Memu Analysis

You might also like

You are on page 1of 3

Memu Analysis Trong hp thoi : Analysis Options 1.

Th: General - Voltage Thresholds: Ngng in p (pu) - Rating Limits: Gii hn nh mc Branch rating index: Ch s nh mc nhnh. Loading: Ph ti Power factor limit: Gii hn h s cng sut - MWH Load Linearization: Ti tuyn tnh MWH Linearize by Tree: Tuyn tnh theo cy Linearize by Group: Tuyn tnh theo nhm - Create PSS/Engines hub file: To tp tin PSS/Engine c dng network.dmp - Apply Scale Factor: p dng h s t l - Voltage Unbalance: in p khng cn bng Percent difference between max and min phase voltage: Phn trm khng cn bng gia in p pha cc i v in p pha cc tiu Percent difference between max and average phase voltage: Phn trm khng cn bng gia in p pha cc i v in p pha trung bnh Ratio of negative-sequence to positive-sequence voltage: T l in p th t nghch n in p th t thun. Percent difference between phase and average voltage: Phn trm khng cn bng gia in p pha v in p trung bnh Voltage upper limit: Gii hn trn ca in p - Current Unbalance: Dng in khng cn bng Percent difference between max and average phase current: Phn trm khng cn bng dng in pha cc i v dng in pha trung bnh Ratio of zero-sequence to positive-sequence current: T l dng in th t khng n dng in th t thun. Ratio of negative-sequence to positive-sequence current: T l dng in th t nghch n dng in th t thun. Current upper limit: Gii hn trn ca dng in.

2. Th: Load Flow - Convergence: S hi t Stop calculation affter ..iterations: Dng tnh ton sau .. bc lp Voltage precision: chnh xc in p (pu) Power precision: chnh xc cng sut (pu) Validate network before solving: Xc nhn mng trc khi gii Transformer taps locked: Kha r nhnh my bin p Capacitor locked: Kha t b Show detailed convergence information: Hin th chi tit thng tin hi t Graphical convergence monitor: Hin th th hi t Polar plot radius: th c cc hnh tia Monitored node: Kim sot nt Voltage phase: in p pha 3. Short Circuit Use transient machine impedance: S dng tr khng my thong qua Use subtransient machine impedance: S dng tr khng my cn qu Impedance for phase-to-ground faults (Ohms): Tr khng i vi s c pha chm t (). Fault all types: Tt c cc loi s c 3 phase-to-ground: 3 pha chm t Phase-to-round: 1 pha chm t Phase-to-round through impedance: 1 pha chm t qua tr khng Phase-to-phase: Pha chm pha Phase-to-phase-to-ground: Pha chm pha chm t Ungrounded 3-phase: Cch t 3 pha 4. Motor Starting 5. Reports Enable Update: Kch hot cp nht Branch Reports: Bo co cc nhnh Shunt Reports: Bo co cc mch r Node Reports: Bo co cc nt Harmonics Reports: Bo co cc sng hi Fault All Reports: Bo co tt c cc s c

6. CAPO (Optimal Capacitor Placement) Connection type (Wye/Delta) : Kiu kt ni (Sao/Tam gic) Load snapshots to consider: Xem xt biu ph ti Fixed Capacitor Placement: V tr b c nh (B nn) Switched Capacitor Placement: V tr b thay i (B ng ng) Number of banks available: S b t kh dng 3 phase bank size (kVAR): Dung lng b t 3 pha Eligible nodes: Chn nt thch hp 7. TOPO (Tie Open Point Optimization) Consider branch overload limits: Xem xt gii hn nhnh qu ti Selected rating index: La chn ch s nh mc Load snapshots to consider: Xem xt biu ph ti 8. DRA (Distribution Reliability Analysis) kW per customer: kW trn 1 khch hng Solution Target Values: Gi tr mc tiu gii php Display messages in progress window:Hin th thng bo trong ca s tin . 9. Harmonics Result Display: Hin th kt qu Maximum THD: THD cc i Harmonics Number: S lng sng hi Range (TIF, THD): THD (Total Harmonic Distortion): Bin dng sng hi tng TIF (Telephone Influence Factor): nh hng h s in thoi.

You might also like