s Overview
The DN6851 is an integrated circuit making use of Hall effects. It is designed particularly for operating at a low supply voltage in alternative magnetic field. It is suitable for various sensors and contactless switches.
2.00.3 4.50.3 4.00.3 1.0 0.7 Unit : mm

s Features
Wide range of supply ; 3.6 to 16V Operating in alternative magnetic field. TTL and MOS ICs directly drivable by output Semipermanent service life because of no contact parts Drivable with a small magnet 3-pin SIL plastic package (3-SIP)
10.50.5 0.80.1

0.50.1 1.27 5 1 2 3 5

0.43 0.05

+ 0.1

s Applications
Speed sensors Position sensors Rotation sensors Keyboard switches Microswitches
Note) This IC is not suitable for car electrical equipments.

2 SSIP003-P-0000A (E-3S)

1 : VCC 2 : GND 3 : Output

s Block Diagram
Stabilized power supply 1

VCC

27k 3

Output

2 Hall element Amp. Schmitt trigger Output stage

GND

s Absolute Maximum Ratings (Ta=25C)


Parameter Supply voltage Supply current Circuit current Power dissipation Operating ambient temperature Storage temperature Symbol VCC ICC IO PD Topr Tstg Rating 18 8 20 100 40 to +85 55 to +125 Unit V mA mA mW C C

s Electrical Characteristics (Ta=25C)


Parameter Operating flux density Symbol B1 (L to H) B2 (H to L) Low output voltage VOL VCC=12V VCC=12V VCC=16V, IO=12mA, B=30mT VCC=3.6V, IO=12mA, B=30mT VCC=16V, IO=30A, B=30mT VCC=3.6V, IO=30A, B=30mT VCC=16V, VO=0V, B=30mT VCC=16V VCC=3.6V Condition min 30 30 0.4 0.4 14.6 2.2 0.4 0.9 6 5.5 typ max Unit mT mT V V V V mA mA mA

High output voltage

VOH

Output short-circuit current Supply current

IOS ICC

Note 1) Operating supply voltage range VCC (opr)= 3.6 to 16V Note 2) For the operating flux density, 20 gauss is also available as Rank A.

s Hall Element Position


1.75 1.3

1.0

Unit : mm The center of the Hall element is in the hatched area in the left figure.

s Flux-Voltage Conversion Characteristics


S Marking surface Output voltage (VO)

1.0 3

N Applied flux direction

1 : VCC 2 : GND 3 : Output

B1

B2

Flux density (B)

s Precaution on Use
1. Change of the operation magnetic flux density dose not depend on the supply voltage, because the stabilization power supply is built-in. (only for the range; VCC = 4.5 to 16V) 2. Change from H to L level increases the supply current by approx. 1mA.