REPORT OF LABORATORY TESTING

No: 0259
Date Client Anode's Type Alloy's Type Testing Method Standard : March 26th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

Closed Circuit Potential of Anodes Sample No at the end of testing periode Sample Code 1st Vs Ag/AgCl Reference Cell ( - millivolt) 2nd 3rd

Electrochemical Efficiency of Anode (Amp. hr / kg) avg Efficiency of Anodes ( %)

11 12 13 14 15

K L M N O

1,398 1,415 1,724 1,717 1,425

1,397 1,417 1,726 1,715 1,425

1,395 1,412 1,727 1,714 1,427

1,396.67 1,414.67 1,725.67 1,715.33 1,425.67

2,013.69 2,091.54 2,630.57 2,926.57 1,939.68

67.57 70.19 88.27 98.21 65.09

REPORT OF LABORATORY TESTING


No:
Date Client Anode's Type Alloy's Type Testing Method Standard : March 26th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

ANODES COMPOSITION Sample No 11 12 13 14 15 Code of Sample K L M N O

REPORT OF LABORATORY TESTING


No: 0259
Date Client Anode's Type Alloy's Type Testing Method Standard : March 26th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

RESULTS OF DAIILY CIRCUIT POTENTIAL (OPEN & CLOSED)


Sample No 11 12 13 14 15 Code of Sample K L M N O Date: 1st 1398 1416 1679 1568 1399 OCP (-mV to Ag/AgCl) 24 March 2009 (0 Hours) 2nd 1395 1417 1677 1569 1397 3rd 1397 1418 1680 1564 1398 avg 1,396.67 1,417.00 1,678.67 1,567.00 1,398.00 Date: 1st 1,257 1,371 1,551 1,352 1,246 CCP (-mV to Ag/AgCl) 24 March 2009 (0 Hours) 2nd 1,256 1,370 1,553 1,354 1,247 3rd 1,254 1,373 1,556 1,355 1,247 avg 1,255.67 1,371.33 1,553.33 1,353.67 1,246.67 Date: 1st 1,324 1,355 1,619 1,497 1,347 CCP (-mV to Ag/AgCl) 25 March 2009 (24 Hours) 2nd 1,321 1,360 1,610 1,501 1,347 3rd 1,326 1,358 1,615 1,499 1,345 avg 1,323.67 1,357.67 1,614.67 1,499.00 1,346.33

Sample No 11 12 13 14 15

Code of Sample K L M N O

Date: 1st 1,340 1,386 1,661 1,606 1,394

CCP (-mV to Ag/AgCl) 26 March 2009 (48 Hours) 2nd 1,341 1,385 1,660 1,600 1,393 3rd 1,339 1,389 1,558 1,604 1,395 avg 1,340.00 1,386.67 1,626.33 1,603.33 1,394.00

OCP (-mV to Ag/AgCl) Date:


1st 1,398 1,415 1,724 1,717 1,425 26 March 2009 (48 Hours) 2nd 1,397 1,417 1,726 1,715 1,425 3rd 1,395 1,412 1,727 1,714 1,427 avg 1,396.67 1,414.67 1,725.67 1,715.33 1,425.67

REPORT OF LABORATORY TESTING


No: 0259
Date Client Anode's Type Alloy's Type Testing Method Standard : March 26th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

Sample No 11 12 13 14 15

Code of Sample K L M N O

ANODES SAMPLES WEIGHING Weight Before Testing (gram) Weight After Testing (gram) 1st 11.2975 12.1971 9.8075 10.4997 11.6661 2nd 11.2975 12.1971 9.8075 10.5 11.6657 3rd 11.2976 12.197 9.8074 10.4997 11.6661 avg 11.2975 12.1971 9.8075 10.4998 11.6660 1st 11.1184 12.0247 9.6703 10.3765 11.4867 2nd 11.1185 12.0246 9.6704 10.3766 11.4866 3rd 11.1184 12.0246 9.6704 10.3766 11.4668 avg 11.1184 12.0246 9.6704 10.3766 11.4800

Weight Loss (gram) 0.1791 0.1724 0.1371 0.1232 0.1859

REPORT OF LABORATORY TESTING


No: 0259
Date Client Anode's Type Alloy's Type Testing Method Standard : March 26th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

Weight (gram) Cu Rod 6.7907 6.7908 6.7909 6.7908 7.2186 7.2185 7.2183 7.2185 0.4277 Cu Plate 1 24.2878 24.2883 24.2884 24.288 24.0763 24.0757 24.0754 24.0758 0.2130 Cu Plate 2 24.5103 24.5107 24.5106 24.511 24.2753 24.2755 24.2752 24.2753 0.2354 Sample

Weight Before Testing (gram) 1st 2nd 3rd avg

COPPER COULOMETER Weight After Testing (gram) 1st 2nd 3rd avg

Total Current Charge (ampere hours) 0.3607

Total Current Charge (ampere hours) = 0,8433 * Weight Cu rod (grams)

REPORT OF LABORATORY TESTING


No:
Date Client Anode's Type Alloy's Type Testing Method Standard : March 14th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

PHOTOS AFTER TESTING

Cu Coulometer

Before Cleaning Sample K

After Cleaning

Sample L

Page 6 of 9

REPORT OF LABORATORY TESTING


No:
Date Client Anode's Type Alloy's Type Testing Method Standard : March 14th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

PHOTOS AFTER TESTING

Sample M

Sample N

Sample O

Page 7 of 9

REPORT OF LABORATORY TESTING


No:
Date Client Anode's Type Alloy's Type Testing Method Standard : March 14th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

PHOTOS AFTER TESTING

Page 8 of 9

REPORT OF LABORATORY TESTING


No: 0259
Date Client Anode's Type Alloy's Type Testing Method Standard : March 26th 2009 : PT. KAR : Aluminum : : LABORATORY TESTING OF GALVANIC MATERIALS FOR QUALITY CONTROL : RECOMMENDED PRACTICE DNV-RP-B401(2005)

SUMMARY Based on our laboratoratory testing of galvanic materials for quality control based on recommended practice DNV-RP-B401 (2005), only sample13 & 14 complies with the standard which the value of electrochemical capacity is exceeded the minimum requirement of 2500 Ah/kg and the closed circuit potential is below -1.05V at the end of modified testing period (2 days). This testing is conducted principally by measuring weight loss of aluminium anodes to obtain electrochemical efficiency and measuring the close potential of anodes. These two parameters are obtained by current setting in daily basis.

Calculation Procedure and Examples


Electrochemical Efficiency of Anodes e = Electrochemical Efficiency (Ampere.hours/kg) C = Total current charge from Coulometer (Ampere.hours) Dw = average aluminium weight loss (grams)

e
Example Dw = C= e=

C * 1000 Dw

0.1371 grams 0.3607 Ampere.hours 2630.57 (Ampere.hours/kg)

Efficiency of Anodes Anode efficiency (%) = Electrochemical Efficiency of Tested Anode (Ampere.hours/kg) 2980 Ampere.hours/kg (Electrochemical Efficiency of Pure Anode) 2630.57 Ampere.hours/kg 88.27 % *100%

Example Electrochemical Efficiency of Tested Anode = Anode Efficiency =

Reference
1. Recommended Practice DNV - RP - B401,"Cathodic Protection Design", Norwey: Det Norske Veritas, 2005 2. NACE Standard TM0190-98 Item No.21221, "Standard Test Methode Impressed Current Laboratory Testing of Aluminum Alloy Anodes", Houston: NACE international, 1998 3. A. Jones, Denny, Principles and Prevention of Corrosion, New York: Macmillan Publishing Company, 1992