You are on page 1of 1

RESIN TABLE

PARAMETERS Resin Regenerant SAC Na+ NaCl WAC HCl SAC H+ H 2SO4/HCl WBA NaOH SBA type1 NaOH SBA type 2 NaOH

Capacity gm CaCO3/L (co Flow Regeneration) Capacity gm CaCO3/L (counter current regeneration) Regenerant level gm/litre Backwash rate M/Hr Regenerate injection Rate BV/Hr Regenerant strength % Displacement volume BV Rinse Volume BV Minimum flow velocity M/Hr

40--70

60-80

40-60

40 60

20-30

30-40

50-75

30-35

60-200

45-65

40-140

40-65

60- 180

50-160

8-12

8-10

8- 12

2- 5

5-8

5-8

4-7 10-15 2-4

4-8 1-4 1-3

4- 7 4-10 2-4

2-5 1-4 1-3

2-5 4-7 2-4

2-5 4-7 2-4

5-8

3-5

5-8

3-5

6-10

6-10

Regenerant strength mentioned in the table is only for HCl regeneration in case of SAC H+ . For H2SO4 Regeneration the regeneration is done in two stages to avoid precipitation. Datas mentioned in the table are just for guidance. It is best to use the resin suppliers recommended datas Because the datas in the table has been taken from various resin suppliers and is more of average value. These datas are good for first calculation. We Have put the fonts in table in blue colour because it would be best for you to change values to resin

You might also like