MEDICAL/SURGICAL TUBING F O R M U L AT I O N S - 5 0 - H L
Sets the standard for performance and durability in the extracorporeal circuit and other blood contact applications
with Blood
Flexible and Resilient
Tygons unparalleled reputation for consistent performance is the result of controlling each formulation ingredient.
Criteria
TYPICAL APPLICATIONS INCLUDE:
equipment. Final product inspection can include flow rate testing, burst testing and measurement of other key performance characteristics in Nortons own testing laboratory.
DOCUMENTED BIOCOMPATIBILITY
Demonstrating consistency in material from lot to lot once a medical device or drug is marketed is increasingly important. That is why Norton is the first to fully characterize its medical tubing to the latest ISO 10993 standards and FDA guidelines for biocompatibility. (Refer to the Norton Medical/Healthcare brochure for additional details). Additionally, Tygon S-50-HL tubing fully complies with the requirements of USP XXIII Class VI Criteria and is non-toxic, non-hemolytic and non-pyrogenic.
Minimally Invasive Devices Medical Laboratories Blood and I.V. Solutions Dialysis Equipment Wound Drainage Inhalation Equipment Chemotherapy Drug Delivery Pharmaceutical Handling
AAX00001 AAX00002 AAX00003 AAX00004 AAX00005 AAX00006 AAX00007 AAX00009 AAX00010 AAX00011 AAX00012 AAX00013 AAX00014 AAX00016 AAX00017 AAX00018 AAX00019 AAX00022 AAX00023 AAX00024 AAX00027 AAX00028 AAX00029 AAX00032 AAX00033 AAX00034 AAX00036 AAX00037 AAX00038 AAX00041 AAX00045 AAX00046 AAX00047 AAX00053 AAX00059 AAX00062 AAX02002 AAX02003 AAX02004 AAX02006 AAX02007 AAX02011 AAX02012 AAX02017 AAX02018 AAX02022 AAX02027 AAX02028 AAX02029 AAX02037 AAX02038
D149-93 620
Unless otherwise noted, all tests were conducted at room temperature (73F). Values shown were determined on 0.075" thick extruded strip or 0.075" thick molded ASTM plaques or molded ASTM durometer buttons.
TYGON S-50-HL TOXICOLOGICAL PROFILE The biocompatibility of Tygon S-50-HL has been tested and found to be non-toxic in the following test protocols:
USP Systemic Toxicity and Intracutaneous Reactivity USP Intramuscular Implant MEM Elution Method Hemolysis, ASTM Method Mucosal Irritation (Extract Vaginal) Sensitization or Allergenicity, Maximization Method Ames Mutagenicity USP Physico Chemical Tests USP Bacteriostasis / Fungistasis Limulus Amebocyte Lysate (LAL) Inhibition Test USP Pyrogen Test
Copies of test data are available upon request.
The values listed for working and burst pressures are derived from tests conducted under controlled laboratory conditions. Many factors will reduce the tubings ability to withstand pressures including temperature, chemical attack, stress, pulsation and the attachment to fittings. It is imperative that the user conduct tests simulating the conditions of the application prior to specifying the tubing for use.
Distributed By:
Norton Performance Plastics Corporation P.O. Box 3660, Akron, OH 44309-3660 330-798-9240 800-798-1554 FAX: 330-798-6968 www.tygon.com
IMPORTANT: It is the users responsibility to ensure the suitability and safety of Norton tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. For a period of 6 months from the date of first sale, Norton Performance Plastics Corporation warrants this product to be free from defects in materials and workmanship. Our only obligation will be to replace any portion proving defective, or at our option, to refund the purchase price thereof. User assumes all other risk, if any, including the risk of injury, loss or damage, direct or consequential, arising out of the use, misuse, or inability to use, this product.THIS WARRANTY IS IN LIEU OF THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. No deviation is authorized. Norton Performance Plastics Corporation assumes no obligations or liability for any advice furnished by it, or for results obtained with respect to those products. All such advice is given and accepted at the buyer's risk. FLS51A-5M299CERT 1998 Norton Performance Plastics Corporation Printed in U.S.A. Tygon Norton Co. Reg.TM