Dear Sir, Please note the following changes in centrifugal pumps data sheets.

Please make necessary changes and revert back to us.

P-3309 = Quantity has to be increased from one to two. 1 working and 1 standby (A/S). Material of Construction (MOC) is to be changed from SS316 to SS304.

P-3134 = Normal flowrate has to be changed from 10 m3/hr to 5 m3/hr. P-3611 = Quantity has to be increased from one to two. 1 working and 1 standby (A/S). P-3506 A/S = Material of Construction (MOC) is to be changed from SS304 to SS316. P-3404 = Quantity has decreased from two to one. 1 working and NO standby. P-3405 = Quantity has to be increased from one to two. 1 working and 1 standby (A/S). P-3161 A/B/C/D/E , P-3162 = Normal flowrate has to be changed from 10 m3/hr to 25 m3/hr. P-3231 = Quantity has to be increased from one to two. 1 working and 1 standby (A/S). P-3319 = Pump is deleted (It is a metering pump). P-3325 A/S = This pump is to be of jacketed type. Hot oil at 250'C will be circulated through the jacket. P-3326 A/S = NPSHA is to be changed from >10 m to 4.9 m

Suction Pressure is to be changed from 13.13 m to 4.92 m Differential head is to changed from 20 m to 25 m Discharge pressure is to changed from 33.13 m to 24.02 m

P-3354 A/S =

NPSHA is to be changed from >10 m to 4.81 m

Suction Pressure is to be changed from 13.3 m to 4.84 m Differential head is to changed from 10 m to 20 m Discharge pressure is to changed from 23.3m to 21.18 m