CONNECTIONS.txt CONNECTIONS @ C1 WIND RATING ***************************************** *FLOOR MEMBERS * ***************************************** UPLIFT --TIMBER BEARER/TIMBER COLUMN-AREA SUPPORTED: 3.

5M FORCE OF UPLIFT: 4.2KN SELECTED CONNECTION: 2-M10 BOLTS THRU TIMBER POST --TIMBER BEARER/STEEL COLUMN-AREA SUPPORTED: 9.2M FORCE OF UPLIFT: 11.0KN SELECTED CONNECTION: 75 x 10PL (4CFW TO POST) WITH 2-M10 BOLTS THRU BEARER --TIMBER JOISTS-AREA SUPPORTED: 1.575M FORCE OF UPLIFT: 1.9KN SELECTED CONNECTION: TYPE 1: 1-30x0.8MM GI STRAP WITH 3-2.8MM NAILS EACH END. TYPE 2: JOIST HANGER TO MANUFSPEC. ***************************************** SHEAR (SHEAR CONNECTIONS OVERRULE UPLIFT CONNECTIONS IF STRONGER) --ALL JOISTS-NOMINAL CONNECTIONS AS PER AS1684.3 --BEARER @ TIMBER COLUMNS-SPAN/SPACING: 2.0M HEIGHT TO ROOF: 3.1M PRESSURE: 1.4KPA FORCE PER CONNECTION: 8.68KN SELECTED CONNECTION: 2-M12 BOLTS THRU TIMBER POST --BEARER @ STEEL COLUMNS-SPAN/SPACING: 2.575M HEIGHT TO ROOF: 5.0M PRESSURE: 1.4KPA FORCE PER CONNECTION: 18.025KN SELECTED CONNECTION: MS ANGLE CFW TO POST; 2-M12 BOLTS THRU BEARER ***************************************** *ROOF MEMBERS * ***************************************** UPLIFT --TIMBER VERANDAH PLATE/TIMBER COLUMNS-AREA SUPPORTED: 3.4M FORCE OF UPLIFT: 7.1KN SELECTED CONNECTION: 2-M10 BOLTS THRU TIMBER POST --TIMBER RAFTER/TIMBER VERANDAH PLATE-AREA SUPPORTED: 1.53M FORCE OF UPLIFT: 4.2KN SELECTED CONNECTION: 1-30x0.8MM GI STRAP WITH 4-2.8MM NAILS EACH END