Firesteel Intumescent Paint Protection to Structural Steel

Guidance for Painting Connection Bolts


Sheradised Fixings
Sheradising forms a very thin film zinc oxide (as opposed to galvanising that provides a zinc rich surface). It is therefore acceptable to wash and rinse the bolt to remove the oxide using Hempel Light Clean 99350 as per manufacturers instructions. Dry and apply intumescent basecoat within four hours (otherwise zinc oxide will reform). As part of your quality procedure, we recommend that trial adhesion check be carried out to a sample area.

Galvanised Fixings
If bolt is galvanised, it should be cleaned using Hempel Light Clean 99350 (diluted) and primed with Hempadur 15552 prior to application of intumescent.

Steel Fixings
Steel fixings can be primed using site 'touch up' primer or, if light rusting has occured, a surface tolerant primer such as Hempadur 45880 should be used prior to application of intumescent.

Firetherm Intumescent & Insulation Ltd, Unit F, Acorn Industrial Park, Crayford Road, Crayford, Kent. DA1 4FT. Tel: +44 (0)1322 551010. Fax: (0)1322 552727. Website: www.firetherm.com In presenting this technical advice we cannot claim to serve in any but an advisory capacity and can undertake no liability since actual conditions of use are beyond our control. Our Standard Terms & Conditions Apply At All Times