HMI

Thiet b HMI (Human machine interface) dung e giao tiep gi PLC va ngi van hanh, hien th cac thong tin ch so tren man hnh LCD, co cac phm e ngi dung tac ong en PLC. Co cac loai HMI nh TD (TextDisplay) TP (Touch Panel), OP (Operator Panel)
Devices having a Text-Based Display TD17, TD200 OP3 OP5, OP15 OP7, OP17 TD10, TD20, OP20 (with COM TEXT only) Devices having a Graphics Display OP25, OP35

OP27, OP37 TP27, TP37

1/ TD200 TD200 la thiet b hien th van ban giao tiep vi PLC S7-200, co trang b cac phm bam e tac ong en PLC

Component Text Display Area

Description Man hnh LCD hai hang, chieu sang sau (backlit), 20ky t cao 5mm/hang Gasket Mieng ron em chong anh hng moi trng Communication Port Cong 9 chan ghep vi PLC, chuan PPI, RS485, 9.6 Kb/s Power Connection Nguon ngoai 24VDC/100mA, khong can neu dung cap TD/CPU User Label Nhan dung e at ten cho cac phm Keys Co 9 phm gom 5 phm chc nang va 4 phm danh cho ngi dung Spacers Mieng em dung e gan TD200 Command Keys Description ENTER Ghi d lieu mi va chap nhan message. ESC Chuyen gia Display Message mode va Menu mode hay e huy bo edit UP ARROW Tang d lieu va trt con chay en message u tien cao hn DOWN ARROW Giam d lieu va trt con chay en message u tien thap hn SHIFT Dung vi cac phm F1..F4 Function Keys F1 Description Cho bit Mx.0 len 1. Neu kem vi SHIFT th cho bit Mx.4 len 1

F2 F3 F4

Cho bit Mx.1 len 1. Neu kem vi SHIFT th cho bit Mx.5 len 1 Cho bit Mx.2 len 1. Neu kem vi SHIFT th cho bit Mx.6 len 1 Cho bit Mx.3 len 1. Neu kem vi SHIFT th cho bit Mx.7 len 1

TD200 co the ket noi vi mot PLC hay noi trong mang MPI nhieu PLC, nhieu TD200, moi TD200 co mot a ch (mac nh 1) va ket noi vi mot PLC co a ch a nh san (mac nh 2). Mot PLC co the giao tiep vi nhieu TD200

1.2/ AT CAU HNH CHO TD200 Thong so hoat ong cua TD 200 cha trong khoi thong so cau hnh thuoc vung nh V cua PLC. Khoi thong so nay c cai at tren PLC nh phan mem STEP7-MICROWIN- TD 200 Configuration Wizard. Tren TD200 cha cac thong so nh a ch cua no va PLC lien ket, van toc truyen, a ch khoi thong so. 1.2.1 S dung TD200 Configuration Wizard Chay phan mem Step7- Micro/Win 32, vao menu Tool- TD 200 Wizard- Next. Neu a co san khoi cau hnh TD200 ta se chon tao khoi mi hay bien tap khoi cu. Mot PLC co the noi vi nhieu TD200 vi cac khoi cau hnh cac a ch khac nhau cua vung nh V

Chon ngon ng va tap ky t phu hp

- Chon cac option menu TOD e thay oi ngay gi, force menu e cng bc cac tn hieu vao/ra cua PLC, password protection e a password vao TD200 (4 so t 0000 en 9999)

Chon cac bit cua vung nh M tac ong khi bam phm F1..F4 va tan so cap nhat Chon kch thc va so message

- Khoi d lieu cau hnh cha trong vung nh V, oi hoi 12 byte e cha thong so , mot byte c cho phep vi moi message, 20 hay 40 byte cho mot message tuy theo ta chon message loai 20 hay 40 ky t. Moi message co mot bit cho phep. TD200 lien tuc oc cac bit nay va hien th message tng ng khi bit nay ON. -ien noi dung message theo th t message u tien t cao en thap, trong chng trnh PLC khi bit Message Enabled ON se ieu khien TD200 hien th message. - Trong message co the xen d lieu thap phan thay oi. Can phai danh cho trong message e cha d lieu. D lieu word can hai byte d lieu va hai byte format, d lieu word kep hay so thc can 4 byte d lieu va hai byte format. Neu la so co dau th so am hien th vi dau tr . So thc hien th toi a 6 so co ngha.. V du message 20 ky t gom ch WATERFLOW: va gia tr lu lng la mot word kep kem theo n v m3/s , ta go cac ky t can thiet sau o at con tro chuot vao v tr so 11 roi bam Embedded Data

Chon cach thc trnh bay d lieu, loai word hay word kep, so so le sau dau phay, .. bam OK - Chuyen sang message ke - Sau khi a bien soan xong bam Finish - Co the vao lai khoi cau hnh e xem lai hoac sa cha, chu y a ch cua d lieu, a ch cac bit cho phep Message enabled; bit Edit Notification se ON khi ngi dung bien tap gia tr d lieu, chng trnh PLC se quyet nh s dung d lieu mi hay khong va xoa bit nay - oi khi mot message oi hoi xac nhan t ngi van hanh, v du message OV-FLOWPRESSENTER oi hoi ngi dung bam enter khi hien message, la chon nay can hai byte, ta bam chuot vao o trong sau message (toi thieu hai o trong) sau o bam Embedded Data chon Data format la None va User must acknowledge message- OK -

- Khi xuat hien message can xac nhan , man hnh TD200 se chp, neu ngi dung bam phm Enter th man hnh ngng chp, bit Acknowledgement notification ON, bit Message enabled OFF , chng trnh ngi dung phai xoa bit Acknowledgement notification. - Muon xem khoi cau hnh dang van ban ta bam chuot vao menu View- Data Block
// //DATA BLOCK COMMENTS // //Press F1 for help and example data block // //BEGIN TD200_BLOCK 0 // //(Comments within this block should not be edited or removed) // VB0 'TD' VB2 16#10 //Set Language to English, set Update to as fast as possible VB3 16#70 //Set the display to 20 character mode; Up key V3.2; Down key V3.3; VB4 3 //Set the number of messages VB5 0 //Set the Function Keys notification bits to M0.0 - M0.7 VW6 32 //Set the starting address for messages to VW32 VW8 12 //Set the starting address for message enable bits to VW12 VW10 0 //Global Password (if enabled) //MESSAGE 1 //Message Enable Bit V12.7 VB32 'WATERFLOW:' VB42 16#18 //Edit Notification V42.2; No Acknowledgement;Edit Requires Password; VB43 16#22 //Signed Double Word; 2 Digits to the right of the decimal; VD44 16#00000000 //Embedded Data Value: Move data for display here. VB48 'M3/s' //MESSAGE 2 //Message Enable Bit V12.6 VB52 'OV-FLOW-PRESSENTER' VB70 16#01 //No Edit;Acknowledgement Notification V70.1; No Password; VB71 16#00 //No Data; 0 Digits to the right of the decimal; //MESSAGE 3 //Message Enable Bit V12.5 VB72 ' ' //END TD200_BLOCK 0

1.2.2 Van hanh TD200 1.2.2.1 Mode Display Message Khi cap ien, TD200 vao mode Display Message. Trong mode nay dung cac phm UP DOWN e duyet qua cac message dai cha hien th het. Neu trong message co d lieu can bien tap, au tien chon message dung UP DOWN, sau o bam ENTER vao mode edit (neu d lieu c bao ve can phai a password vao), bam SHIFT UP, SHIFT DOWN e di chuyen con trt en digit can thay oi, dung UP DOWN tang giam digit o, dung SHIFT ENTER xoa bien ve 0. Sau khi bien tap xong bam ENTER e a gia tr mi vao PLC, bit edit notification se ON. Neu khong bien tap gia tr hay bam ESC bit message enabled se khong c xoa. Neu message can xac nhan ngi dung th phai bam ENTER 1.2.2.2 Mode Menu Khi bam ESC (phai vao password neu co bao ve) TD200 vao mode Menu vi 6 muc, dung UP DOWN va ENTER e chon cac muc. TD200 tr ve mode Display neu bam ESC hay khong bam phm g sau 1 phut. a/ View Message: dung ENTER UP DOWN e xem cac message

b/ View Status: xem cac thong bao loi cua PLC c/ Force I/O: cng bc cac ngo vao ra cua PLC, neu PLC c bao ve th can phai a password cua PLC vao (8 ky t). d/ Set Time and Date: neu PLC co ong ho va at cau hnh TD200 la enable TD menu th muc nay se hien th thi gian cua PLC e ngi dung bien tap gia tr neu can va cai lai ngay gi mi cho PLC. e/ Release password : trong che o bien tap, neu TD200 co cai password, khi khong nhan phm trong vong 2 phut, TD200 se t ong yeu cau nhap lai password, neu muon vao che o password ngay th dung phm UP DOWN e vao muc Release password bam ENTER. f/ TD 200 Setup: at a ch TD200 (TD200 ADDRESS), PLC (CPU ADDRESS), a ch khoi d lieu cau hnh (PARM ADDRESS), van toc truyen (BAUD RATE) bang cac phm UP DOWN ENTER. 1.3 V du: Press F1 to go to the setpoint message. Press ENTER to edit the setpoint. Press ENTER again to go to the acknowledge message. Press ENTER to acknowledge the third message. Press F2 to enable all three messages at once. Press F3 to disable all the messages. Khoi cau hnh TD200
// BEGIN TD200_BLOCK 0 // (Comments within this block should not be edited or removed) VB0 TD // TD 200 Identification VB2 16#10 // Set Language to English, set Update to As fast as possible VB3 16#71 // Set the display to 40 character mode; Up key V3.2; Down key V3.3 VB4 3 // Set the number of messages VB5 0 // Set the Function Keys notification bits to M0.0 M0 VW6 40 // Set the starting address for messages to VW40 VW8 12 // Set the starting address for message enable bits to VW12 VW10 1111 // Global Password // MESSAGE 1 // Message Enable Bit V12.7 VB40 PRESS F1 TO DISPLAY THE NEXT MESSAGE ... // MESSAGE 2 // Message Enable Bit V12.6 VB80 PREV. SETPOINT: VB96 16#00 // No Edit; No Acknowledgement; No Password VB97 16#11 // Signed Word; 1 Digits to the right of the decimal; VW98 16#00 // Embedded Data Value: Move data for display here. VB100 NEW SETPOINT: VB114 16#18 // Edit Notification V114.2; No Acknowledgement; Edit Requires Passw VB115 16#51 // Real Double Word; 1 Digits to the right of the decimal; VD116 16#0000 // Embedded Data Value: Move data for display here. // MESSAGE 3 // Message Enable Bit V12.5 VB120 ACKNOWLEDGE MESSAGE BY PRESSING ENTER: VB158 16#01 // No Edit; Acknowledgement Notification V158.1; No Password VB159 16#00 // No Data; 0 Digits to the right of the decimal; // END TD200_BLOCK 0

Chng trnh PLC

NETWORK 1 LD SM0.1 // if this is the first scan MOVB 16#80, VB12 // ...enable the first message MOVB 0, MB0 // ...clear all function key bits NETWORK 2 LD M0.0 // if F1 has been pressed MOVB 16#40, VB12 // ...enable message 2 for display R M0.0, 1 // ...reset F1 key M bit NETWORK 3 LD V114.2 // if new setpoint edit bit is set R V114.2, 1 // ...reset edit bit MOVR VD116, AC0 // ...get edited real value *R 10.00000, AC0 // ...times 10 for scaling TRUNC AC0, AC1 // ... convert to an integer MOVW AC1, VW98 // ... update prev. setpoint value MOVB 16#20, VB12 // ...enable message 3 for display

NETWORK 4 LD V158.1 // if message 3 acknowledge bit is set R V158.1, 1 // ...reset message 3 ack bit MOVB 16#80, VB12 // ...enable message 1 for display NETWORK 5 LD M0.1 // if F2 has been pressed MOVB 16#E0, VB12 // ...enable all 3 messages at once R M0.1, 1 // ...reset F2 key M bit NETWORK 6 LD M0.2 // if F3 has been pressed MOVB 0, VB12 // ...disable all messages R M0.2, 1 // ...reset F3 key M bit NETWORK 7 MEND

2/ MAN HNH OP25/35/45 Cac man hnh nay trnh bay c hnh anh va ch, thong so cho bang di:
Cac model Display OP 25 Co OP 35 Co Co OP 45 Co

en trang Mau

o phan giai 320 x 240 640x 480 640x 480 Kch thc man hnh 115x 86mm 192x 144mm 211x 158mm en chieu nen (backlit) huynh quang CCFL (cold cathode fluorescent lamp ) tuoi tho 10.000 gi Ban phm Phm chc nang co 24 32 32 nh (system key) Phm chc nang thay 24 (18 co en LED) 36 (28 co en LED) 36 (28 co en LED) oi (function key) 2 x V.24/TTY 1 x V.24/TTY Truyen thong Ghep vi may in, 1 x RS 422/RS 485 1 x V.24 PLC , may tnh, HMI
1 x TTY/RS 422/RS 485 1Mbyte 1 x RS 485

Bo nh

Flash EPROM cha firmware va d lieu ngi dung DRAM cha d lieu lam viec Bo nh cau hnh

2Mbyte

2 Mbyte 1 Mbyte F8680- 14MHZ

4 Mbyte 3 Mbyte 386 -25MHZ Option

8 Mbyte 5.5 Mbyte 486-DX2- 33MHZ Co 425 MByte 115/230VAC /1.4A

Vi x ly a mem a cng Kch thc ien ap nguon

296x192x67 24VDC/0.6A

24VDC/1A

2.1 Cau tao OP 25

Phm SHIFT

Dung e chuyen oi t cac phm so 0..9 sang cac phm ch trai hay phai, en bao cho biet chc nang cua cac phm Chuyen t phm ch sang phm so Chuyen ca so tch cc Chap nhan message

M man hnh hng dan Phm Enter Con chay len, xuong, trai, phai, ket hp phm Shift thay oi o sang (phm len xuong) va tng phan (phm trai phai)

IF1A IF2 IF1B IF3 Module slot Relay output mot tiep iem Digital output

Cong RS232 noi PLC Cong RS232 noi may tnh, may in, HMI Cong RS422/485 noi PLC Cong RS422/485 cha dung Dung cho the nh PCMCIA Noi vi en bao hay coi Option

2.2 Man hnh cua OP 25 OP 25 co the hien th o hoa, o th ng cong, thanh, cac ky t ch so, nhap xuat d lieu so. Xet v du dung OP trong day chuyen ong hop nc trai cay. Nc trai cay gom ba thanh phan c tron lai sau o ong chai, dan nhan