IBM System Storage SAN24B-4 Express
IBM System Storage SAN24B-4 Express
Read Before Using This product contains software that is licensed under written license agreements. Your use of such software is subject to the license agreements under which they are provided.
GA32-0580-02
GA32-0580-02
Note: Before using this information and the product it supports, read the information in Notices on page 39.
Copyright 2008-2010 Brocade Communications Systems, Inc. All Rights Reserved. The following paragraph does not apply to any country (or region) where such provisions are inconsistent with local law. INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states (or regions) do not allow disclaimer of express or implied warranties in certain transactions; therefore, this statement may not apply to you. Copyright IBM Corporation 2008, 2010. US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Summary of changes
This is the third edition of the IBM System Storage SAN24B-4 Express Installation, Service, and User Guide. The content changes since the last edition of this publication are noted by a vertical line placed in the left margin beside each change. Minor edits are not identified by this mark. A summary of the changes for each edition are listed below.
Third edition
The following changes were made in the third edition: v Addition of information about the Server Application Optimization (SAO) optional feature v A change to the Fabric Operating System (FOS) required version v Update of environmental notices v Reorganization of general information, including the addition of the Read This First section v Update of the Notices section v Update of how to submit reader comments
Second edition
The following changes were made in the second edition: v Corrections to LED status tables
Getting help
For the latest version of your product documentation, visit the web at www.ibm.com/e-business/linkweb/publications/servlet/pbi.wss?. Search by form number or title. For more information about IBM SAN products, see the following Web site: www.ibm.com/servers/storage/san/ | | | | For support information for this product and other IBM products, see the following Web site: www.ibm.com/systems/support/supportsite.wss/. Select System Storage. On the next page, select your product family, and then select the specific product. You can also contact IBM within the United States at 1-800-IBMSERV (1-800-426-7378). For support outside the United States, you can find the service number at: www.ibm.com/planetwide/. Visit www.ibm.com/contact for the contact information for your country or region. For detailed information about the Fibre Channel standards, see the Fibre Channel Industry Association (FCIA) Web site at: www.fibrechannel.org/ For information about storage industry standards, see the Storage Networking Industry Association (SNIA) Web site at: www.snia.org/
Copyright IBM Corp. 2008, 2010
iii
Accessibility features
The following list includes the major accessibility features in this product: v Light emitting diodes (LEDs) that flash at different rates, to represent the same information as the colors of the LEDs v Industry-standard devices for ports and connectors v Management of the product through management applications is available through Web and Graphical User Interface (GUI) options
Keyboard navigation
This product does not have an attached or integrated keyboard. Any keyboard navigation is provided through the management software and GUI.
Vendor software
This product includes certain vendor software that is not covered under the IBM license agreement. IBM makes no representation about the accessibility features of these products. Contact the vendor for the accessibility information about its products.
iv
v Exact publication title v Form number (for example, GC27-2270-00) v Page numbers to which you are referring You can also mail your comments to: International Business Machines Corporation Information Development Department GZW 9000 South Rita Road Tucson, Arizona 85744-0001 U.S.A. When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you.
vi
Contents
Read this first . . . . . . . . . . . . iii
| Summary of changes . . . . . . . . . . . iii Third edition . . . . . . . . . . . . . iii | Second edition . . . . . . . . . . . . iii |
Getting help . . . . . . . . . Taiwan Contact Information . . . Accessibility features for the SAN26B-4 Accessibility features . . . . . Keyboard navigation . . . . . Vendor software . . . . . . . Related accessibility information . IBM and accessibility . . . . . How to send your comments . . . . . . . . . Express . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii iv iv iv iv iv iv iv iv Creating a serial connection . Setting the switch IP address Setting the date and time . . . . . . . . . . . . . . . . . . . . . 17 . 17 . 18
Notices . . . . . . . . . . . . . . 39
Trademarks . . . . . . . . . . . . . . Electronic emission notices . . . . . . . . . Federal Communications Commission (FCC) Class A Statement . . . . . . . . . . . Industry Canada Class A Emission Compliance Statement . . . . . . . . . . . . . . Avis de conformit la rglementation d'Industrie Canada . . . . . . . . . . . European Union EMC Directive Conformance Statement . . . . . . . . . . . . . . Germany Electromagnetic Compatibility Directive People's Republic of China Class A Electronic Emission Statement . . . . . . . . . . . Japan VCCI Council Class A Statement . . . . Japan Electronics and Information Technology Industries Association (JEITA) Statement . . . Korea Communications Commission (KCC) Statement . . . . . . . . . . . . . . Russia Electromagnetic Interference (EMI) Class A Statement . . . . . . . . . . . . . Australia and New Zealand Class A Statement 41 42 42 42 42 42 43 44 44 45 45 45 45
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . .
. 7 . 8 . 8 . 8 . 8 . 9 . 9 . 10 . 10 . 10 . 15 . 16 . 16 . 16
Index . . . . . . . . . . . . . . . 47 vii
viii
Figures
1. 2. 3. 4. 5. Port side of the switch . . . . . . . . . 2 Trunking groups . . . . . . . . . . . 4 Rack assembly . . . . . . . . . . . 11 Separating the inner and outer rails . . . . 12 Mounting the moving portion of the slide and mounting brackets to the switch . . . . . 13 6. 7. 8. 9. 10. Mounting the fixed portion of the rail and the locking brackets to the rack . . . . . . Inserting slides into the rack rails . . . . Detailed view, location of LEDs on the switch SFP installation and bail closing. . . . . Removing an SFP . . . . . . . . . . 14 . 15 22 . 27 . 28
ix
Tables
1. 2. 3. 4. 5. 6. Brocade and IBM product and model number matrix . . . . . . . . . . . . . . xiv Sample caution notices . . . . . . . . xviii Parts supplied with the rack-mount kit 11 Power status LED patterns, status, and recommended actions . . . . . . . . . 23 System status LED patterns, status, and recommended actions . . . . . . . . . 23 Port LED patterns during normal operation 24 7. 8. 9. 10. 11. 12. 13. 14. 15. Ethernet LED patterns . . . . . . Management options for the switch . Physical dimensions and weight of the Environmental requirements . . . . Facility requirements . . . . . . General specifications . . . . . . Memory specifications . . . . . . Data transmission ranges . . . . . Switch power supply specifications . . . . . switch . . . . . . . . . . . . . 25 . 30 33 . 33 . 34 . 35 . 35 . 36 . 36
xi
xii
| | |
Product documents
| | | | | | | | | | | | | | | The following documents contain information related to this product. The documentation may be printed material or may be on the documentation CD that is shipped with the product. Newer versions of product documentation may be available through the IBM Publications Center Web site http://www.ibm.com/ebusiness/linkweb/publications/servlet/pbi.wss. Newer versions may also be available through the IBM Systems Support Web site www.ibm.com/systems/ support/supportsite.wss/. Select your product family, then the specific product, and then select Documentation. v IBM System Storage SAN24B-4 Express Installation, Service, and User's Guide, GA32-0580 (this document) v IBM System Storage SAN24B-4 Express Quick Start Guide GA32-0585 v IBM System Storage SAN24B-4 Express Access Gateway Quick Start Guide GA32-0588 v IBM Systems Safety Notices, G2299054 v IBM Warranty
Brocade documents
IBM b-type switches use software licensed from Brocade Communications Systems, Inc. You can find information related to the software that supports the director in the following documents on the CD-ROM supplied with this product: Brocade Fabric OS v v v v Fabric Fabric Fabric Fabric OS OS OS OS Administrator's Guide Command Reference Manual MIB Reference Manual Message Reference Manual
xiii
v v v v
Fabric OS Troubleshooting and Diagnostics Guide Access Gateway Administrator's Guide EZSwitchSetup Administrator's Guide SAN Glossary
Brocade Fabric OS optional features v Fabric Watch Administrator's Guide v Web Tools Administrator's Guide | | Brocade HBA publication v Brocade Adapters Administrators Guide
xiv
The following notices and statements are used in IBM documents. They are listed below in order of increasing severity of potential hazards. Follow the links for more detailed descriptions and examples of the danger, caution, and attention notices in the sections that follow. v Note: These notices provide important tips, guidance, or advice. v Attention notices on page xix: These notices indicate potential damage to programs, devices, or data. v Caution notices on page xvii: These statements indicate situations that can be potentially hazardous to you. v Danger notices: These statements indicate situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these situations. v In addition to these notices, Safety labels on page xix may be attached to the product to warn of potential hazards.
Danger notices
A danger notice calls attention to a situation that is potentially lethal or extremely hazardous to people. A lightning bolt symbol accompanies a danger notice to represent a dangerous electrical condition. Read and comply with the following danger notices before installing or servicing this device.
DANGER To prevent a possible shock from touching two surfaces with different protective ground (earth), use one hand, when possible, to connect or disconnect signal cables. (D001)
DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device or the power rating label for electrical specifications. (D002)
DANGER If the receptacle has a metal shell, do not touch the shell until you have completed the voltage and grounding checks. Improper wiring or grounding could place dangerous voltage on the metal shell. If any of the conditions are not as described, STOP. Ensure the improper voltage or impedance conditions are corrected before proceeding. (D003)
xv
DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (D004)
The following general electrical danger notice provides instructions on how to avoid shock hazards when servicing equipment. Unless instructed otherwise, follow the procedures in the following danger notice.
xvi
DANGER When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. v Do not open or service any power supply assembly. v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. v Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate. v Connect any equipment that will be attached to this product to properly wired outlets. v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described below when installing, moving, or opening covers on this product or attached devices. To disconnect: 1. Turn off everything (unless instructed otherwise). 2. Remove the power cords from the outlets. 3. Remove the signal cables from the connectors. 4. Remove all cables from the devices. To connect: 1. Turn off everything (unless instructed otherwise). 2. Attach all cables to the devices. 3. Attach the signal cables to the connectors. 4. Attach the power cords to the outlets. 5. Turn on the devices. (D005)
Caution notices
A caution notice calls attention to a situation that is potentially hazardous to people because of some existing condition. A caution notice can be accompanied by different symbols, as in the examples below:
About this document
xvii
Table 2. Sample caution notices If the symbol is... It means.... A hazardous electrical condition with less severity than electrical danger. A generally hazardous condition not represented by other safety symbols. A specification of product weight that requires safe lifting practices. The weight range of the product is listed below the graphic, and the graphic and the wording of the caution varies, depending on the weight of the device. A potential hazard of pinching the hand or other body parts between parts.
P/N 18P5850-B
SJ000752
svc00167
A hazardous condition due to the use of a laser in the product. Laser symbols are always accompanied by the classification of the laser as defined by the U. S. Department of Health and Human Services (for example, Class I, Class II, and so forth).
Read and comply with the following caution notices before installing or servicing this device.
CAUTION: Energy hazard present. Shorting may result in system outage and possible physical injury. Remove all metallic jewelry before servicing. (C001) CAUTION: This part or unit is heavy but has a weight smaller than 18 kg (39.7 lb). Use care when lifting, removing, or installing this part or unit. (C008) CAUTION: This product is equipped with a 3-wire (two conductors and ground) power cable and plug. Use this power cable with a properly grounded electrical outlet to avoid electrical shock. (C018) CAUTION: Servicing of this product or unit is to be performed by trained service personnel only. (C032)
xviii
Safety labels
As an added precaution, safety labels are often installed directly on products or product components to warn of potential hazards. These can be either danger or caution notices, depending upon the level of the hazard. The actual product safety labels may differ from these sample safety labels:
DANGER Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001)
DANGER Rack-mounted devices are not to be used as a shelf or work space. (L002)
DANGER Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
DANGER Hazardous voltage present. Voltages present constitute a shock hazard, which can cause severe injury or death. (L004)
Attention notices
An attention notice indicates the possibility of damage to a program, device, or system, or to data. An exclamation point symbol may accompany an attention notice, but is not required. A sample attention notice follows: Attention: Do not bend a fibre cable to a radius less than 5 cm (2 in.); you can damage the cable. Tie wraps are not recommended for optical cables because they can be easily overtightened, causing damage to the cable.
xix
Rack safety
Rack installation
DANGER Observe the following precautions when working on or around your IT rack system: v Heavy equipmentpersonal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet. Always install servers and optional devices starting from the bottom of the rack cabinet. v Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices.
v Each rack cabinet might have more than one power cord. Be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. v Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet. Do not plug a power cord from a device installed in one rack cabinet into a power device installed in a different rack cabinet. v An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock.
(R001 part 1 of 2) CAUTION: v Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturers recommended ambient temperature for all your rack-mounted devices. v Do not install a unit in a rack where the air flow is compromised. Ensure that air flow is not blocked or reduced on any side, front, or back of a unit used for air flow through the unit. v Consideration should be given to the connection of the equipment to the supply circuit so that overloading of the circuits does not compromise the supply wiring or overcurrent protection. To provide the correct power connection to a rack, refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit. v (For sliding drawers) Do not pull out or install any drawer or feature if the rack stabilizer brackets are not attached to the rack. Do not pull out more than one drawer at a time. The rack might become unstable if you pull out more than one drawer at a time. v (For fixed drawers) This drawer is a fixed drawer and must not be moved for servicing unless specified by the manufacturer. Attempting to move the drawer partially or completely out of the rack might cause the rack to become unstable or cause the drawer to fall out of the rack. (R001 part 2 of 2)
xx
xxi
| | | | |
xxii
v v v
logical ISL switch with a speed of up to 64 Gbits/sec (128 Gbits/sec full duplex) for optimal bandwidth utilization and load balancing. Advanced Zoning. Intelligent management and monitoring with Web Tools, Fabric Watch, and Performance Monitor. Adaptive Networking Services uses network intelligence to anticipate congestion and to dynamically make adjustments in the fabric so that application traffic continues to flow Dynamic Path Selection (DPS) optimizes fabric-wide performance and load balancing by automatically routing data to the most efficient available path in the fabric.
v Light emitting diodes (LEDs) to indicate system power, system status, Ethernet speed and link status, and port status.
Supported connectivity
Specific details on supported operating systems, servers, and devices, storage products attachability, SAN connectivity products, and configuration options can be found in the interoperability matrices at the following web site: www.ibm.com/servers/storage/support/san.
1
Figure 1. Port side of the switch Item number 1 2 3 4 5 6 7 Description System status (top) and power (bottom) LEDs System RS232 console port (RJ-45) Ethernet Port with two Ethernet status LEDs USB port Fibre Channel status LEDs Fibre Channel Ports (24) AC power receptacle
B24_0001
B A
B24_0002
B
Figure 2. Trunking groups
v ATrunk Group 1: ports 0 through 7 v BTrunk Group 2: ports 8 through 15 v CTrunk Group 3: ports 16 through 23 Note: ISL Trunking is optional software that allows you to create trunking groups of ISLs between adjacent switches. For more information about trunking, refer to the Fabric OS Administrators Guide.
| |
In addition, customers can order a set of optional features bundled into one orderable feature, the B24 Enterprise Package. This bundled feature consists of one of each of Fabric Watch, Trunking Activation, Advanced Performance Monitor, Adaptive Networking, and two 8-Port Activations.
For more information on the use of these features, refer to the Fabric OS Administrators Guide.
The switch can be installed either as a free-standing unit, or installed in an EIA cabinet, using an optional slide-rail rack mount kit. When mounting into a slide-rail rack, you can mount the chassis to slide from either the port side or the nonport side.
Electrical considerations
To install and operate the switch successfully, ensure the following: v The primary outlet is correctly wired, protected by a circuit breaker, and grounded in accordance with local electrical codes. v The supply circuit, line fusing, and wire size are adequate, as specified by the electrical rating on the switch nameplate. v The power supply standards provided in Power supply specifications on page 36 are met.
Environment considerations
For successful installation and operation of the switch, ensure that the following environmental requirements are met: v At a minimum, adequate cooling requires that you install the switch with the nonport side, which contains the air intake vents, facing the cool-air aisle. v All equipment in the rack should force air in the same direction to avoid intaking exhaust air. v A minimum of 680 l/min (24 cubic ft/min) of air flow is available to the air intake vents on the nonport side of the switch. v The ambient air temperature does not exceed 40 C (104 F) while the switch is operating.
Cabinet considerations
Attention: See Rack safety on page xx for danger and caution notices related to product installations in racks or cabinets. For successful installation and operation of the switch in a cabinet, ensure that the following cabinet requirements are met: v The cabinet must be a standard EIA cabinet.
v Plan a cabinet space that is 1 rack unit 4.45 cm (1.75 in.) high, 48.3 cm (19 in) wide. v Ground all equipment in the cabinet through a reliable branch circuit connection and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip. v Ensure that airflow and temperature requirements are met on an ongoing basis, particularly if the switch is installed in a closed or multicabinet assembly. v Verify that the additional weight of the switch does not exceed the cabinets weight limits or unbalance the cabinet in any way. v Secure the cabinet to ensure stability in case of unexpected movement, such as an earthquake.
Attention: Refer to Rack safety on page xx for danger and caution notices related to rack and cabinet installations. You can install the rack mount kit in either of two ways: v To allow the port side of the switch to slide out of the exhaust-air side of the cabinet. In this installation, the port side of the switch is flush with the edge of the cabinet.
v To allow the non-port side of the switch to slide out the cool-air side of the cabinet. In this installation, the port side of the switch is set 7.62 cm (3 in.) back from the edge of the cabinet, allowing a more gradual bend in the fiber optic cables.
Time required
Approximately 30 minutes
Items required
You need the following items to install the switch in a slide-rail rack: v Straight slot screwdriver v Rack space: 1 EIA unit of rack space, 48.3 cm (19 in.) wide, and 60.96 cm (24 in.) deep v One power cord that is provided with the switch v One power outlet v Rack mount kit Attention: Use the exact screws specified in the procedure for use with the switch chassis. Using screws longer than 3/16 in. can damage the switch. The different types of screws are listed in Table 3 on page 11. Note: Make sure that you tighten all screws used in this procedure.
Installation instructions
To install the switch in a slide-rail rack that meets EIA standards, use the following procedure. Note: These procedures use parts that are included in the rack-mount kit. These parts are listed in Table 3 on page 11. The installation procedure cross-references the items in this table. Be sure to use the referenced parts when you perform each step. Before you start the rack-mount installation process, locate the rack-mount slides and the mounting bracket that are provided in the shipping container. Figure 3 on page 11 shows the rack assembly. The number keys, such as 1 , refer to the items listed in Table 3 on page 11.
10
4
4X
9
Outer Slide EIA Rack Rail 8X
7
4X
Inner Slide
1
2X
See Detail A
5 7 3
Front of Switch 4X 4X
10
8X
11
8X
6
5X
12
8X
6
2X
7
2X
Detail A
SJ000153
1. Unpack the rack-mount kit and verify that all ordered items and parts are present and undamaged. See Table 3 for a list of parts and the quantities supplied.
Table 3. Parts supplied with the rack-mount kit Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Rack mount slide (inner and outer slide) Right rack mount bracket (optional bracket for front of switch) Left rack mount bracket (optional bracket for front of switch) Rack mounting bracket (3-hole) Nut clip, M5 Screw, 8-32 x 3/16 in., zinc Screw, M5 x 12 Bracket to slide rack kit (contains items 9 12) Screw, 8-32 x 3/8 in., zinc Washer, flat, No. 8 Washer, lock, No. 8 Nut, hex, 8-32 Quantity 2 1 1 4 11 11 11 1 5 5 5 5
11
2. Separate the inner and outer slides. a. Open one of the slides until the lock engages. b. Press the lock release lever ( 1 in Figure 4) and remove the inner rail from the outer rail.
SJ000046
c. Repeat step 2a and step 2b for the other rail. Note: For racks with flush-mount doors, such as the 9306 Netfinity racks, do not install the front brackets. Instead, use the rack-mount slides by attaching the switch to the set of mounting holes, which are offset 3 inches into the rack. 3. Install the inner (smaller) slide on the switch chassis, as Figure 3 on page 11 shows. Attention: If you use screws longer than 3/16 in., you can damage the switch. a. Position the flat side of the inner rail along one side of the switch. Align the holes in the rail with the threaded holes in the side of the switch chassis. The chamfered end of the inner rail should face toward the rear of the switch (away from the ports) as shown in Figure 5 on page 13. b. Attach the inner rail by using three of the 8-32 x 3/16 in. zinc screws ( 6 in Table 3 on page 11).
12
Front
Figure 5. Mounting the moving portion of the slide and mounting brackets to the switch
SJ000047
c. Repeat step 3a on page 12 and step 3b on page 12 for the second inner rail on the other side of the switch chassis. 4. Optional step: If desired, install the right rack mount bracket 2 (see Figure 3 on page 11) and the left rack mount bracket 3 on the switch chassis. Use these brackets to secure the switch to the rack as shown in Figure 5. Attention: Do not use screws longer than 3/16 in.; they can damage the switch. a. Position the left rack mount bracket at the left front corner of the switch chassis. Align the two holes in the bracket with the two threaded holes in the switch chassis. b. Attach the bracket by using two of the 8-32 x 3/16 in. zinc screws (see 6 in Figure 3 on page 11) c. Repeat step 4a and step 4b for the right rack mount bracket on the right front corner of the switch chassis. 5. Attach all four of the 3-hole rack mounting brackets 4 in Figure 6 on page 14. a. Position a 3-hole rack mounting bracket 4 at the end of one of the outer slides. b. Attach the bracket by using the 8-32 x 3/8 in. zinc screws 9 . Ensure that the screw heads are inside the slides. c. Place one each of the following items on the outer end of the screw in the order listed: 1) Washer, flat No. 8 10 2) Washer, lock No. 8 11 3) Nut, hex, 8-32 12 d. Repeat steps 5a through 5c for the three remaining rail ends.
13
12 11 10
4 3
SJ000048
Figure 6. Mounting the fixed portion of the rail and the locking brackets to the rack
6. Install the outer (larger) slides in the rack, as shown in Figure 6. a. At the desired height, install the five M5 nut clips 5 . Put three M5 nut clips in the front of the rack and two in the back. The middle clip in the front of the rack is for the locking ears. Note: Some rack mount kits might use 10-32 nut clips in place of the M5 nut clips for the locking ears. b. Attach the slides by using four M5 x 12 screws 7 (see Figure 3 on page 11). c. Repeat step 6a and step 6b for the other rail. 7. Install the switch in the rack. a. Position the switch in front of the rack. Insert the switch into the rack by sliding the inner slides that are mounted on the switch into the outer slides that are mounted on the rack. See Figure 7 on page 15.
14
SJ000049
b. Check the alignment of the slides by sliding the switch in and out of the rack. Any difficulty moving the switch indicates lateral stress or misalignment. If this situation occurs, adjust the slide positions until the movement is smooth. 8. Optional step: If the right and left rack mount brackets are installed on the front corners of the switch, attach both brackets to the cabinet rack by using M5 x 12 screws 7 . See step 4 on page 13 and Figure 3 on page 11. The screws should pass through the front of each bracket and the slide rail. Note: Some rack mount kits might use 10-32 nut clips in place of the M5 nut clips for the locking ears. 9. Continue with initial setup of the switch by following the procedures in Configuring the switch on page 16.
DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (D004)
Note: Do not connect the switch to the network until you perform one of the following steps: v Set the internet protocol (IP) address. v Verify that the default IP address does not conflict with the existing IP addresses in the same network.
15
Cables can be organized and managed in a variety of ways: for example, using cable channels on the sides of the cabinet or patch panels to minimize cable management. Following is a list of recommendations: v Plan for rack space required for cable management before installing the switch. v Leave at least 1 meter (3.28 ft) of slack for each port cable. This provides room to remove and replace the switch, allows for inadvertent movement of the rack, and helps prevent the cables from being bent to less than the minimum bend radius. v If you are using Brocade ISL Trunking, consider grouping cables by trunking groups. The cables used in trunking groups must meet specific requirements, as described in the Fabric OS Administrator's Guide. v For easier maintenance, label the fiber optic cables and record the devices to which they are connected. v Keep LEDs visible by routing port cables and other cables away from the LEDs. v Use hook-and-loop fasteners to secure and organize fibre optic cables. Do not use tie wraps on fiber optic cables, because wraps are easily overtightened and can damage the optic fibers.
16
2. After POST is complete, verify that the switch power and status LEDs on the left of the port side of the switch are green.
v In a UNIX environment, type the following string at the prompt: tip /dev/ttyb -9600 If ttyb is already in use, use ttya instead and enter the following string at the prompt: tip /dev/ttya -9600
Using DHCP
When using DHCP, the switch obtains its IP address, subnet mask, and default gateway address from the DHCP server. The DHCP client can only connect to the a DHCP server that is on the same subnet as the switch. If your DHCP server is not on the same subnet as the switch, use a static IP address.
If you are going to use an IPv6 address, enter the network information in semicolon-separated notation as prompted.
17
switch:admin> ipaddrset -ipv6 --add 1080::8:800:200C:417A/64 IP address is being changed...Done. 3. Complete the rest of the network information as prompted. Ethernet Ethernet Ethernet 4. Enter off Subnetmask: [255.255.255.0] IP Address: [192.168.74.102] Subnetmask: [255.255.255.0] to Disable DHCP when prompted.
18
The time zone setting has the following characteristics: v You can view the time zone settings. However, only those with administrative permissions can set the time zones. v The tsTimeZone setting automatically adjusts for Daylight Savings Time. v Changing the time zone on a switch updates the local time zone setup and is reflected in local time calculations. v By default, all switches are in the GMT time zone (0,0). If all switches in a fabric are in one time zone, it is possible for you to keep the time zone setup at the default setting. v System services that have already started will reflect the time zone changes only after the next reboot. v Time zone settings persist across failover for high availability. The following procedure describes how to set the time zone for a switch. You must perform the procedure on all switches for which the time zone must be set. However, you only need to set the time zone once on each switch, because the value is written to nonvolatile memory. 1. If you are not already logged into the switch; do so now using the default password, which is password. 2. Enter the tsTimeZone command as follows: switch:admin> tstimezone [--interactive]/ [, timezone_fmt] Use timezone_fmt to set the time zone by Country/City or by time zone ID, such as PST. The following example shows how to display the current time zone setup and how to change the time zone to US/Central. switch:admin> tstimezone Time Zone : US/Pacific switch:admin> tstimezone US/Central switch:admin> tstimezone Time Zone : US/Central The following procedure describes how to set the current time zone using interactive mode to Pacific Standard Time. 1. Type the tsTimeZone command as follows:
switch:admin> tstimezone --interactive
3. Enter the appropriate number or Ctrl-D to quit. 4. At the prompt, select a country location. 5. At the prompt, enter the appropriate number to specify the time zone region or Ctrl-D to quit.
19
All switches in the fabric maintain the current clock server value in non-volatile memory. By default, this value is the local clock server <LOCL> of the principal or primary FCS switch. Changes to the clock server value on the principal or primary FCS switch are propagated to all switches in the fabric. For more information on using an NTP server, and IPv6 considerations, see the Fabric OS Administrators Guide. 1. If you are not already logged into the switch; do so now using the default password, which is password. 2. Enter the tsClockServer command:
switch:admin> tsclockserver "<ntp1;ntp2>"
where ntp1 is the IP address or DNS name of the first NTP server, which the switch must be able to access. The second ntp2 is the second NTP server and is optional. The operand <ntp1;ntp2> is optional; by default, this value is LOCL, which uses the local clock of the principal or primary switch as the clock server. The tsClockServer command accepts multiple server addresses in either IPv4, IPv6, or DNS name formats. When multiple NTP server addresses are passed, tsclockserver sets the first obtainable address as the active NTP server. The rest will be stored as backup servers that can take over if the active NTP server fails. The principal or primary FCS switch synchronizes its time with the NTP server every 64 seconds. switch:admin> tsclockserver LOCL switch:admin> tsclockserver "132.163.135.131" switch:admin> tsclockserver 132.163.135.131 switch:admin> The following example shows how to set up more than one NTP server using a DNS name: switch:admin> tsclockserver "10.32.170.1;10.32.170.2;ntp.localdomain.net" Updating Clock Server configuration...done. Updated with the NTP servers Changes to the clock server value on the principal or primary FCS switch are propagated to all switches in the fabric.
20
21
LED locations
All the switch LEDs are located on the port side. Figure 8 shows the location of individual LEDs
F A E B C D
Figure 8. Detailed view, location of LEDs on the switch Item A B C D E F LED names and descriptions System power LED (green) System status LED (green/amber) Ethernet link status LED Ethernet link speed LED Port status LED for port 3 Port status LED for port 7
22
B24_0003
LED patterns
Table 4 through Table 7 on page 25 summarize the switch LED locations, color, and meaning, as well as any recommended user response.
Steady green
Switch is off, boot is Verify that switch is not complete, or boot on and has failed. completed booting. Switch is operational. No action is required. One or both of the following are true: One or more environmental ranges are exceeded. Error log contains one or more port diagnostic error messages. Switch is faulty, or initializing. Check environmental conditions, error log, Port Status LEDs, SFPs, cables, and loopback plugs. Correct error condition. Clear error log. Rerun diagnostics to verify fix. Wait a few moments to verify that the switch is not initializing.
Amber
23
Table 6. Port LED patterns during normal operation LED name Port status LED color No light Status of hardware No light or signal carrier (SFP or cable) detected. Port is online (connected to external device) but has no traffic. Port is online but segmented, indicating a loopback cable or incompatible switch. Recommended action Check SFP and cable.
Steady green
No action is required.
Verify that the correct device is connected to the port and that the switch and port settings are correct.
Fast-flashing green (on 1/4 second, off 1/4 second) Flickering green
Port is in internal No action is required. loopback (diagnostic). Port is online, with traffic flowing through port. No action is required.
Steady amber
Port is receiving light No action is required. or signal carrier but is not yet online. Port is disabled as the result of diagnostics or portDisable command. If all ports are slow-flashing amber, the switch could be disabled. If all ports are slow-flashing amber, the switch could be disabled. Enable the port using the portEnable command; refer to Fabric OS Command Reference Manual for more information. If all ports are slow-flashing amber, enable the switch (switchEnable command). Check the Port Status LEDs, error log, SFP, and cable or loopback plug. Clear the error log. Rerun the diagnostics to verify that the error condition is fixed.
Port is faulty.
24
| | | | | |
No light
POST
The success or failure results of the diagnostic tests that run during POST can be monitored through the error log or the command line interface. POST includes the following steps: 1. Preliminary POST diagnostics are run. 2. Operating system is initialized. 3. Hardware is initialized. 4. Diagnostic tests are run on several functions, including circuitry, port functionality, memory, statistics counters, and serialization.
Boot
In addition to POST, boot includes the following steps after POST is complete: 1. Universal port configuration is performed. 2. Links are initialized. 3. Fabric is analyzed, and if any ports are connected to other switches, the switch participates in a fabric configuration. 4. Switch obtains a domain ID and assigns port addresses. 5. Unicast routing tables are constructed. 6. Normal port operation is enabled.
25
Installing SFPs
The switch only supports Brocade-branded SFPs. If you use an unqualified SFP, the switchShow command output will show the port in an Mod_Inv state. Fabric OS will also log the issue in the system error log. Follow these instructions to install an SFP: 1. Making sure that the bail (wire handle) B is in the unlocked position, place the SFP in the correctly oriented position on the port, as shown in Figure 9 on page 27 Note: Each SFP has a 10-pad gold-plated PCB-edge connector on the bottom. The correct position to insert an SFP into the upper row of ports is with the gold edge down. The correct position to insert an SFP into the lower row of ports is with the gold edge up. 2. Slide the SFP into the port until you feel it click into place; then close the bail.
26
A D
Figure 9. SFP installation and bail closing Item A B C C Description Switch chassis SFP with open bale SFP Closed bale
B24_0004
27
B A
C 3
1
scale: 1/8" = 1"
IO IO I
2
Figure 10. Removing an SFP Item A B
28
B24_0005
Item C D E
6. Checks whether the transmit, receive, or class 3 receiver counters are stuck at some value. 7. Checks whether the number of frames transmitted is not equal to the number of frames received. 8. Repeats Steps 2 through 7 for all ports until one of the following conditions are met: a. The number of frames (or passcount) requested is reached. b. All ports are marked bad. At each pass, the frame is created from a different data type. If seven passes are requested, seven different data types are used in the test. If eight passes are requested, the first seven frames use unique data types, and the eighth is the same as the first. The seven data types are: CSPAT: 0x7e, 0x7e, 0x7e, 0x7e, ... BYTE_LFSR: 0x69, 0x01, 0x02, 0x05, ... CHALF_SQ: 0x4a, 0x4a, 0x4a, 0x4a, ... QUAD_NOT: 0x00, 0xff, 0x00, 0xff, ... CQTR_SQ: 0x78, 0x78, 0x78, 0x78, ... CRPAT: 0xbc, 0xbc, 0x23, 0x47, ... RANDOM: 0x25, 0x7f, 0x6e, 0x9a, .... 9. If the test indicates that all ports are good, the problem is associated with either the cable or SFP. 10. Replace the SFP with an SFP known to be good.
Chapter 3. Operating the switch
29
11. Simulate the data transmission scenario when the error occurred. If the error does not reappear, the original SFP was defective, and should be discarded. If the error does reappear, the cable is defective. Replace the cable and discard the original cable. 12. Simulate the data transmission scenario again to verify that the problem does not reappear.
Diagnostic tests
In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the hardware and the firmware. This includes tests of internal connections and circuitry, fixed media, and the SFPs and cables in use. The tests are implemented by command, either through a Telnet session or through a terminal set up for a serial connection to the switch. Some tests require the ports to be connected by external cables, to allow diagnostics to verify the serializer/deserializer interface, SFP, and cable. All diagnostic tests are run at link speeds of 1, 2, 4, and 8 Gbps, depending on the speed of the link being tested. Attention: Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing. For information about specific diagnostic tests, refer to the Fabric OS Administrators Guide.
Ethernet or serial connection Ethernet or serial connection Ethernet or serial connection Ethernet or serial connection
IP over Fibre Channel IP over Fibre Channel IP over Fibre Channel Native in-band interface (over HBA only)
30
Table 8. Management options for the switch (continued) Management tool EFCM (optional purchase) For information, refer to the EFC Manager Software User Manual. Out-of-band support Ethernet or serial connection In-band support IP over Fibre Channel
Note: To achieve in-band support for IP over Fibre Channel, the software must be run on both the HBA and the switch, and it must be supported by both the HBA and HBA driver.
31
32
Environmental requirements
Table 10 lists the acceptable environment for both operating and nonoperating conditions.
Table 10. Environmental requirements Condition Temperature Humidity Altitude Shock Vibration Air flow Acceptable range during operation -10 to + 40C (14 to 104F) Acceptable range during non-operation -25 to 70C (-13 to 158F)
10% to 85% RH noncondensing, at 40C, 10% to 90% RH noncondensing, with maximum gradient of 10% per hour at 70 C 0 to 3 km (9,842 ft) above sea level 20 G, 6 ms duration, half sine wave 0.5 G, 5500 Hz High speed: 23 CFM Low speed: 18 CFM 0 to 12 km (39,370 ft) above sea level 33 G, 11 ms duration, half sine 2.0 G, 5500 Hz None required
Note: The -10 to 40 Celsius range applies to the ambient air temperature at the air intake vents on the nonport side of the switch. The temperature inside the switch can be up to 80 Celsius during switch operation. If the internal
Copyright IBM Corp. 2008, 2010
33
temperature range exceeds the operating ranges of the components, the LEDs, error messages, and Fabric Watch alerts indicate a problem. Enter the tempShow or Fabric Watch commands to view temperature status.
Facility requirements
To ensure correct operation of the switch, the facility where the switch is in use must meet the requirements listed in Table 11.
Table 11. Facility requirements Type Electrical Requirements v Primary AC input 100-240 VAC, 2.0A, 47-63 Hz; switch autosenses input voltage v Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate v Correctly wired primary outlet, with circuit protected by a circuit breaker and grounded in accordance with local electrical codes Thermal v A minimum air flow of 24 cubic ft/min available to the air intake vents on the nonport side of the switch. v Ambient air temperature not exceeding 40 C (104 F) while the switch is operating v At a minimum, adequate cooling requires that you install the switch with the nonport side, which contains the air intake vents, facing the cool-air aisle v All equipment in the rack should force air in the same direction to avoid intaking exhaust air v Ensure that airflow and temperature requirements are met on an ongoing basis, particularly if the switch is installed in a closed or multicabinet assembly Cabinet (when rack-mounted) v One rack unit in a standard EIA 19-in. (48.3 cm) cabinet v All equipment in cabinet grounded through a reliable branch circuit connection and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip v Additional weight of switch not to exceed the cabinets weight limits v Cabinet secured to ensure stability in case of unexpected movement, such as an earthquake
34
System specifications
Table 12 lists the system specifications for the switch.
Table 12. General specifications Specification Autoconfiguring port types System architecture System processor SDRAM Compact flash ANSI Fibre Channel protocol Modes of operation Fabric initialization Ethernet port Terminal port ASIC Port Status LEDs System Power LED System Status LED Ethernet LEDs Power supply Fans FC-IP (IP over Fibre Channel) Aggregate switch I/O bandwidt Port-to-port latency Descriptions F_Port, FL_Port, M_Port, N_Port, and E_Port Nonblocking shared-memory switch IBM PowerPC 440EPx, 667 MHz 512 MB DDR2 SDRAM onboard memory operating at 133 MHz 1 GB FC-PH (Fibre Channel Physical and Signalling Interface standard) Fibre Channel Class 2, Class 3, Class F Complies with FC-SW-2 6.6 One 10/100BaseT Ethernet port; accessed through RJ45 connector One UART interface for terminal, accessed through RJ-45 connector Goldeneye-2 ASIC for Fibre Channel Switching 24 LEDs (green/amber) to indicate status for each port One LED (green) to indicate system power One LED (green/amber) to indicate system status Two Ethernet LEDs to indicate speed and link status One fixed power supply (not a FRU) Three fixed fans operating at dual speeds (not a FRU). Complies with FC-IP 2.3 of FCA profile 384 Gbps if all 24 ports running at 8 Gbps, full duplex Less than 700 nanoseconds with no contention (destination port is free)
Memory specifications
The switch memory specifications are shown in Table 13.
Table 13. Memory specifications Memory type Main memory (SDRAM) Compact flash Installed memory 512 MB 1 GB
35
36
Table 15. Switch power supply specifications (continued) Specification System power consumption Input voltage Input line frequency BTU rating Inrush current Value 48 watts nominal, 57 watts maximum 85 - 264 VAC, universal 47 - 63 Hz 277 BTU/hr 21.5 Amps at 240 VAC cold start
37
38
Notices
This information was developed for products and services offered in the USA. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe on any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, N.Y. 10504-1785 U.S.A. For additional information, visit the web at: http://www.ibm.com/ibm/licensing/contact/ The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM web sites are provided for convenience only and do not in any manner serve as an endorsement of those web sites. The materials at those web sites are not part of the materials for this IBM product and use of those web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level
Copyright IBM Corp. 2008, 2010
39
systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. If you are viewing this information in softcopy, the photographs and color illustrations may not appear.
40
Trademarks
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft and Windows are trademarks of Microsoft Corporation in the United States, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Other product and service names might be trademarks of IBM or other companies.
Notices
41
42
IBM-Allee 1, 71137 Ehningen, Germany Tel: +49 7032 15-2937 E-mail: tjahn@de.ibm.com
Notices
43
Generelle Informationen: Das Gert erfllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
People's Republic of China Class A Electronic Emission Statement Japan VCCI Council Class A Statement
Translation: This is a Class A product based on the standard of the VCCI Council. If this equipment is used in a domestic environment, radio interference may occur, in which case, the user may be required to take corrective actions.
44
Russia Electromagnetic Interference (EMI) Class A Statement Australia and New Zealand Class A Statement
Attention: This is a Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures.
Notices
45
46
Index A
About this document xiii accessibility IBM commitment iv keyboard navigation iv vendor software iv address IBM v air flow requirements 33 altitude requirements 33 attention notice definition xix example xix attention notices xix
D
danger notices xv definitions xv examples xv date setting 18 default password 17 diagnostic tests 30 director of licensing, address disposal xxii documentation xiii documents Brocade xiii
features (continued) USB port 1 fiber cable testing 29 Fibre Channel port specifications 36 field replaceable unit (FRU) FRUs 26
26
39
G
general specifications getting help iii 35
H
help iii humidity requirements 33
B
boot specifications 25 Boot steps 25 Brocade documents xiii Brocade documents xiii
E
edition notice ii EFCM management 30 electrical considerations 8 requirements 8, 34 electrical requirements 8 electronic emission notices 42 environmental considerations 8 notices xxii product recycling and disposal requirements 8, 33 environmental notices xiv environmental requirements 33 Ethernet port LED patterns 25 Ethernet status LED 21 EZSwitch setup installation 16
I
IBM accessibility commitment iv address v interoperability matrix 37 notices 39 trademarks 41 in-band support 30 installation EZSwitch setup 16 slide-rail instructions 10 switch instructions 10 installing electrical requirements 8 facility requirements 34 SFP 26 slide-rail rack 8, 9 stand-alone switch 9 stand-alone unit 8, 9 switch 7 installing the switch 8 instructions installation 10 intellectual property 39 interpreting LED activity 21 Interpreting POST results 26 Interswitch Link (ISL) 3 IP address setting 17 static 17 using DHCP 17 ISL trunking groups 3 items included 7
C
cabinet considerations 8 installation 9 requirements 8, 34 cable management recommendations 15 caution notices xvii definition xvii examples xviii CLI management 30 command line interface (CLI) management 30 comments, sending to IBM iv configurations fabric 3 supported 3 configuring switch 7, 16 connectivity supported 2 considerations cabinet 8 electrical 8 environmental 8 rack 8 creating a serial connection 17
xxii
F
fabric configurations 3 Fabric Manager management 30 facility requirements 34 features 1U chassis 1 auto-sensing Fibre Channel ports 1 built-in fans 1 built-in power supply 1 Dynamic Path Selection (DPS) 1 Ethernet port 1 EZSwitchSetup wizard 1 Inter-Switch-Link trunking 1 LEDs 1 NPIV access gateway 1 optional 4 RJ45 Ethernet management port 1
47
K
keyboard navigation iv
L
labels, safety xix LED activity 21 descriptions 2 Ethernet status 21 interpretation 21 locations 2, 22 patterns 23 system power 21 system status 21 types 21 LED patterns Ethernet port 25 port status 23 power status 23 system status 23 license agreement iv license, for patents 39 local time synchronizing 19 using NTP 19
notices (continued) types xv notices ,danger xv notices and labels safety xiv NTP time synchronization 19
P
parts supplied with switch rack-mount kit 11 password default 17 patents 39 physical dimensions 33 port activation 3 descriptions 2 Ethernet 2 Fibre Channel 2 locations 2 system console 2 testing 29 USB 2 port side LEDs 22 switch 2 port status LED 21 LED patterns 23 POST interpreting results 26 specifications 25 POST and boot specifications 25 POST steps 25 power consumption 36 switch 16 power status LED patterns 23 power supply BTU rating 36 inlet connector 36 input line frequency 36 input voltage 36 inrush current 36 maximum output 36 specifications 36 product documentation xiii product specifications 33 data transmission ranges 36 environmental requirements 33 Fibre Channel ports 36
rack (continued) safety xx rack mount kit 11 rack relocation safety xxi rack safety xx read this first iii recycling xxii removing SFP 28 requirements air flow 33 altitude 33 cabinet 34 cacbinet 8 electrical 8, 34 environmental 8, 33 humidity 33 rack 8 shock 33 temperature 33 thermal 34 vibration 33 results POST 26
S
safety xiv considerations 8 labels xiv, xix examples xix notices xiv rack xx rack installation xx rack relocation xxi safety labels xix safety notices xiv serial connection creating 17 UNIX 17 Windows 17 serial port specifications 36 setting date 18 IP address 17 time 18 time zones 18 setting the IP address 17 SFP bail 26, 28 FRUs 26 installing 26 removing 28 supported 37 supported types 26 testing 29 shock requirements 33 SNMP management 30 specifications boot 25 data transmission ranges Fibre Channel ports 36 general 35
M
maintaining switch 26 maintenance switch 26 management CLI 30 EFCM 30 Fabric Manager 30 in-band 30 Management Server 30 SNMP 30 Web Tools 30 management features 30 Management Server management 30 managing cables 15 memory 35
N
network time protocol (NTP) time synchronization 19 nonport side switch 3 notice, edition ii notices attention xix caution xvii danger xv environmental xiv, xxii general 39 IBM 39 patents 39 safety xiv
Q
qualified SFPs 26
R
rack considerations 8 requirements 8
36
48
specifications (continued) memory 35 physical dimensions 33 POST 25 power supply 36 product 33 serial port 36 system 35 weight 33 stand-alone switch 9 installing 9 static IP address setting 17 supported SFPs 26 supported (optional) features 4 supported connectivity 2 switch airflow 3 cabinet 9 configuring 7, 16 features 1 See features FRU units 26 installing 7, 9 introduction 1 items included 7 library xiii maintaining 26 maintenance 26 management features 30 memory 35 nonport side 3 parts supplied with the rack-mount kit 11 physical dimensions 33 port side 2 power 16 powering on and off 21 product specifications See product specifications specifications 35 stand-alone 9 weight 33 synchronizing local time 19 system power LED 21 system specifications 35 system status LED 21 LED patterns 23
V
vendor software iv vibration requirements 33
W
Web sites iii Web Tools management weight 33 30
T
temperature requirements 33 terminal emulator applications testing fiber cable 29 port 29 SFP 29 tests diagnostic 30 thermal requirements 34 17
Index
49
50
Printed in USA
GA32-0580-02