You are on page 1of 1

Bundy Refrigeration Jaszarokszallas

CUSTOMER REJECTS OF MARIESTAD WOT CONDENSERS

BHU-GL 94858 5/8/2012

TREND DIAGRAM
120000
PPM Target

PARETO
120.00% 100.00%
Last 10 days % Cummulative %

100000

Date Check Bad PPM Targe

80000

80.00%
PPM 60000

40000

%
20000 0

60.00%

40.00%
20.00% 0.00% O G
DATE
Corrective action list

D N

H M P Q R

Y AK

FAILURES

Datas

11.18

11.22

11.23

11.24

11.25

11.26

11.29

11.30

12.01

12.02

12.03

12.06

12.08

12.09

12.10

12.13 4

# O G L A C J E D N I K B F H M P Q R S T X Y Z

Failure description Other Transport damage Loose wire middle (5) Slanting wire Welding defects Loose wire bottom-left (3) Caps are missing Painting defects Loose wire right side (2-4) Loose wire top-right (2) Loose wire bottom right (4) Wire is missing Rust Loose wire top-left (1) Loose wire left side (1-3)

Cause

Action

Resp.

Date

OK

O G 5 L 11 7 A 3 3 C 1 J 2 E 3 4 D 6 N 61 I 4 3 K 9 B F H M P Q R S T X Y Z

2 2 1 3 10 3 2 1 2 1 4 1 1 4 14 1 1 2 1

1 2 1

1 6 252 1 4 3 2 10 3 3 2 1 4 3 1 2 1 3 4 1 1 1

5 12 2 1 3 1 4

1 1

7 2 1 1

45 12 5 21 11 1 2 1 1 2 1

2 1 1

PAGE 1 / 1

QUALITY OPERATING SYSTEM

12.14

You might also like