05-APR-11
HORIZONTAL MOTORS
ODP CLOSE-COUPLED PUMP FRAME: 182, 184JM, JP BASIC TYPE: D4, D1
PRINT:
07-2011 1 OF 1
SUPERSEDES:
04-AUG-03
C AG BS AH BB
SHEET:
P AB AC
45
AJ T AK BD AF D AA SIZE CONDUIT J E 2E A G O BF 4 HOLES
EV K 2F B EL EM BA ER
H4 HOLES
ES EP U EQ ET AH
ALL DIMENSIONS ARE IN INCHES AND MILLIMETERS D 2E H E J K G -.06 .03 +.05
4.50 114 3.75 95 7.50 191 .19 5 .41 10 1.13 29 2.00 51
EN
UNITS
IN MM
A
8.75 222
B
6.50 165
O
8.50 216
P
8.00 203
T
.94 24
UNITS
IN MM
U -.0005
.8745 22.212
AA
.75
AB
6.88 175
AC
5.63 143
AF
2.13 54
AG
13.19 335
AJ
5.875 149.23
AK -.003
4.500 114.30
BA
3.63 92
BB -.031
.156 3.96
BD MAX
6.63 168
UNITS
IN MM
BF
BS F-1
6.00 152
BS F-2
1.00 25
EL -.002
1.250 31.75
EM -.0005
1.0000 25.400
EN
EP MIN
1.25 32
ES MIN
1.66 42
EV
.50 13
SQ KEY
.188 4.78
3/8-16 X .56
3/8-16 X .75
FRAME
182JM,JP 184JM,JP
UNITS
IN MM IN MM
2F .03
4.50 114 5.50 140
FRAME
180JM 180JP
UNITS
IN MM IN MM
C
17.44 443 20.50 521
AH .031
4.250 107.95 7.313 185.75
EQ .015
.625 15.88 1.563 39.70
ER MIN
4.25 108 7.31 186
ET .015
2.875 73.03 5.938 150.83
1. ALL ROUGH DIMENSIONS MAY VARY BY .25" DUE TO CASTING AND/OR FABRICATION VARIATIONS. 2. LARGEST MOTOR WIDTH. 3: STANDARD ASSEMBLY POSITION F-1 SHOWN. F-2 IS PROVIDED WHEN SPECIFIED.CONDUIT OPENINGS MAY BE LOCATED IN STEPS OF 90 DEGREES REGARDLESS OF LOCATION. STANDARD AS SHOWN WITH CONDUIT OPENING DOWN. 4: TAP SIZE AND BOLT PENETRATION ALLOWANCE. 5: ALL TAPPED HOLES ARE UNIFIED NATIONAL COARSE, RIGHT HAND THREAD. 6: LIFTING LUGS - WHEN SPECIFIED ON BILL. 7: TOLERANCES SHOWN ARE IN INCHES ONLY. 8: FRAME REFERENCE: 7.750/182/184 07-2011/B
TOLERANCES FACE RUNOUT PERMISSIBLE ECCENTRICITY OF MOUNTING RABBET PERMISSIBLE SHAFT RUNOUT
ISSUED BY
INFORMATION DISCLOSED ON THIS DOCUMENT IS CONSIDERED PROPRIETARY AND SHALL NOT BE REPRODUCED OR DISCLOSED WITHOUT WRITTEN CONSENT OF NIDEC MOTOR CORPORATION
L. CUESTA
APPROVED BY
M OT O R S
F. LARA