Check list for B&M plant

Compressor turned on

Mixers -empty -closed -in Elimix mode

Scales -empty -readings ok.

Shuttles -ready in stations -empty -power turned on for used tracks -Reset from ELIMIX to station (under limit switch) -turned up position Material checking

Water pumps on

Aggregate filling: Service/auto switch auto position( upper and lower level) Choose silo to fill(1-8) When light is on for selected silo ,upper distribution belt is turned correct position. Select filling silo 1 or 2 . Start filling pushing start belt button. Stop filling pushing stop button Belts and vibrators stops one by one.

Reasons for unexpected stopping of automated operation: Side limits: Lower belt, upper distribution belt. Rotation control: Lower belt, distribution belt and elevator Material guard in elevator (lower part) Protection switches for all belts, vibrator feeder, vibrators and elevator. Emergency wire of lower belt. Material upper level limit switches.

Cement filling: Check control voltage. Check air is ok. Open cement filling pipes closing grip. Connect cement trucks tanks pipe to filling pipe. Select silo to fill 1 or 2. Push start button.

ELIDIST Order places for Elimix 3104 Hall 1/Track C, Station4, Gantry, 4104 Hall 2/Track D, Station 4, Casting machine, 5104 Hall 3/Track E, Station 4, Discharge Place, 6104 Hall 4/Track F, Station 4, Discharge Place, 6105 Hall 4/Track F, Station 5,Casting machine

A6/B6 are waiting places for shuttles during automated use of track.

Track B, Station 7, is place for waste material. Shuttle must drive to that station in manual mode(Elimix).

Always leave shuttles under limit switches. Shuttles image is shown in Elidist window.

Reset all shuttles before use from Elidist window(Reset button).--> Shuttle image and red point in same position.