Professional Documents
Culture Documents
Double Pipe Design
Double Pipe Design
Annulus
di
do
di feet
1.38
1.66
0.115
2.469
2.88
0.20575
do feet
De
De'
a
a'
Number of
hairpins
Length
Total
length
W
Hot temp
Cold temp
0.138333333
0.115
0.115
0.010386891
0.435
4
0.24
0.16768881
0.06741667
0.01821884
20
160
20
160
7486.11
100
70
10000
150
130
LMTD
del t1
del t2
24.66303462
30
20
Cp
vis
k
density
Q
0.48
4.235
0.081
50.3125
107799.984
0.539
1.0164
0.078
44.375
107800
0.405465108
G
Nre
Npr
Nre0.8
Npr0.33
h
hio
Uc
Rd
Ud
A
A actual
Ud actual
Rd actual
720726.7515
19571.09242
25.0962963
2712.014794
2.927767223
151.0009019
125.5308703
80.2096433
0.004
60.72630292
71.97726532
69.6
62.80047725
0.003456117
548882.275
90556.2897
7.02358462
9237.08407
1.91507714
222.16491
Pressure drop
G
Nre
Nre0.42
f
sqr G
g
720726.7515
19571.09242
63.4568235
0.007660309
5.19447E+11
418000000
Hot
stream
W
10000
Hot temp 150
Cold
130
temp
Cp
0.539
vis
1.0164
k
0.078
density
44.375
Q
107800
548882.275
36406.7428
82.3562127
0.00670559
3.0127E+11
418000000
den sqr
2531.347656 1969.14063
delta P
3.656158752 3.59005228
V
3.43588278
V sqr
11.8052905
delta
P
0.73324786
entrance
and exit
Total delta 3.656158752 4.32330014
P
Cold
stream
7486.11
100
70
0.48
4.235
0.081
50.3125
107800