GL-Reg. 114270, Hull No. 226 / 35 Note : Items will be listed and updated as per survey progress. SL date system Drawing No 1H 2H 3H 4H 5S 6S 7H 8H 9H 2012-02-26 2012-02-26 2012-02-26 2012-02-26 Hull Hull Hull Hull Frame Modification for GB Locking Transverse coaming 1048/07-1201 Rev.C 1048/07-1073 rev. B 1048/07-1034 Rev. A open item

Hull & Statutory

Status Open Open Open Open Open Open Open Open Open Open Open

remarks

A Bracket missing at Frame 51 in way of GB locking device Red entry at Frame 138 "Side Shell structure and forecastle deck construction in this area is not cleared, please submit" All the holes in the cylinder foundation to be closed. At Frame 153, lower end bracket of anchor pocket is missing Permanently attached closing appliances to be provided for spurling pipes to reduce water ingress. Details of Inspection opening of Chain locker to be submitted to GLHO for approval. Bracket missing at two ends. Centre Lightening hole area to be reduced by insert plate Mooring substructure for poop deck - Star board side not ready for inspection. (already covered by insulation) Air pipes and Ventilation pipes on Freeboard deck to strengthened by brackets. Freeing port details including maindeck forward (between cargo hold and forecastel BHD) to be submitted to GLHO for examination. Also seen that no freeing port is provided.

2012-02-26 Loadline 1048/07-2280 Rev. D 2012-02-26 Loadline 1048/07-2280 Rev. D 2012-02-26 2012-02-27 2012-02-27 Hull Hull Hull 1048/07-1033 Rev. B 1048-07/1250 REV.0 H2-1331

10S 2012-02-27 Loadline 11S 2012-02-28 Loadline

Ataur Rahman GL Chittagong 2012-02-28