafa orizontal, care la rndul su este constituit din radiaia direct (care vine perpendicular de la soare) plus radiaia difuz (care vine din toate direciile cerului, i reprezint radiaia solar deviat de la traseul su direct i care ajunge pe suprafaa orizontal a corpului). Suprafaa unui corp, la rndul su, va putea: - S absoarb aceste radiaii solare cu un procent al energiei iniiale E; - S transmit aceste radiaii solare cu un procent al energiei iniiale E; - S reflecte aceste radiaii solare cu un procent al energiei iniiale E. Evident, suma radiaiilor absorbite / transmise / reflectate trebuie s fie egal cu radiaia incident originar, deci trebuie s ndeplineasc relaia + + = 100% De asemenea trebuie inut cont de faptul c aceti coeficieni / / sunt variabili n funcie de caracteristicile lungimii de und .
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
Geamul la rndul su nu va lsa s treac aceste ultime radiaii solare emise de la suprafaa opac (caracterizate de lungimea de und cuprins ntre 3 i 60), deoarece coeficientul su de transmisie va fi egal cu zero pentru lungimile de und ale radiaiilor emise de la suprafaa opac. Astfel, se va crea un efect de ser n interiorul panoului, deoarece radiaiile emise de la suprafeele opace sunt reflectate de geam i apoi absorbite.
4 Colector solar
Dac ne gndim s poziionm tuburile, cu partea interioar a fluidului termo - vector, n locul suprafeei opace, putem utiliza aceast modalitate pentru a ceda energia solar unui fluid, ducnd la creterea temperaturii acestuia: s-a creat astfel un colector solar. Legenda: 1. geam 2. tub 3. plac metalica 4. izolator termic 5. fluid termo - vector
Ansamblul suprafa opac alctuit din tub (prin care curge fluidul) i placa care conine acest tub constituie un schimbtor de cldur, energia care ptrunde n plac se transmite tubului, care la rndul su cedeaz energia fluidului termo vector. Energia solar E n mod experimental are valoarea de 1,4 kW/m2, dar aceast valoare e valabil pe suprafaa extern atmosferei, trebuie luate n considerare i pierderile date de latitudine, de anotimp i de starea vremii, care mpreun duc la diminuarea acestei energii.
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
6
.
ORA
Bolzano Milano Bologna Firenze Perugia Roma Napoli Cagliari Reggio Calabria Catania
N.B. pentru o instalare optim UTILIZARE ANUAL sau UTILIZARE PE TIMP DE VAR orientarea colectorului va fi spre SUD i nclinarea va trebui s fie egal cu valorile de mai sus: valorile energiilor solare Ei vor fi corecte n funcie de datele din tabelul urmtor: Localitate Utilizare Factor Multiplicativ de E Factor Multiplicativ de E (orientare spre EST sau VEST) ( orientare spre SUD) NORD ITALIA ANUAL 0,6 0,7 NORD ITALIA VAR 0,8 0,87 SUD ITALIA ANUAL 0,7 0,76 SUD ITALIA VAR 0,8 0,9
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
n schimb n schema urmtoare, reprezentarea colectorului solar MTS TOP, absorbitorul are o putere de absorbie mai mare, deci energia solar transmis Et (indicata cu A) poate fi de 95%, n timp ce partea de putere E1 primit dar nereinut scade pn la 5%: aceasta pentru c placa absorbant din cupru este tratat la suprafa cu TINOX.
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
Placa absorbant din cupru, care capteaz energia solar i o transmite conductelor prin care trece apa, este elementul fundamental pentru creterea eficienei colectorului solar. Eficiena unui colector poate fi determinat procentual de o diagram, unde se poate determina aceeai rezultant dat fiind valoarea parametrului salt termic T/ energie solar E. Saltul termic T este egal cu diferena T = (T medie plac T aer ambient) unde T medie plac poate fi aproximat la valoarea T medie plac = --------------------------------------------------2 i este dependent de tipul de absorbie, de cantitatea de energie solar radiant n acel moment (i deci de localitatea i de perioada de expunere). O astfel de valoare de input pentru determinarea randamentului (rezultat din diagrame), este deci o valoarea instantanee (adic diferit de la un moment la altul), o valoare medie de calcul experimental al Tmedie plac pentru o localitate din centrul Italiei, n mijlocul anotimpului, la miezul zilei, poate fi egal cu 50C. Oricum, dac nu ar fi posibil determinarea prin calcule a parametrului salt termic T/ energia solar E, de obicei se ia valoarea de randament maxim rezultant din diagrame. 5.1 Curba de randament colector solar standard T intrare
fluid
+ T ieire fluid
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
De exemplu, dac dorim s calculm eficiena panoului nostru amplasat la Milano i care funcioneaz pe toat perioada anului, vom avea urmtoarele date: T aer ambient = 13,8 C (temperatura medie anual) T medie plac = 50 C T = (T medie plac - T aer ambient) = 36,2C E= 2,5 kWh/ m2 zi (valoarea medie anual vezi tabelele anterioare) Ore de funcionare / zi medie = 8 h/ zi Panouri prezente = 1 cu suprafa util absorbant de 1,8 m2 (din datele de pe placa de timbru a panoului)
[ ]
Consultnd diagramele de mai sus, n cazul colectorului solar standard, vom avea o eficien instantanee de circa 30% i n cazul colectorului solar TOP, vom avea o eficien instantanee de circa 55%.
10
6.2 Instalaie cu circulaie natural Vom vedea o schema de maxim pentru un colector solar conectat la un boiler: boierul trebuie s fie mereu situat la un nivel mai nalt dect cel al colectorului. Pentru a evita supranclzirea la utilizare se recomand instalarea unui mixer (amestector) n partea de jos a rezervorului ntre tur i retur ap menajer.
Legenda: A) Intrare ap menajer B) Ap calda menajer ( pentru utilizare ) 1) Suport sond 2) Supap siguran boiler 3) Tur boiler 4) Robinet de umplere / evacuare (golire) colector (la golire deschidei supapa de siguran circuit colector) 5) Retur Boiler (servete pentru efectuarea conectrii la mai multe colectoare in serie) 6) Racord cu dop pentru efectuarea conectrii la mai multe colectoare in serie 7) Supap siguran circuit Colector (1,5bar)
6.3 Conectri n serie i n paralel Se poate efectua conectarea mai multor colectori n serie cnd numrul colectorilor ncepe de la 2 pn la 7: pentru un numr mai mare de 8 colectori se recomand conectarea n grupuri de cte 4. Diametrul tuburilor, recomandat: 18 mm (de la 2 la 4 colectori) / 22 mm (de la 5 la 7 colectori). Conectarea n serie se recomand atunci cnd se cere o capacitate limitat i o temperatura ridicat a apei menajere la utilizare. Legenda: A) Retur Boiler (Ap rece) B) Tur Boiler (Ap Cald)
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
11
Conectarea n paralel se recomand atunci cnd trebuie s se utilizeze o capacitate mare la o temperatura medie a apei menajere: trebuie s se in mereu cont de faptul c intrarea apei reci trebuie s treac prin toate colectoarele n acelai mod.
Legenda:
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
12
Legenda: A) Ap rece B) Ap cald 1) Central termica cu producere a.c.m. instantaneu 2) Valv nchis 3) Comand valv cu 3 ci 4) Termometru, termostat digital de control temperatura i comand valv cu 3 ci. 5) Sonda boiler 6.5 Aerisirea instalaiei cu circulaie natural La instalaia cu circulaie natural este necesar efectuarea unei aerisiri corecte a circuitului. Pentru aceast operaiune nu este suficient ca, n faza de umplere la rece a circuitului, s ias tot aerul de la supapa de siguran a circuitului colector, ci pentru siguran trebuie s se efectueze o umplere complet (la instalaia in regim de lucru ). 6.6 Dimensionarea instalaiei cu circulaie natural (instalaii mici casnice)
Vom evalua, pentru diferitele tipologii de instalaii cu circulaie natural, propunerile din catalogul de la MTS, datele pentru o prim dimensionare rapid i de maxim (imediat), apoi eventual efectund calculele exacte de verificare. De exemplu setm calculul pentru o instalaie solar 150/1 TOP: A) Date de pornire colector (din catalog): un colector solar TOP MTS Suprafa absorbant util 1,8 m2 Capacitate pe panou 100 lt/h B) Date de Proiect Localitate: Roma T aer ambient media anual = 15,9C (se poate lua din tabele UNI) Numr de ore/ zi media de funcionare panou = 8 h/ zi Persoane: 4
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
13
Salt termic mediu boiler T = 35C C) Formule de calcul dimensionare de maxim " Acumulare utilizator (acumulare) = 50 Lt / de persoana zi Acumulare necesar la boiler [Lt/zi] = Necesar utilizator * N persoane Numr panouri = 1 panou la fiecare 100 litri Acumulare la boiler Necesar energetic la Boiler = Necesar boiler * Salt termic D) Desfurare Calcule dimensionare de maxim Acumulare necesar la boiler = (50 Lt / persoana zi) * 4 (persoane) = 200 Lt/ zi Numr panouri = 2 Necesar energetic la Boiler = 200 Lt/ zi * 35C (T) = 7.000 kCal/ zi = 8,14 kWh/ zi E) Alegerea Boilerului de maxim Din datele reieite din dimensionarea de maxim, i anume: Acumulare necesar = 200 Lt/ zi Necesar energetic necesar la Boiler = 8,14 kWh/ zi Vom proceda la alegerea din catalog a boilerului cel mai adecvat, adic care s ndeplineasc cel mai bine condiiile dimensionrii de maxim: alegem un boiler MTS CNA1R DATE DE PE PLACA DE TIMBRU Producie ap n continuu (la T = 35) = 457 lt/h Putere (capacitate) max. ce poate fi absorbit de boiler (la T = 35) = 18,6 kW Verificarea de maxim este pozitiv F) Verificare proiect de maxim i calcule inginereti Mai nti fixm saltul termic ntre colector i boiler T. Saltul termic T este egal cu diferena T = (T medie plac - T aer ambient) unde T medie plac poate fi aproximat la valoarea T medie plac T intrare fluid + T ieire fluid
= ---------------------------------------------------
= 50 C
14
Acum putem calcula valoarea de input pentru a determina randamentul relativ din diagramele Curba de randament colector solar standard:
T / E =
Cu aceast valoare de input obinem din diagrama pentru un colector MTS TOP un randament de circa 45% Acum putem determina cantitatea medie Q pe care colectorul o d ca disponibil: kWh kWh 2 Q = E S = 0,45 3,34 2 1,8 m / pannello = 2,7 giornopannello m giorno
Numrul panourilor va fi dat de un astfel de necesar mprit la cantitatea medie de cldur Q pe care o d colectorul:
N pannelli =
Fabbisogno Q
8 ,14 = 3 pannelli 2 ,7
Acum vom determina alegerea boilerului adecvat: va trebui s calculm volumul Vb al boilerului care poate: Verificarea 1: s primeasc cantitatea de energie Q pe care o d colectorul; Verificarea 2: s furnizeze cantitatea de ap menajer necesar pentru consumul zilnic cerut V (cu T de 35C), verificnd dac Vb > V. Deci:
Verificarea 1
kWh Cantitatea de cldur Q pe care o d colectorul = 2,7 x 3 [panouri] = giornopannello kWh 8,1 giorno
Puterea max. absorbita (la T = 35) = 18,6 kW
Verificarea 2
Vom calcula consumul zilnic cerut V V = C ap menajer x Cc x H Cu: C ap menajer = consum zilnic necesar ap menajer [litri / zi] Tip de Alimentare Consum Zilnic [lt] Consum Zilnic la T = 35 [lt] Cada de baie 150 107 Du 50 36 Lavoar (igiena personal) 10 7
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
15
30 21
Cc = coeficient de simultaneitate (n funcie de numrul de utilizatori) Numr utilizatori 1 2 3 4 5 6 7 8 9 10 Coeficient Cc 1,15 0,86 0,73 0,65 0,60 0,56 0,53 0,50 0,48 0,47 H = ore de vrf cu max. cerere ap cald (locuine, hotel H=2, centre sportive H=1, restaurante H=3) Pentru calculul nostru cantitatea de ap menajer V necesar cererii de consum zilnic va fi: V = (150+10+30) [lt] x 0,73 x 2 = 277 lt. volumul Vb al boilerului poate fi ales din calculul urmtor: Vb = (producie ap boiler n primele 10 cu T de 35C) + H x (producie ap boiler n continuu cu T de 35C) Raportndu-ne la datele de pe placa de timbru a boilerului putem efectua urmtorul calcul Vb = (218 lt ) + 2 x (457 lt/h) = 1132 lt Deci am verificat dac Vb > V, deci boilerul ales MTS CNA1R ndeplinete condiiile cererii de consum zilnic de la utilizatori. 6.7 Instalaie cu circulaie forat La instalaiile cu circulaie forat ,un panou electronic de comanda si control prin sondele corespunztoare relev: - T = Tpartea de sus panou fluid - Tboiler sanitar la centrul schimbtorului, ntre temperatura de ieire ap colector (n partea de sus a panoului la ieirea apei calde sonda 3) i temperatura apei n interiorul boilerului (sonda 9); - temperatura de ieire ap menajer i eventuala comutare a valvei cu trei ci la circuitul de nclzire (sonda 8). Panoul electronic d confirmarea de pornire a pompei sau nu (linia 7) confruntnd T panou /boiler, cnd cldura produs cu ajutorul colectorului nu este suficient: pompa pornete cnd temperatura fluidului plus T prestabilit depete temperatura n interiorul boilerului. Aceast confruntare de temperaturi poate fi reglat ntr-un cmp de selecie de la 5 / 10 / 15 / 20 C, adic putem face pompa s porneasc cu o valoare T prestabilit i deci putem varia puterea furnizat la boiler n funcie de diferitele exigene. Valoarea T recomandabil este de 5 10 C, astfel nct s se stabileasc un echilibru ntre cantitatea de ap ce trebuie inut la temperatura (care nu trebuie s fie excesiv) i exigenele de confort ale utilizatorului. Cnd termostatul boilerului (sonda 8) sesizeaz c temperatura apei menajere este insuficient, comand valva cu trei ci (poziia 12) care comut trimiterea apei menajere n circuitul centralei (poziia 14 i 15). Atenie: Dimensionarea numrului i poziiei colectoarelor este aceeai ca i cea de la instalaiile cu circulaie natural, se schimb proiectul nivelului de amplasare. De exemplu, s vedem componentele principale ale unei instalaii solare 150/1 TOP cu circulaie forat:
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
16
Legenda: 1. colectori solari 2. dezaerator 3. Sonda temperatura colector 4. Grup de circulaie 5. Vas de expansiune 6. Panou electronic 3 sonde 7. Alimentare 220V 8. Sonda ieire ap cald menajer (on/off valva cu trei ci)
Sonda temperatura boiler Mixer termostatic Boiler solar cu serpentin Valva comutatoare cu trei ci Intrare ap rece Ieire ap cald menajer Centrala termica Alimentare circuit solar
6.8 Aerisire instalaie cu circulaie forat La instalaia cu circulaie forat este necesar efectuarea unei aerisiri corecte a circuitului: Pentru a face acest lucru este necesar instalarea valvei dezaeratoare obligatoriu n partea de sus a circuitului. De asemenea trebui scos complet aerul, n urmtoarele moduri:( vezi schema de mai jos ) - Deschiznd valva corespunztoare a dezaeratorului 7 (la terminarea procesului de aerisire); - Acionnd asupra tabloului electronic n care este instalat pompa n modul urmtor: 1. umplei instalaia la rece cu ajutorul pompei externe i efectuai prima aerisire cu ajutorul valvei dezaeratoare; 2. nchidei valva anti-retur 2; 3. umplei instalaia cu ajutorul robinetului amplasat sub valva de siguran 9 ; 4. deschidei robinetul de evacuare - ncrcare 12 (se efectueaz evacuarea aerului); 5. redeschidei valva anti-retur 2 i nchidei robinetele deschise anterior.
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
17
Legenda: 1. valva cu sfera; 2. valva cu sfera anti-retur (montata pe tur ) 3. tu ; 4. valva nchidere retur panouri 5. valva nchidere tur ap cald din panouri ctre boiler; 6. termometru temperatura; 7. dezaerator; 8. izolaie PPE; 9. supapa de siguran 6 bar; 11. racord pompa; 12. robinet umplere /golire 13. Pompa circulaie solar 14. manometru 15. racord filet pentru vas expansiune
6.9 Vas de expansiune La instalaiile cu circulaie forat trebuie s se efectueze o dimensionare corect a vasului de expansiune, valorile recomandabile sunt: 12 / 15 litri = pn la un nr. de 3 colectori 18 litri = pn la un nr. de 6 colectori 24 litri = pn la pn la 13 panouri. Dac ar fi necesar un calcul exact al volumului nominal al vasului de expansiune, aceast valoare ar putea fi calculat cu ajutorul formulei: eC V = 1 Pi Pf unde: V = capacitatea vasului; C = coninutul de ap n instalaie = Coninut colector (2 lt)+ Coninut evi (de calculat) + Coninut serpentine (spirale) / spaii boiler (CNA1R = 17 lt. CNA2R = 22 lt); e = coeficient de expansiune (egal cu 0,049 pentru temperaturile atinse n colectori pn la 110C); Pi = presiune de ncrcare instalaie (1,5 bar); Pf = presiune de evacuare supapa de siguran (8 bar). 6.10 Pompa n continuare este prezentat diagrama debit / sarcina a pompei instalat pe grupul de instalatie MTS. Pentru o dimensionare corect trebuie s se in seama de capacitatea unui panou care este de circa 100 lt/h: astfel va putea fi setat viteza corect a pompei de recirculare n funcie de capacitatea rezultat. Va trebui s se ia n consideraie urmtoarele: - Dac se alege un nivel sczut de turatie a pompei, consumul electric va fi mai mic, dar exist riscul ca n interiorul circuitului s apar mari pierderi (scpri) termice rezultnd astfel randamente mici; - Dac se alege un nivel ridicat de turatie a pompei, consumul electric ar putea fi n mod inutil mare
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
18
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
19
7.3 Racordrile circuitului colector Trebuie racordat pompa, vasul de expansiune, valva antiretur (grupul (3)) pe linia de retur a colectorului (1); nu trebuie s existe ntreruperi ntre colector i vasul de expansiune / supapa de siguran. De asemenea, se recomand racordarea vasului de expansiune n partea de sus, n aa fel nct s se protejeze membrana de eventualele supranclziri ale fluidului. Ventilul (valva dezaeratoare (2)) va fi nfiletat n punctul cel mai de sus al circuitului colectorului, la ieirea turului colectorului, etaneiznd evile cu racorduri (4). n schimb, robinetele de umplere a circuitului colectorului trebuie s fie instalate n punctul cel mai de jos al circuitului colectorului.
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
20
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
21
4- Umplerea circuitului (CIRCULAIE NATURAL) Deschidei supapa de siguran amplasat deasupra boilerului; Umplei cu soluie de ap i glicol (n proporie calculat n funcie de temperaturile externe) n modul cu gravitaie (rezervorul de soluie situat deasupra boilerului n punctul cel mai nalt al circuitului), racordnd tubul de ncrcare la robinetul de umplere al instalaiei. Umplerea instalaiei se va face n mod natural pn cnd supapa de siguran va ncepe s picure: dup aceasta, nchidei supapa de siguran i robinetele pentru a termina ncrcarea (umplerea).
5- Scoaterea aerului din circuit : o dat umplut corect circuitul, instalaia trebuie setat pe regim de functionare i trebuie s se scoat aerul de la valva dezaeratoare, aceast operaiune va trebui repetat de mai multe ori , n mai multe zile pentru a fi siguri c a fost scos tot aerul (vezi i capitolul precedent). 6- Umplei circuitul boilerului: dup ce ai efectuat operaiunile descrise mai sus, deschidei robinetul de umplere intrare ap rece i umplei boilerul pn cnd de la un robinet de utilizare nu mai iese ap.
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
22
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro
23
MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro