You are on page 1of 37

BURNDY

Mechanical
TYPE KSU
UNIVERSAL SERVIT
For All Combinations of
Copper, Alum.,
ACSR, AAAC, 5005, and Steel
Tin-plated, high strength copper alloy
SERVIT with spacer. Spacer separates dissimilar conductors and provides long contact
length that prevents high pressure point
contacts between run and tap conductors.
486A
Copper Only

Use of PENETROX joint compound recommended with Aluminum and ACSR.

CONDUCTOR

RUN
CATALOG
CROSS
NUMBER FIG. FLAT
KSU17
KSU20
KSU22
KSU23
KSU25
KSU26
KSU27
KSU29
KSU31

2
2
2
2
2
2
1
1
1

.62
.69
.74
.81
.93
1.04
1.38
1.38
1.69

KSU34

2.00

COPPER &
ALUMINUM

.92
1.05
1.25
1.48
1.77
1.93
2.34
2.50
2.88

TAP
ACSR AAAC
5005

COPPER &
ALUMINUM

ACSR AAAC
5005

.42 12 SOL. - 6 SOL.


8 (6-1)
12 SOL. - 6 SOL.
8 (6-1)
.48 10 SOL. - 4 SOL.
6 (6-1)
10 SOL. - 4 SOL.
6 (6-1)
.57 10 SOL. - 2 SOL.
6 (6-1) - 4 (7-1)
10 SOL. - 2 SOL.
6 (6-1) - 4 (7-1)
.59
8 STR. - 2 STR.
3 (6-1) - 2 (6-1)
8 SOL. - 2 STR.
6 (6-1) - 2 (6-1)
.70 2 STR. - 1/0 STR.
3 (6-1) - 1 (6-1)
10 STR. - 1/0 STR.
6 (6-1) - 1 (6-1)
.79 1/0 STR. - 2/0 STR. 1 (6-1) - 1/0 (6-1) 8 STR. - 2/0 STR. 6 (6-1) - 1/0 (6-1)
1.12 1 STR. - 3/0 STR. 1 (6-1) - 2/0 (6-1) 8 SOL. - 3/0 STR. 8 (6-1) - 2/0 (6-1)
1.14
1 STR. - 250
2/0 (6-1) - 4/0 (6-1)
8 STR. - 250
6 (6-1) - 4/0 (6-1)
1.36
4/0 STR. - 350
3/0 (6-1) - 4/0 (6-1)
4 STR. - 350
4 (6-1) - 4/0 (6-1)
336 (30-7) - 477
3.12 1.47
400 - 500
2 STR. - 500
2 (6-1) - 477 (18-1)
(18-1)

Accommodates compressed conductors within conductor


ranges.
See note page A-2

MAXIMUM
CONDUCTOR
STEEL
RECOMMENDED
SOL. 3 STR. NOM
TIGHTENING
BWG BWG DIA. TORQUE in-lb.
8
6
4

8
6
4

5/32
7/32
1/4
5/16
3/8
7/16
1/2
1/2
5/8

275
275
385
385
500
650
650

825

165

BURNDY
Mechanical
TYPE BGBL
LAY-IN QIKLUG
A-15

*UL LISTED 90 C, 600 V


The Lay-In QIKLUG, Type BGBL is manufactured from high strength 6061-T6
aluminum, and is ideally suited for grounding
and bonding applications accommodating
both copper and aluminum conductor sizes
#14 AWG to 250 kcmil.

Fig. 1

Features and Benefits


* UL 486B listed, AL9CU rated.
For copper and aluminum conductor
combinations up to 90 C, 600 Volt
applications.
UL Recognized for grounding and bonding.
Ensures reliability.
Electro-tin plated.
Provides low contact resistance.
Lay-in feature.
Eases installation.

Fig. 2

DIMENSIONS
CATALOG
NUMBER

FIG
NO.

CONDUCTOR
RANGE

4 - 14 AWG

BGBL-1/0

1/0 - 14 AWG

BGBL-250

250 kcmil - 6

*BGBL-4

H
REF

.39
[10]
.63
[16]
.88
[22]

.62
[16]
.80
[20]
1.18
[30]

.48
[12]
.83
[21]
1.00
[30]

.79
[20]
1.16
[29]
1.72
[44]

J
1/4 - 28
3/8 - 24
7/16 - 18

NOTE: PEN-A PENETROX inhibitor is recommended for all


aluminum terminations.

TYPE CL50-1
COPPER LAY-IN QIKLUG
FOR COPPER
The Lay-In QIKLUG is manufactured from
high strength pure electrolytic copper to
ensure maximum strength and conductivity.
UL467 Listed for direct burial in earth or concrete. The open-faced design allows for fast
lay-in of the conductor without the need for
cutting or breaking.

CATALOG
NUMBER
CL50-1

WIRE RANGE
COPPER

STUD HOLE

#14 - #4 CU

#10

K
DIA.

.22
[6]
.28
[7]
.28
[7]

1.10
[28]
1.63
[41]
2.18
[55]

.20
[5]
.44
[11]
.45
[11]

.13
[3]
.19
[5]
.25
[6]

HEX
SIZE
SLOT
SLOT
7/32

BURNDY
Mechanical
TYPE QPX-Y
UNIVERSAL VERSITAP
A-10

Universal Parallel Clamp


For Copper and Aluminum
High copper alloy cast connector, tin-plated for
use with copper or aluminum cable. Makes
parallel, tap, tee, cross or end-to-end connections. Edges rounded for easy taping.
PENETROX joint compound recommended.

Fig. 1

CATALOG
NUMBER
QPX2C2C-Y
QPX282C-Y
QPX2828-Y
QPX342C-Y
QPX3428-Y
QPX3434-Y
QPX4444-Y

CONDUCTOR
ALUMINUM OR COPPER
RUN
TAP
6 STR. - 2 STR.
1/0 STR. - 4/0 STR.
1/0 STR. - 4/0 STR.
250 - 500
750 - 1000

6 STR. - 2 STR.
6 STR. - 2 STR.
1/0 STR. - 4/0 STR.
6 STR. - 2 STR.
1/0 STR. - 4/0 STR.
200 - 500
750 - 1000

FIG. NO.

Fig. 2

H
1-5/8
1-7/8
2
2-1/4
2-1/2
2-7/8
3-7/8

1
1
2
2

5/16

1-1/2

3/8
5/16

2
1-1/2
2
2-1/2
3-1/2

3/8
1/2

W
1-5/8
1-7/8
2-1/8
2-1/8
2-1/2
2-5/8
3-1/2

Listed torque values are for maximum conductor


combinations accommodated. Consult UL486
Tables 7 4, 7-5 7-6 for smaller conductor
combinations.
See note page A-2.

APPLICATION
VARIATIONS
PARALLEL

TAP

CROSS

TEE
SPLICE

RECOMMENDED
TIGHTENING
TORQUE in-lb
150
250
375
500

BURNDY
Mechanical
TYPES KA-U, KKA-U
UNIVERSAL TERMINAL
A-24

(One Conductor) For Aluminum


and Copper Conductors
These dual-rated one-conductor lugs are
constructed from high strength aluminum
alloy and electro tin-plated to provide low
contact resistance.

Fig. 1

Fig. 2

AL9CU

Fig. 3

CATALOG
NUMBER*

FIG.
NO.

WIRE RANGE
ALUMINUM OR
COPPER

KA6U
KA2U
KA25U
KA26U
KA29U
KA30U
KA31U
KA34U
KA36U
KA40U
KA44U
KKA31U-2N
KA36U-2N
KA40U-2N
KA44U-2N

1
1
1
2
2
2
2
2
2
2
2
3
4
4
4

14 STR. - 6 STR.
14 STR. - 2 STR.
14 STR. - 1/0 STR.
6 STR. - 2/0 STR.
6 STR. - 250
6 STR. - 300
6 STR. - 350
4 STR. - 500
2 STR. - 600
300 - 800
500 - 1000
6 STR. - 350
2 STR. - 600
300 - 800
500 - 1000

* "N" indicates NEMA standard stud holes.


Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.
** Maximum dimension.

STUD
HOLE
SIZE
1/4

5/16
3/8
1/2

1/2

.63
.63
.81
.81
.94
.94
1.03
1.50
1.72
1.69
1.69
3.16
3.22
3.03
3.03

1.06
1.16
1.50
1.47
2.00
2.00
2.25
2.81
3.19
3.38
3.38
5.50
4.69
4.75
4.75

Fig. 4

DIMENSIONS
**
N
W
E
.25
.31
.44
.47
.50
.50
.88
.88
.78
.88
.88
.63
.63
.63
.63

.50
.50
.63
.63
1.00
1.00
1.13
1.51
1.50
1.75
1.75
1.25
1.50
1.75
1.75

1.75
1.75
1.75
1.75

**
H

RECOMMENDED
TIGHTENING
TORQUE in-lb

.09
.10
.19
.19
.25
.25
.25
.31
.44
.50
.50
.38
.44
.50
.50

.50
.55
.80
.80
1.13
1.12
1.25
1.58
1.56
1.94
1.94
1.50
1.57
1.94
1.94

45
50
50
120
275
275
375
500
500
500
600
375
500
500
600

BURNDY
Mechanical
TYPE K2A-U
UNIVERSAL TERMINAL
A-25

(Two Conductor)
For Aluminum and
Copper Conductors
Fig. 1

These dual-rated two-conductor lugs are constructed from high strength aluminum alloy
and electro tin-plated to provide low contact
resistance.

Fig. 2

Fig. 3

CATALOG
NUMBER*

FIG.
NO.

WIRE RANGE
ALUMINUM OR
COPPER

K2A25U
K2A26U
K2A29U
K2A31U
K2A36U
K2A40U
K2A44U
K2A31U-2N
K2A36U-2N
K2A40U-2N
K2A44U-2N

1
2
2
2
2
2
2
3
3
3
3

Two: 14 STR. - 1/0 STR.


Two: 14 STR. - 2/0 STR.
Two: 6 STR. - 250
Two: 4 STR. - 350
Two: 2 STR. - 600
Two: 300 - 800
Two: 500 - 1000
Two: 6 STR. - 350
Two: 2 STR. - 600
Two: 300 - 800
Two: 500 - 1000

* "N" indicates NEMA standard stud holes.


Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.
** Maximum dimension.

STUD
HOLE
SIZE
1/4
3/8
1/2
5/8

1/2

.81
.81
1.50
1.69
1.75
1.66
1.66
3.00
3.22
3.03
3.03

1.47
1.47
2.56
2.88
3.20
3.38
3.50
4.50
4.69
4.75
4.75

DIMENSIONS
**
N
W
E
.44
.44
.50
.88
.63
.88
.88
.63
.63
.63
.63

1.13
1.25
1.66
1.94
2.41
3.19
3.52
2.31
2.41
3.19
3.19

1.75
1.75
1.75
1.75

**
H

RECOMMENDED
TIGHTENING
TORQUE in-lb

.19
.19
.25
.25
.44
.50
.50
.31
.44
.50
.50

.79
.79
1.20
1.25
1.58
1.94
1.94
1.38
1.56
1.94
1.94

50
50
275
275
375
375
375
275
375
375
375

BURNDY
Mechanical
TYPES K3A-U, KK3A-U
UNIVERSAL TERMINAL
A-26

(Three Conductor)
For Aluminum and
Copper Conductors
Fig. 1

Dual-rated three-conductor lugs are constructed from high strength aluminum alloy
and electro tin-plated to provide low contact
resistance.

Fig. 2

AL9CU

Fig. 3

CATALOG
NUMBER*
K3A2U-2*
K3A25U-2*
K3A26U-2N
K3A27U-2N
K3A29U-2N
K3A31U-2N
K3A36U-2N
KK3A36U-2N
KK3A40U-2N
KK3A44U-2N

FIG.
NO.

WIRE RANGE
ALUMINUM OR
COPPER

1
1
3
3
3
3
3
2
2
2

Three: 14 STR. - 2 STR.


Three: 14 STR. - 1/0 STR.
Three: 14 STR. - 2/0 STR.
Three: 6 STR. - 3/0 STR.
Three: 6 STR. - 250
Three: 6 STR. - 350
Three: 2 STR. - 600
Three: 2 STR. - 600
Three: 300 - 800
Three: 500 - 1000

* Slotted screw.
** N indicates NEMA standard stud holes.
Listed torque values are for maximum conductor sizes
accommodated.
Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor
sizes. All 4N items
See note page A-2

STUD
HOLE
SIZE

11/32
7/16

5/16
3/8

9/16

1/2

1.63
2.09
3.06
3.00
3.00
3.00
3.22
3.00
3.03
3.34

2.19
2.91
3.75
3.88
4.00
4.31
4.69
5.63
5.69
6.19

DIMENSIONS
N
W
E

.34
.34
.63
.63
.63
.63
.63
.56
.63
.63

.19
.25
.19
.31
.31
.31
.44
.44
.50
.56

.62
.88
1.79
1.12
1.19
1.38
1.56
1.69
1.94
1.88

1.59
1.94
1.95
2.81
2.81
3.00
3.63
4.22
4.81
4.75

.88
1.00

1.75

RECOMMENDED
TIGHTENING
TORQUE in-lb
50

275

375

BURNDY
Mechanical
TYPES K3A-U, KK3A-U
(Continued)
A-27

AL9CU

Fig. 1

Fig. 2

Fig. 3

CATALOG
NUMBER**

FIG.
NO.

WIRE RANGE
ALUMINUM OR
COPPER

K3A2U-4*
K3A25U-4*
K3A27U-4N
K3A29U-4N
K3A31U-4N
K3A36U-4N
K3A40U-4N
KK3A36U-4N
KK3A40U-4N
KK3A44U-4N

3
3
3
3
3
3
3
4
4
4

Three: 14 STR. - 2 STR.


Three: 14 STR. - 1/0 STR.
Three: 6 STR. - 3/0 STR.
Three: 6 STR. - 250
Three: 6 STR. - 350
Three: 2 STR. - 600
Three: 300 - 800
Three: 2 STR. - 600
Three: 350 - 800
Three: 500 - 1000

* Slotted screw
** N indicates NEMA standard stud holes.
Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.
All 4N items
See note page A-2

STUD
HOLE
SIZE

11/32
7/16

5/16
3/8

9/16

1/2

Fig. 4

1.63
2.09
3.00
3.00
3.00
3.22
3.03
3.00
3.34
3.34

2.19
2.91
3.88
4.00
4.31
4.69
4.75
5.63
6.19
6.19

DIMENSIONS
N
W
E
.34
.34

.63

1.59
1.94
2.81
2.81
3.00
3.63
4.81
4.22
5.34
4.75

.88
1.00

1.75

.19
.25
.31
.31
.31
.44
.50
.44
.56
.56

.62
.88
1.12
1.19
1.38
1.56
1.94
1.69
1.88
1.88

RECOMMENDED
TIGHTENING
TORQUE in-lb
50
275

375
275
375

BURNDY
Mechanical
TYPES K4A-U, KK4A-U
UNIVERSAL TERMINAL
A-28

(Four Conductor)
For Aluminum and
Copper Conductors
Fig. 2

Fig. 1

These dual-rated four conductor lugs are


constructed from high strength aluminum
alloy and electro tin-plated to provide low
contact resistance.

AL9CU

CATALOG
NUMBER*
K4A29U-4N
K4A31U-4N
KK4A36U-4N
KK4A40U-4N

WIRE RANGE
ALUMINUM OR
COPPER

FIG.
NO.
1
1
2
2

Four: 6 STR. - 250


Four: 6 STR. - 350
Four: 2 STR. - 600
Four: 300 - 800

STUD
HOLE
SIZE
1/2

DIMENSIONS
N
W
E

3
3
3.34
3

4
4.31
5.63
6.19

3.69
5.04
5
6

.63

1.75

.31
.31
.44
.56

1.19
1.38
1.69
1.88

RECOMMENDED
TIGHTENING
TORQUE in-lb
275
375

* N indicates NEMA standard stud holes.


All 4N items
See note page A-2

TYPES K11A-U,
K21A-U, K22A-U

Fig. 3

Fig. 2
Fig. 1

UNIVERSAL TERMINAL
For Aluminum and
Copper Conductors
Fig. 5

Fig. 4

Dual-rated panelboard lugs are constructed


from high strength extruded aluminum alloy
and electro tin-plated to provide low contact
resistance.
AL9CU

CATALOG
NUMBER*

FIG.
NO.

K11A30U*
K11A34U-2
K11A36U-2
K21A36U-2
K22A36U-2
K11A39U-2
K22A39U-2

1
2
3
4
5
3
5

WIRE RANGE
ALUMINUM OR
COPPER
Two: 6 STR. - 300
Two: 4/0 STR. - 500
Two: 2 STR. - 600
Three: 2 STR. - 600
Four: 2 STR. - 600
Two: 1/0 STR. - 750
Four: 1/0 STR. - 750

* Not CSA Listed.


Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for
smaller conductor sizes.

STUD
HOLE
SIZE
5/16
1/4

3/8

DIMENSIONS
N
W
E

.69

.31
.63

2.00
2.38

1.38

.75

3.00

.94

3.00
2.91

.47
.25

4.91

.38

2.31

1.00
1.44
1.50
2.50
2.50
1.69
3.06

RECOMMENDED
TIGHTENING
TORQUE in-lb
275

375

BURNDY
Mechanical
TYPE KAU-KIT
TRANSFORMER LUG KIT
A-29
These dual-rated lugs are constructed from
high strength aluminum alloy and electro tinplated to provide low contact resistance.
Lugs and mounting hardware packaged
together in these kits.

Features and Benefits


UL listed AL9CU dual rated set screw
terminals and CSA certified.
Ensure the transformer feeders and
taps are terminated properly.
Plated steel cap screws and hex nuts
with captive conical washers or individual
Belleville washers.
Terminal to bus connections are made
using proper hardware resulting in true
torque to pressure performance.
Compensates for dissimilar metal
expansion and contraction.

TERMINALS
CATALOG TRANSFORMER
CATALOG
NUMBER
KVA RATING QTY.
NUMBER
KAU-KIT1
KAU-KIT2
KAU-KIT3
KAU-KIT4

WIRE RANGE
ALUMINUM
OR COPPER

15 - 37.5
15 - 45
50 - 75
75 - 112.5
100 - 167
150 - 300

1
3
1
3
1
3

8
4

KA2U
KA29U

#14 - 2
#6 - 250

12

KA29U

#6 - 250

6
7

K2A31U
K2A40U

#6 - 350
300 - 800

400 - 500

15

K2A40U

300 - 800

QTY.

BOLT SIZE

1/4-20  3/4 HH

8
8
5
6
7
4

1/4-20  3/4 HH
1/4-20  2 HH
1/2-13  3 HH
1/2-13  2-1/2 HH
1/2-13  2
1/2-13  2-1/2

Hardware packed in plastic bag.


No lost hardware prior to installation.
Larger 800 kcmil lugs in KIT3 and KIT4.
Accommodates common 750 kcmil tap
conductors in larger transformers.

HARDWARE
QTY.
NUT

QTY.

WASHER

1/4  20 HN

Captive to Nut

16

1/4  20 HN

Captive to Nut

11

1/2-13 HN

11

1/2-13 HN

22
11
22
11

1/2 FW
1/2 Belleville
1/2 FW
1/2 Belleville

BURNDY
Mechanical
TYPE AMS
A-30

DUAL RATED
SPLICER/REDUCER
For Copper and
Aluminum Cable
All splicer/reducers are dual rated for use with
aluminum and copper conductors and are
constructed from high strength, tin plated
aluminum. PENTROX oxide inhibiting joint
compounds are recommended for all
aluminum applications.

CATALOG
NUMBER

WIRE RANGE
MAX.
MIN.

AMS-2*
AMS-0*
AMS-4/0
AMS-250
AMS-350
AMS-500
AMS-750
AMS-1000

2
1/0
4/0
250
350
500
750
1000

14
8
6
6
6
3/0
250
500

* Slotted Screws. H2 measured with maximum conductors,


reference only.
Complies with NFPA 78-86.

Features and Benefits


Large screw diameters.
Ensures greater surface contact with
wires for maximum pullout force.
Large cable ranges.
Each splice is also an effective
reducing connector.

All connectors are tin-plated.


Provide low contact resistance and
prevents galvanic corrosion.
Connectors feature rounded bottoms.
Facilitates taping.
Solid center barrier.
Prevents contact of dissimilar metals.

H1

H2 MAX.

NO. OF
SCREWS

SCREW
DIA.

HEX
SIZE

1-19/32
1-29/32
2-5/16
4-3/32
4-11/32
4-25/32
6-1/16
8-11/16

9/16
3/4
1
1
1
1-1/4
1-7/16
1-21/32

9/16
3/4
1-3/32
1-3/32
1-3/32
1-3/8
1-5/8
1-7/8

.79
.86
1.28
1.29
1.30
1.48
1.98
2.34

2
2
2
4
4
4
4
6

3/8
7/16
9/16
5/8
11/16
13/16
15/16
1-1/8

S
S
5/16
5/16
5/16
3/8
1/2
9/16

BURNDY
Mechanical
TYPE AGSKIT
ABOVE GRADE SPLICE KITS
A-31

For all Aluminum or


Copper/Aluminum
Combinations
Type AGS Above Grade Splice Kit consists of
a standard AMS splice/reducer and a heavy
wall heat-shrink sleeve. The AMS Splice is
dual rated for use with aluminum and copper
conductors and are constructed from high
strength, tin plated aluminum that provides
low contact resistance and reduces the
effects of galvanic corrosion. Connector is
installed with common installation tools. The
heavy wall heat shrink sleeve is lined with
adhesive material, providing a positive seal
against moisture egress. Heat shrink sleeve
is installed with standard propane torch, or
electric heat gun.

Fig. 1

Catalog
Number
AGSKIT2
AGSKIT250

Figure
Number
1
2

Fig. 2

Wire Range
Maximum Minimum
2
8
250
1

TYPE UGSKIT
WATERTIGHT/UNDERGROUND
SPLICE KITS
For all Aluminum or
Copper/Aluminum
Combinations
Type UGS Watertight Underground Splice Kit
consists of a standard AMS splice/reducer
and two heavy wall heat-shrink sleeves. The
AMS Splice is dual rated for use with
aluminum and copper conductors and are
constructed from high strength, tin plated
aluminum that provides low contact resistance and reduces the effects of galvanic
corrosion. Connector installed with common
installation tools. Both heavy wall heat shrink
sleeves are lined with adhesive material,
providing a watertight splice that can withstand abrasions that may occur during direct
burial applications. Heat shrink sleeve
installed with standard propane torch, or electric heat gun.

Fig. 1

Catalog
Number
UGSKIT2*
UGSKIT250*

Figure
Number
1
2

*UL486D Listed for Direct Burial

Wire Range
Maximum Minimum
2
8
250
1

Fig. 2

BURNDY
Mechanical
TYPE UGSKIT8
A-32

UF DIRECT BURIAL
SPLICE KIT
Type UGS UF Splice Kit consists of a UF
splice connector and a heavy wall heat-shrink
sleeve. The UF splice connector can accommodate up to four UF conductors and is
installed with common installation tools. The
heavy wall heat shrink sleeve is lined with an
adhesive material, providing a watertight
splice that can withstand abrasions that may
occur during direct burial applications. Heat
shrink sleeve installed with standard propane
torch, or electric heat gun.

Catalog
Number
UGSKIT8*

Wire Range
Copper
8 AWG 14 AWG

*UL486D Listed for Direct Burial

TYPE UGS350ULDB
IN-LINE SPLICE/REDUCER
For Direct Burial

Features and Benefits


EPDM rubber covered 6061-T6 aluminum
connector.
Dual rated AL9CU for copper or aluminum
conductor.
UL Listed and CSA Certified for Direct
Burial.
Broad range taking capability.
Low installation cost.

CATALOG
NUMBER
UGS350ULDB

WIRE RANGE
12 AWG - 350 kcmil

Dimensions in brackets [ ] are in millimeters.

LENGTH
In. [mm]

HEIGHT
In. [mm]

8.50
[216]

2.81
[71.4]

HEX SIZE

TORQUE
(In. Lbs.)

5/16

350

BURNDY
Mechanical
TYPE QGFL
BARTAP
A-33

For Copper Cable To Flat


High copper alloy BARTAP for joining a
range of cable to bar or pad. One-wrench
installation.

CATALOG
NUMBER
QGFL1CB1
QGFL1CB1T6
QGFL26B1
QGFL26B1T6
QGFL26B2*
QGFL26B2T6*
QGFL29B1*
QGFL29B1T6*
QGFL31B1*
QGFL31B1T6*
QGFL34B1
QGFL34B1T6
QGFL39B1
QGFL39B1T6
QGFL44B1
QGFL44B1T6
QGFL46B1
QGFL46B1T6
QGFL48B1
QGFL48B1T6

COPPER
CONDUCTOR
10 SOL. - 1 STR.

8 SOL. - 2/0 STR.

B
1-1/8
1-1/4
1-1/2

6 STR. - 250
1-5/8
2 SOL. - 350
1-3/4
1/0 SOL. - 500
2
350 - 750
750 - 1000
1000 - 1500

2-1/4

1500 - 2000

* Can be installed side by side or in-line on NEMA drilled bar.

H
1-7/8
2-3/8
2-1/8
2-5/8
2-1/2
2-1/8
2-5/8
3-1/8
2-7/8
3-1/4
3-1/8
3-5/8
3-1/4
3-5/8
3-3/8
4-1/8
4
4-1/2
5-1/4
5-1/4

J
3/8

1/2

T
(MAX.)
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4

W
1

1-1/8

1-3/8
1-5/8

1-3/4

2-1/8
2-1/2
3

BURNDY
Mechanical
TYPE FCB
A-34

TRANSFORMER
TAP ADAPTER
For Copper and Aluminum
Silver brazed 101% conductivity copper
transformer tap adapter designed to accommodate from 1 to 6 NEMA drilled copper or
aluminum terminal taps from a single
secondary transformer outlet. Tin-plated.
Order mounting hardware & tap terminals
separately.

Fig. 1

FIG.
NO.

CATALOG
NUMBER

A
DIA.

H
REF.

1
2
1
2
1
2

FCB63-4N
FCB63-6N
FCB64-4N
FCB64-6N
FCB65-4N
FCB65-6N
FCB63-2NP300
FCB64-44NP50

.50
.50
.75
.75
1.00
1.00
.50
.75

5.25
5.25
5.75
5.75
7.00
7.00
5.00
9.00

3.75
5.50
4.00
5.75
4.25
6.00
3.50
5.00

2.25
2.25
2.75
2.75
4.00
4.00
3.00
5.00

NOTE: All pads are NEMA drilled.

Fig. 2

BURNDY
Mechanical
TYPE KPU-AC
POLYTAP
A-35

Insulated Gutter Tap for All


Copper and Aluminum
Combinations
Wide range-taking tin-plated aluminum parallel clamp and insulating cover assembly for
industrial and multiple story structure applications. Only six connectors cover the entire 14
Sol.-750 kcmil range. Covers having flexible
fingers that conform to conductor, fully insulating the connection. UL486B listed for 600
volts maximum 90 C service. Cover and
connector are packaged together. No taping
required.
600 Volt Max. 90 C

CATALOG
NUMBER
KPU29A26AC
KPU29A29AC
KPU34A26AC
KPU34A34AC
KPU39A26AC
KPU39A39AC

CONDUCTOR
COPPER OR ALUMINUM
RUN
TAP
1/0 STR. - 250
1/0 STR. - 250
4/0 STR. - 500
4/0 STR. - 500
500 - 750
500 - 750

14 SOL. - 2/0 STR.


6 STR. - 250
14 SOL. - 2/0 STR.
6 STR. - 500
14 SOL. - 2/0 STR.
1/0 STR. - 750

RECOMMENDED
TIGHTENING
TORQUE in-lb

2-11/16

3-1/8

375

4-11/32

1-7/8

3-1/2

450

4-13/16

3-1/4

600

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6
for smaller combinations.
See note page A-2.

TYPE UCU-AC
RISER TAP
Parallel-groove riser tap and insulation cover
for copper and aluminum. Wide range-taking
assembly for apartment house and light
industrial applications. Cover and connector
are packaged together. Covers having insulating fingers that conform to conductors, fully
insulating the connection. UL486B Listed for
600 volts max. 90 C service.

600 VOLT MAX. 90 C MAX.

CATALOG
NUMBER
UCU28AC

CONDUCTOR
RUN
TAP
2 STR. - 4/0 STR.

10 SOL. - 2 STR.

Listed torque values are for maximum conductor


combinations accommodated. Consult UL486 Tables 7-4,
7-5, 7-6 for smaller combinations.

RECOMMENDED
TIGHTENING
TORQUE in-lb

2-1/4

1-13/16

2-5/8

120

BURNDY
Mechanical
TYPE BIPC
INSUL-TAP
A-36

UL Listed 90 C, *600 Volt


The INSUL-TAP, TYPE BIPC, Burndy
Insulation Piercing Connector is ideally suited
for splicing and tapping aluminum and copper
conductor wire sizes: #10 AWG to 500 kcmil.
The BIPC's unique insulation piercing design
allows for use on hot-line applications, eliminating the need for taping.

Features and Benefits


Insulation piercing capability.
Eliminates the need for conductor
insulation stripping.
UL486B listed, AL9CU rated.
For copper and aluminum conductor
combinations up to 90 *600 Volt
applications.
Insulation piercing design.
For use on hot-line applications.
Eliminates the need for taping.
Easy snap-out tabs.
Eases installation, protects connection
from dirt and debris.
Simple bolt-on connection.
Eases installation.

CATALOG
NUMBER
BIPC1/0-2
BIPC4/0-6
BIPC4/0-1/0
BIPC350-4/0
BIPC350-350
BIPC500-4/0

CONDUCTOR RANGE
RUN
TAP
1/0 - 8 AWG
[50 - 6 mm2]
4/0 - 1/0 AWG
[95 - 50 mm2]
4/0 - 1/0 AWG
[95 - 50 mm2]
350 - 4/0 AWG
[185 - 95 mm2]
350 - 4/0 AWG
[185 - 95 mm2]
500 - 350 kcmil
[240 - 185 mm2]

2 - 8 AWG
[35 - 6 mm2]
1/0 - 6 AWG
[50 - 16 mm2]
4/0 - 1/0 AWG
[95 - 50 mm2]
4/0 - 10 AWG
[95 - 6 mm2]
350 - 4/0 AWG
[185 - 95 mm2]
4/0 - 4 AWG
[95 - 25 mm2]

Fig. 1

BOLT
SIZE

SOCKET FIG.
SIZE
NO.

5/16-18

1/2

5/16-18

1/2

5/16-18

1/2

3/8-16

9/16

3/8-16

9/16

3/8-16

9/16

Fig. 2

DIMENSIONS
H
L
W
2.00
[51]
2.50
[64]
2.50
[64]
3.00
[76]
3.00
[76]
3.25
[83]

1.53
[39]
2.12
[54]
2.12
[2.12]
1.59
[40]
2.62
[67]
1.59
[40]

2.56
[65]
2.00
[51]
2.06
[52]
2.50
[64]
2.75
[70]
2.62
[67]

RECOMMENDED
TORQUE (N,m)
180 in. lbs.
[20.3 N.m]
250 in. lbs.
[28.3 N.m]
250 in. lbs.
[28.3 N.m]
375 in. lbs.
[42.4 N.m]
300 in. lbs.
[33.9 N.m]
400 in. lbs.
[45.2 N.m]

MAX.
VOLTAGE
RATING
600V
300V
300V
300V
300V
600V

BURNDY
Mechanical
SPEC-BLOK
POWER
DISTRIBUTION
CONNECTORS

A-37

Unique, modular, made-to-order, powerdistribution assemblies accommodate any


number of supply and load conductors in any
number of poles. Capacity matches the conductors accommodated and SPEC-BLOK
assures uniform loading.
Burndy will design, quote, assemble and
ship SPEC-BLOK especially constructed to
suit your particular requirements within
48 hours upon request.
Adjacent poles are separated by easy-tohandle, wrap-around insulating covers which
eliminate taping and reduce heat build-up by
allowing air to flow freely around connectors.
SPEC-BLOK is UL Listed for copper or
aluminum conductors for 600 volts. (AL9CU)
Assemblies are mounted on platforms suitable for easy installation in wireway or
junction box.

Features and Benefits


Accommodate unlimited conductors.
Fits wide range of applications.
Eliminates need for non-UL-listed
improvisation.
Connector elements tin-plated.
Provides high reliability, low-resistance
connections.
User friendly, space-saving design.
Easy to install. Saves labor.
94-VO rated insulation folds into place
insulating the components.
Saves time and material. Allows
easy installation.

Connector caps removable for easy


cable lay-in.
Saves labor. Makes installation easier.
Allows installation or straight-through
conductors. Eases retrofit.
Belleville washers built-in on pressure
screw assemblies, except in assemblies
installed with a 5/32" Allen wrench.
Provides high-integrity connections.
Conductors can be cut or fed straight
through.
Straight through installation ideal for
riser applications.

Contact Burndy or Technical Services, 1-800-451-4956


or Burndy Customer Service, 1-800-346-4175

BURNDY
Mechanical
SPEC-BLOK

Features and Benefits


The SPEC-BLOK system includes
12 connector elements
A wide variety of conductor sizes can
be accommodated
Each element can be bolted together
in parallel
Provides an efficient flow of current from
one element to another
AL9CU rated for Copper or Aluminum
conductors
Dual-rated system, with UL486Bs
highest temperature rating

A-38

2 Wire (series), 4 (parallel), and Multi-Tap


versions available
Nearly any conductor combination can
be terminated
Tin-plated Aluminum Alloy Construction
High-strength, corrosion-resistant
connector elements
All SPEC-BLOKs are custom made for
nearly any Power Distribution system
requirement
Time savings pre-assembled in our
factory for immediate installation!

SPEC-BLOK CONNECTORS

CATALOG DESIGNATION
(MAXIMUM
CONDUCTOR)

4
Conductor

2
Conductor

NUMBER OF
CONDUCTORS
ACCOMMODATED

4
Conductor

2
Conductor

AL or CU
WIRE RANGE UNDER
EACH CAP

DIMENSIONS
ALLEN
WRENCH
Second
SIZE
Conductor
Length Without Insulator
(if
Height On
First
Width
required)
Max
4
2
Conductors
May Be Conductors
Conductor Conductor
MUST Be
1/0-2/0

#12-2/0
2-9/16

1-1/2

2-1./8

7/8

3-1/8

1-11/16

4-1/4

1-3/8

5/32"

(2/0)
B

3/0-250

#6-250

(250)
C

S
(350)

1 to 4 (0, 1
or 2
per cap)

1 or 2
per cap

250-350

400-500

1/4"

#6-350
3-5/16

1-13/16

4-5/8

1-1/2

4-1/16

5-5/8

1-3/4

4-7/8

2-1/4

7-1/4

2-5/8

#6-500

(500)
E

600-750

3/8"

3/0-750

(750)

Catalog Designation Number of Conductors


(Maximum Conductor)
Accommodated
P (1/0)
1 to 8 (0, 1 or 2 under
each screw)
U (1/0 & 500)
2 to 9 (0, 1 or 2 under
each screw plus one
large conductor)
** This range may be expanded to include #8 provided two
conductors are being installed in that particular element.

Large
Groove

Small
Grooves**

Height On
Maximum
Conductors

Width

__

6-1/0

3 1/2

3/0-500

6-1/0

4 1/8

Length
Without
Insulator

Allen
Wrench
Size

1 3/4

5/32"

BURNDY
Mechanical
SPEC-BLOK
MOUNTING PLATFORMS
A-39
SPEC-BLOK Mounting Platforms are rigid
steel construction with a black finish. They
can be supplied for junction box mounting or
wireway construction allowing trough conductors to pass underneath the assemblies.

(CPB-)

(CPT-)

CATALOG
NUMBER

L
(Nominal)

L
(Overall)

W
(Overall)

CPB6
CPB8
CPB10
CPB12
CPB16-5/8
CPB21-1/4

6
8
10
12
16-5/8
21-1/4

7-3/4
9-3/4
11-3/4
13-3/4
18-3/8
23

2-1/2
2-1/2
2-1/2
3-1/2
3-1/2
3-1/2

CATALOG
NUMBER
CPT6
CPT8
CPT10
CPT12
CPT16

5-7/8
7-7/8
9-7/8
11-7/8
15-7/8

2-1/2
3-1/2
3-1/2
3-1/2
3-1/2

2-1/4
3
3-1/2
4
4

SPEC-BLOK catalog numbers describe exactly how the distribution block is assembled:
5DR-NDST-GQP-12
(assembly pictured)
5
DR

Total number of poles in the


completed assembly
One 'D' unit and one 'R' unit, bolted
in parallel, forming each phase pole
(3 phase poles)

Denotes the beginning of the neutral


pole (where required)
DST One 'D' unit, one 'S' unit, and on 'T'
unit, bolted in parallel, forming the
neutral pole
G
QP

12

Denotes the beginning of the ground


pole description (where required)
One 'Q' unit and on 'P' unit, bolted in
parallel, forming the ground pole.
Size (inches) of the wireway or trough
that is needed to enclose the assembly. If a junction box enclosure is used,
no number is used to denote the size
of the enclosure.

SPEC-BLOK IS A SYSTEM THAT CAN SOLVE MOST POWER DISTRIBUTION APPLICATIONS!

BURNDY
Mechanical
QUESTIONNAIRE
A-40

FOR SPEC-BLOK
OR ELECTRO-RAIL
APPLICATIONS
What is the total capacity of the system?_____________amps

Are any conductors continuous? Yes

How many poles in the system

If yes, which ones?____________________________________

(3-wire, 4-wire, single phase, etc.)?_____________poles

___________________________________________________

Are neutral conductors (when required) different sizes (AWG/KCMil)


than the phase conductors?

What kind of enclosure is connection assembly being mounted into


and what are inside space dimensions?

_________the same size

Trough size _________________________________________

__________different size

Is a ground connection required?

Yes

No

What are the quantities, sizes (AWG/kcmil) and material (Al/Cu)


of the incoming line conductors and outgoing load conductors?

No

Box, panel, cabinet, other size___________________________


When is a quotation required? Date:______________________
When is the material required? Date:_____________________

QUANTITY
LINE
PER
PHASE

SIZE

CONDUCTOR
TYPE
(Cu/Al)

Is there a preference for a particular


Burndy distributor? Yes No
If yes, give name, location & telephone Number:
Name:______________________________________________

LOAD
Address:____________________________________________
LINE
PER
NEUTRAL

__________________________________________________
LOAD
LINE

PER
GROUND
LOAD

Phone #:____________________________________________

BURNDY
Mechanical
3 WIRE BUS
ASSEMBLY
FOR TROUGH

A-41

(INSULATING COVERS AND


MOUNTING BASE INCLUDED)
Bus Assemblies consist of tin plated aluminum bus mounted to an insulating platform.
Each phase is separated with 94VO 600 volt
wrap-around adhesive insulations. The entire
assembly is mounted on a trough type base.

CATALOG
NUMBER
1300A-8-3-10
1300A-12-3-10
1300A18-3-10
1300A-24-3-10
1300A-30-3-10
1350A-8-3-12
1350A-12-3-12
1350A-18-3-12
1350A-24-3-12
1350A-30-3-12
1500A-12-3-10
1500A-18-3-10
1500A-24-3-10
1500A-30-3-10
1500A-12-3-12
1500A-18-3-12
1500A-24-3-12
1500A-30-3-12

AMP RATING
PER BUS
1300
1300
1300
1300
1300
1350
1350
1350
1350
1350
1500
1500
1500
1500
1500
1500
1500
1500

DIMENSIONS
LENGTH
BUS
INSULATION
8
12
18
24
30
8
12
18
24
30
12
18
24
30
12
18
24
30

12
16
22
28
34
12
16
22
28
34
16
22
28
34
16
22
28
34

WIDTH

HEIGHT

WEIGHT

PCS. PER CTN.

10
10
10
10
10
12
12
12
12
12
10
10
10
10
12
12
12
12

4.75
4.75
4.75
4.75
4.75
5.25
5.25
5.25
5.25
5.25
4.75
4.75
4.75
4.75
5.25
5.25
5.25
5.25

8 lbs.
11 lbs.
15 lbs.
22 lbs.
26 lbs.
9 lbs.
12 lbs.
16 lbs.
23 lbs.
27 lbs.
15 lbs.
18 lbs.
27 lbs.
30 lbs.
16 lbs.
19 lbs.
28 lbs.
31 lbs.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

BURNDY
Mechanical

A-42

4 WIRE BUS
ASSEMBLY
FOR TROUGH
(INSULATING COVERS AND
MOUNTING BASE INCLUDED)

CATALOG
NUMBER
1350A-8-4-12
1350A-12-4-10
1350A-18-4-12
1350A-24-4-12
1350A-30-4-12
1500A-12-4-12
1500A-18-4-12
1500A-24-4-12
1500A-30-4-12

AMP RATING
PER BUS
1350
1350
1350
1350
1350
1500
1500
1500
1500

DIMENSIONS
LENGTH
BUS
INSULATION
8
12
18
24
30
12
18
24
30

12
16
22
28
34
16
22
28
34

WIDTH

HEIGHT

WEIGHT

PCS. PER CTN.

12
12
12
12
12
12
12
12
12

5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25

10 lbs.
13 lbs.
17 lbs.
26 lbs.
30 lbs.
18 lbs.
21 lbs.
30 lbs.
34 lbs.

1
1
1
1
1
1
1
1
1

BURNDY
Mechanical
WIRE BUS
ASSEMBLY FOR
JUNCTION BOXES

A-43

(INSULATING COVERS AND


MOUNTING BASE INCLUDED)

3 WIRE BUS ASSEMBLY


FOR JUNCTION BOXES
(INSULATING COVERS AND
MOUNTING BASE INCLUDED)
CATALOG
NUMBER
1350A-8-3-B
1350A-12-3-B
1350A-18-3-B
1350A-24-3-B
1350A-30-3-B
1500A-12-3-B
1500A-18-3-B
1500A-24-3-B
1500A-30-3-B

AMP RATING
PER BUS
1350
1350
1350
1350
1350
1500
1500
1500
1500

DIMENSIONS
LENGTH
BUS
INSULATION
8
12
18
24
30
12
18
24
30

12
16
22
28
34
16
22
28
34

WIDTH

HEIGHT

WEIGHT

PCS. PER CTN.

12
12
12
12
12
12
12
12
12

2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75

9 lbs.
12 lbs.
16 lbs.
23 lbs.
27 lbs.
15 lbs.
18 lbs.
27 lbs.
30 lbs.

1
1
1
1
1
1
1
1
1

WIDTH

HEIGHT

WEIGHT

PCS. PER CTN.

16
16
16
16
16
16
16
16
16

2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75

10 lbs.
13 lbs.
17 lbs.
26 lbs.
30 lbs.
18 lbs.
21 lbs.
30 lbs.
34 lbs.

1
1
1
1
1
1
1
1
1

4 WIRE BUS ASSEMBLY


FOR JUNCTION BOXES
(INSULATING COVERS AND
MOUNTING BASE INCLUDED)
CATALOG
NUMBER
1350A-8-4-B
1350A-12-4-B
1350A-18-4-B
1350A-24-4-B
1350A-30-4-B
1500A-12-4-B
1500A-18-4-B
1500A-24-4-B
1500A-30-4-B

AMP RATING
PER BUS
1350
1350
1350
1350
1350
1500
1500
1500
1500

DIMENSIONS
LENGTH
BUS
INSULATION
8
12
18
24
30
12
18
24
30

12
16
22
28
34
16
22
28
34

BURNDY
Mechanical
VERSI-POLE
A-44

POWER DISTRIBUTION
BLOCKS
VERSI-POLE Power Distribution Blocks
are designed to provide modular solutions to
power distribution applications. Each connector element is made from a high conductivity
aluminum alloy which is insulated with a high
strength polymer housing. One, two, and
three pole versions available. "Add" a pole
(snap-together) blocks are also available for
wire sizes up to 500 kcmil. For use with Cu or
Al. 600 V, AL9CU rated.

Features and Benefits


"Add" a pole feature available.
Provides capability to create as many
poles as required.
Up to 30 tap conductors accommodated.
Ideal for current distribution to multiple
locations.
Single or dual run connections.
Allows user to minimize the number
of connectors needed to do the job.

VERSI-POLE SNAPTOGETHER BLOCKS

Suitable for use with aluminum or


copper conductors.
Provides maximum versatility.
600 V, AL9CU rated.*
Meets or exceeds industry standard
requirements.
Dead-front covers available
Provides user protection one cover
per pole.
* BDB-430-500-1 not UL recognized or CSA certified

RUN
WIRE RANGE
AL9CU

TAP
WIRE RANGE
AL9CU

AMPERE
RATING PER
POLE

NUMBER OF
POLES

BDA-112-350

350 kcmil - 6

4 - 14

350

ADDER

BDA-16-350

350 kcmil - 6

2/0 - 14

350

ADDER

BDA-16-500

500 kcmil - 4

2/0 - 4

430

ADDER

BDA-26-350

350 kcmil - 6

2/0 - 14

700

ADDER

BDA-212-500

500 kcmil - 4

4 - 14

860

ADDER

BDA-26-500

500 kcmil - 4

2/0 - 14

860

ADDER

BDA-24-500

500 kcmil - 4

4/0 - 6

860

ADDER

BDA-11-500

500 kcmil - 4

500 kcmil - 4

430

ADDER

BDA-22-350

350 kcmil - 6

350 kcmil - 6

700

ADDER

BDA-22-500

500 kcmil - 4

500 kcmil - 4

860

ADDER

CATALOG
NUMBER

CONNECTOR
RUN

NOTES:
1. Order Optional BDB COVER1 per pole if desired.
2. Snap-together blocks can also be assembled to 1, 2, 3
pole blocks to create multi-pole distribution blocks.

TAP

BURNDY
Mechanical
VERSI-POLE
VERSI-POLE 1, 2, 3 POLE
DISTRIBUTION BLOCKS

A-45

RUN
WIRE RANGE
AL9CU

TAP
WIRE RANGE
AL9CU

AMPERE
RATING PER
POLE

BDB-16-2/0-1
BDB-16-2/0-2
BDB-16-2/0-3

2/0 - 12

4 - 14

195

1
2
3

BDBCOVER2

BDB-26-2/0-1
BDB-26-2/0-2
BDB-26-2/0-3

2/0 - 14

2 - 14

390

1
2
3

BDBCOVER2

BDB-112-350-1
BDB-112-350-2
BDB-112-350-3

350 kcmil - 6

4 - 14

350

1
2
3

BDBCOVER1

BDB-16-350-1
BDB-16-350-2
BDB-16-350-3

350 kcmil - 6

2/0 - 14

350

1
2
3

BDBCOVER1

BDB-14-500-1
BDB-14-500-2
BDB-14-500-3

500 kcmil - 4

2/0 - 14

430

1
2
3

BDBCOVER2

BDB-16-500-1
BDB-16-500-2
BDB-16-500-3

500 kcmil - 4

2/0 - 14

430

1
2
3

BDBCOVER1

BDB-162-500-1
BDB-162-500-2
BDB-162-500-3

500 kcmil - 4

2 - 14

430

1
2
3

BDBCOVER2

BDB-26-350-1
BDB-26-350-2
BDB-26-350-3

350 kcmil - 6

2/0 - 14

700

1
2
3

BDBCOVER1

BDB-212-500-1
BDB-212-500-2
BDB-212-500-3

500 kcmil - 4

4 - 14

860

1
2
3

BDBCOVER1

BDB-26-500-1
BDB-26-500-2
BDB-26-500-3

500 kcmil - 4

2/0 - 14

860

1
2
3

BDBCOVER1

BDB-24-500-1
BDB-24-500-2
BDB-24-500-3

500 kcmil - 4

4/0 - 6

860

1
2
3

BDBCOVER1

CATALOG
NUMBER

CONNECTOR
RUN
TAP

OPTIONAL
NUMBER OF COVER ORDER
POLES
1 PER POLE

BURNDY
Mechanical
VERSI-POLE
A-46

VERSI-POLE 1, 2, 3
SPLICE/REDUCER BLOCKS
RUN
WIRE RANGE
AL9CU

TAP
WIRE RANGE
AL9CU

AMPERE
RATING PER
POLE

BDB-11-2/0-1
BDB-11-2/0-2
BDB-11-2/0-3

2/0 - 14

2/0 - 14

195

1
2
3

BDBCOVER2

BDB-11-350-1
BDB-11-350-2
BDB-11-350-3

350 kcmil - 6

350 kcmil - 6

350

1
2
3

BDBCOVER2

BDB-11-500-1
BDB-11-500-2
BDB-11-500-3

500 kcmil - 6

500 kcmil - 6

430

1
2
3

BDBCOVER1

BDB-22-2/0-1
BDB-22-2/0-2
BDB-22-2/0-3

2/0 - 14

2/0 - 14

390

1
2
3

BDBCOVER2

BDB-22-350-1
BDB-22-350-2
BDB-22-350-3

350 kcmil - 6

350 kcmil - 6

700

1
2
3

BDBCOVER1

BDB-22-500-1
BDB-22-500-2
BDB-22-500-3

500 kcmil - 4

500 kcmil - 4

860

1
2
3

BDBCOVER1

RUN
WIRE RANGE
AL9CU

TAP
WIRE RANGE
AL9CU

AMPERE
RATING PER
POLE

BDC-14-2/0-1

2/0 - 14

4 - 14

195

BDBCOVER3

BDA-14-2/0-1

2/0 - 14

4 - 14

195

ADDER

BDBCOVER3

BDC-11-2/0-1

2/0 - 14

2/0 - 14

195

BDBCOVER3

BDA-11-2/0-1

2/0 - 14

2/0 - 14

195

ADDER

BDBCOVER3

CATALOG
NUMBER

CONNECTOR
RUN
TAP

OPTIONAL
NUMBER OF COVER ORDER
POLES
1 PER POLE

SNAP TOGETHER
SPLICER/REDUCER
BLOCKS
CATALOG
NUMBER

CONNECTOR
RUN
TAP

OPTIONAL
NUMBER OF COVER ORDER
POLES
1 PER POLE

BURNDY
Mechanical
VERSI-POLE
(Continued)
A-47

VERSI-POLE 1, 2, 3
SPLICE/REDUCER BLOCKS
These tables and illustrations refer to VERSIPOLE Power Distribution Blocks listed on
pages A-48 through A-50.

THE FIGURE TO THE LOWER RIGHT IS APPLICABLE TO THE FOLLOWING:


Catalog Number

Number of Poles

Catalog Number

Number of Poles

BDA-11-500

1 (adder)

BDB-16-500-3

BDA-112-350

1 (adder)

BDB-212-500-1

BDA-16-350

1 (adder)

BDB-212-500-2

BDA-16-500

1 (adder)

BDB-212-500-3

BDA-212-500

1 (adder)

BDB-22-350-1

BDA-22-350

1 (adder)

BDB-22-350-2

BDA-22-500

1 (adder)

BDB-22-350-3

BDA-24-500

1 (adder)

BDB-22-500-1

BDA-26-350

1 (adder)

BDB-22-500-2

BDA-26-500

1 (adder)

BDB-22-500-3

BDB-11-500-1

BDB-24-500-1

BDB-11-500-2

BDB-24-500-2

BDB-11-500-3

BDB-24-500-3

BDB-112-350-1

BDB-26-350-1

BDB-112-350-2

BDB-26-350-2

BDB-112-350-3

BDB-26-350-3

BDB-16-350-1

BDB-26-500-1

BDB-16-350-2

BDB-26-500-2

BDB-16-350-3

BDB-26-500-3

BDB-16-500-1

BDB-430-500-1

BDB-16-500-2

NO. OF
POLES

DIMENSIONS A
INCHES

Adder
1
2
3
N

2.50
2.81
5.31
7.81
(2.50 X N) + .31

Example for 10 poles:


A = (2.50 X 10) + .31 = 25

BURNDY
Mechanical
VERSI-POLE
(Continued)
A-48

VERSI-POLE 1, 2, 3
SPLICE/REDUCER BLOCKS
These tables and illustrations refer to VERSIPOLE Power Distribution Blocks listed on
pages A-48 through A-50.
THE FIGURE TO THE RIGHT IS
APPLICABLE TO THE FOLLOWING:
Catalog Number

Number of Poles

BDB-11-2/0-1

BDB-11-2/0-2

BDB-11-2/0-3

BDB-11-350-1

BDB-11-350-2

BDB-11-350-3

BDB-14-500-1

BDB-14-500-2

BDB-14-500-3

BDB-16-2/0-1

BDB-16-2/0-2

BDB-16-2/0-3

BDB-162-500-1

BDB-162-500-2

BDB-162-500-3

BDB-22-2/0-1

BDB-22-2/0-2

BDB-22-2/0-3

BDB-26-2/0-1

BDB-26-2/0-2

BDB-26-2/0-3

APPLICABLE VERSI-POLETM ITEMS


Catalog Number

Number of Poles

BDA-14-2/0-1

1 (adder)

BDC-14-2/0-1

BDA-11-2/0-1

1 (adder)

BDC-11-2/0-1

NO. OF
POLES

DIMENSIONS A
INCHES

Adder
1
2
3
N

.81
1.08
1.89
2.70
(.81 X N) + .27

Example for 10 poles:


A = (.81 X 10) + .27 = 8.37

NO. OF
POLES

DIMENSIONS A
INCHES

Adder
1
2
3
N

1.64
1.94
3.57
5.20
(1.64 X N) + .30

Example for 10 poles:


A = (1.64 X 10) + .30 = 16.20

BURNDY
Mechanical
BURNDY UNITAP
CLEAR INSULATED
MULTIPLE TAP CONNECTORS

A-49

Tap connections and in-line splice/reductions


are made quickly and easily with the
UNITAP line of connectors. UL486B Listed.
Dual-rated AL9CU for any stranded copper or
stranded aluminum applications. 600 Volt,
90 C.

Features and Benefits


Clear Plastisol covered AL6061-T6
aluminum body.
Saves time, lowers installation costs,
eliminates taping.
Clear Plastisol.
Allows visual confirmation that
conductor is properly inserted.

Oxide inhibitor pre-installed.


Inhibits moisture and contaminants
from entering the contact area.
Range-taking.
Reduces number of connectors carried
in inventory.

2 PORT 1 or 2 Sided Entry


Catalog
Number

# of
Ports

Wire Range
(AWG/kcmil)

Hex Key

Fig.
No.

BIT4
BITO4
BIT2/0
BITO2/0
BIT250
BITO250
BIT350
BITO350
BIT600
BITO600
BIT750*
BITO750*

2
2
2
2
2
2
2
2
2
2
2
2

#14 - #4
#14 - #4
#14 - 2/0
#14 - 2/0
#10 - 250
#10 - 250
#10 - 350
#10 - 350
#4 - 600
#4 - 600
#2 - 750
#2 - 750

1.16
1.16
1.52
1.52
2.03
2.03
2.22
2.22
2.72
2.72
2.87
2.87

1.16
1.50
1.40
1.56
2.07
2.64
2.32
3.00
2.38
3.00
2.70
3.38

1.25
1.25
1.38
1.38
2.13
2.13
2.50
2.50
2.75
2.75
3.00
3.00

1/8
1/8
3/16
3/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8

1
2
1
2
1
2
1
2
1
2
1
2

Fig. 1

* Not UL Listed

Fig. 2

IN-LINE SPLICER/REDUCER
Catalog
Number

Wire Range
(AWG/kcmil)

Hex Key

BISR2
BISR1/0
BISR250
BISR350
BISR500

#14 - 2
#14 - 1/0
#10 - 250
#10 - 350
#6 - 500

2.38
2.91
4.01
4.63
5.00

0.75
0.91
1.19
1.34
1.62

1.22
1.38
2.10
2.35
2.62

5/32
3/16
5/16
5/16
3/8

BURNDY
Mechanical
BURNDY UNITAP
A-50

MULTI-PORT
Single-Sided Entry
Catalog
Number
BIBS4-3
BIBS4-4
BIBS4-5
BIBS4-6
BIBS4-8
BIBS2/0-3
BIBS2/0-4
BIBS2/0-5
BIBS2/0-6
BIBS2/0-8
BIBS2/0-10
BIBS2/0-12
BIBS2/0-14
BIBS250-3
BIBS250-4
BIBS250-5
BIBS250-6
BIBS250-8
BIBS250-10
BIBS250-12
BIBS250-14
BIBS350-3

# of Wire Range
Ports (AWG/kcmil)
3
4
5
6
8
3
4
5
6
8
10
12
14
3
4
5
6
8
10
12
14
3

#14 - 4
#14 - 4
#14 - 4
#14 - 4
#14 - 4
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 350

Hex
Key

Catalog
Number

1.59
2.03
2.47
2.91
3.78
2.19
2.86
3.53
4.20
5.55
6.89
8.24
9.58
2.97
3.91
4.84
5.78
7.66
9.53
11.41
13.29
3.13

1.25
1.25
1.25
1.25
1.25
1.31
1.31
1.31
1.31
1.31
1.31
1.31
1.31
2.07
2.07
2.07
2..07
2.07
2.07
2.07
2.07
2.32

1.25
1.25
1.25
1.25
1.25
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
2.13
2.13
2.13
2.13
2.13
2.13
2.13
2.13
2.50

1/8
1/8
1/8
1/8
1/8
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16

BIBS350-4
BIBS350-5
BIBS350-6
BIBS350-8
BIBS350-10
BIBS350-12
BIBS350-14
BIBS600-3
BIBS600-4
BIBS600-5
BIBS600-6
BIBS600-8
BIBS600-10
BIBS600-12
BIBS600-14
BIBS750-3*
BIBS750-4*
BIBS750-6*
BIBS750-8*
BIBS750-10*
BIBS750-12*
BIBS750-14*
* Not UL Listed

# of Wire Range
Ports (AWG/kcmil)
4
5
6
8
10
12
14
3
4
5
6
8
10
12
14
3
4
6
8
10
12
14

#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750

Hex
Key

4.04
4.95
5.86
7.68
9.50
11.32
13.14
4.00
5.28
6.56
7.84
10.41
12.97
15.53
18.09
4.25
5.63
8.37
11.13
13.87
16.63
19.37

2.32
2.32
2.32
2.32
2.32
2.32
2.32
2.38
2.38
2.38
2.38
2.38
2.38
2.38
2.38
2.70
2.70
2.70
2.70
2.70
2.70
2.70

2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75
3.00
3.00
3.00
3.00
3.00
3.00
3.00

5/16
5/16
5/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8

BURNDY
Mechanical
BURNDY UNITAP
A-51

MULTI-PORT
Double-Sided Entry
Catalog
Number
BIBD4-2
BIBD4-3
BIBD4-4
BIBD4-5
BIBD4-6
BIBD4-8
BIBD2/0-2
BIBD2/0-3
BIBD2/0-4
BIBD2/0-5
BIBD2/0-6
BIBD2/0-8
BIBD2/0-10
BIBD2/0-12
BIBD2/0-14
BIBD250-2
BIBD250-3
BIBD250-4
BIBD250-5
BIBD250-6
BIBD250-8
BIBD250-10
BIBD250-12
BIBD250-14
BIBD350-2

# of Wire Range
Ports (AWG/kcmil)
2
3
4
5
6
8
2
3
4
5
6
8
10
12
14
2
3
4
5
6
8
10
12
14
2

#14 - #4
#14 - #4
#14 - #4
#14 - #4
#14 - #4
#14 - #4
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 350

Hex
Key

Catalog
Number

1.16
1.59
2.03
2.47
2.91
3.78
1.52
2.19
2.86
3.53
4.20
5.55
6.89
8.24
9.58
2.03
2.97
3.91
4.84
5.78
7.66
9.53
11.41
13.29
2.22

1.50
1.50
1.50
1.50
1.50
1.50
1.56
1.56
1.56
1.56
1.56
1.56
1.56
1.56
1.56
2.64
2.64
2.64
2.64
2.64
2.64
2.64
2.64
2.64
3.00

1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
2.13
2.13
2.13
2.13
2.13
2.13
2.13
2.13
2.13
2.50

1/8
1/8
1/8
1/8
1/8
1/8
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16

BIBD350-3
BIBD350-4
BIBD350-5
BIBD350-6
BIBD350-8
BIBD350-10
BIBD350-12
BIBD350-14
BIBD600-2
BIBD600-3
BIBD600-4
BIBD600-5
BIBD600-6
BIBD600-8
BIBD600-10
BIBD600-12
BIBD600-14
BIBD750-2*
BIBD750-3*
BIBD750-4*
BIBD750-6*
BIBD750-8*
BIBD750-10*
BIBD750-12*
BIBD750-14*

# of Wire Range
Ports (AWG/kcmil)
3
4
5
6
8
10
12
14
2
3
4
5
6
8
10
12
14
2
3
4
6
8
10
12
14

#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750
#2 - 750

NOTE: Only 1 conductor per port allowed.


* Not UL Listed

Hex
Key

3.13
4.04
4.95
5.86
7.68
9.50
11.32
13.14
2.56
3.77
4.97
6.17
7.37
9.78
12.97
15.53
18.09
2.87
4.25
5.63
8.37
11.13
13.87
16.63
19.37

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.38
3.38
3.38
3.38
3.38
3.38
3.38
3.38

2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75
2.75
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00

5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8

BURNDY
Mechanical
BURNDY UNITAP
A-52

CLEAR INSULATED
MULTIPLE TAP CONNECTORS
MOUNTING VERSION
TYPE BIBS-MT, BIBD-MT
The BIBS-MT and BIBD-MT series UNITAP
offer the same multi-port capabilities as the
standard UNITAP connectors except these
-MT types are provided with two isolated
mounting holes at both ends of the connector
for direct mounting to a trough, gutter or
wireway. They will accommodate up to
standard 1/4 hardware.

Fig. 2

Fig. 1

MULTI-PORT
Single-Sided Entry
Catalog
Number
BIBS2/04MT
BIBS2/06MT
BIBS2/08MT
BIBS2/010MT
BIBS2/012MT
BIBS2504MT
BIBS2506MT
BIBS2508MT
BIBS25010MT
BIBS25012MT
BIBS3504MT
BIBS3506MT
BIBS3508MT
BIBS35010MT
BIBS35012MT
BIBS6004MT
BIBS6006MT
BIBS6008MT
BIBS60010MT
BIBS60012MT

# of
Fig # Ports
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

4
6
8
10
12
4
6
8
10
12
4
6
8
10
12
4
6
8
10
12

MULTI-PORT
Double-Sided Entry
Wire Range
(AWG/Kcmil)

Hex
Key

Catalog
Number

#14-2/0
#14-2/0
#14-2/0
#14-2/0
#14-2/0
#10-250
#10-250
#10-250
#10-250
#10-250
#10-350
#10-350
#10-350
#10-350
#10-350
#4-600
#4-600
#4-600
#4-600
#4-600

3.95
5.29
6.64
7.98
9.33
5.53
7.40
9.28
11.16
13.03
5.61
7.43
9.25
11.07
12.89
7.59
10.16
12.72
15.28
17.84

1.31
1.31
1.31
1.31
1.31
2.07
2.07
2.07
2.07
2.07
2.32
2.32
2.32
2.32
2.32
2.38
2.38
2.38
2.38
2.38

1.38
1.38
1.38
1.38
1.38
2.13
2.13
2.13
2.13
2.13
2.50
2.50
2.50
2.50
2.50
2.75
2.75
2.75
2.75
2.75

3/16
3/16
3/16
3/16
3/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8
3/8

BIBD2/04MT
BIBD2/06MT
BIBD2/08MT
BIBD2/010MT
BIBD2/012MT
BIBD2504MT
BIBD2506MT
BIBD2508MT
BIBD25010MT
BIBD25012MT
BIBD3504MT
BIBD3506MT
BIBD3508MT
BIBD35010MT
BIBD35012MT
BIBD6004MT
BIBD6006MT
BIBD6008MT
BIBD60010MT
BIBD60012MT

# of
Fig # Ports
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

4
6
8
10
12
4
6
8
10
12
4
6
8
10
12
4
6
8
10
12

Wire Range
(AWG/Kcmil)

Hex
Key

#14-2/0
#14-2/0
#14-2/0
#14-2/0
#14-2/0
#10-250
#10-250
#10-250
#10-250
#10-250
#10-350
#10-350
#10-350
#10-350
#10-350
#4-600
#4-600
#4-600
#4-600
#4-600

3.95
5.29
6.64
7.98
9.33
5.53
7.40
9.28
11.16
13.03
5.61
7.43
9.25
11.07
12.89
7.59
10.16
12.72
15.28
17.84

1.56
1.56
1.56
1.56
1.56
2.64
2.64
2.64
2.64
2.64
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00

1.38
1.38
1.38
1.38
1.38
2.13
2.13
2.13
2.13
2.13
2.50
2.50
2.50
2.50
2.50
2.75
2.75
2.75
2.75
2.75

3/16
3/16
3/16
3/16
3/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8
3/8

BURNDY
Mechanical
BURNDY UNITAP
THE MOLE
A-53

For Direct Burial


600V, 90C
Designed specifically for direct burial applications, the MOLE inline splice/reducer is
made with a specialized plastisol material
that forms a rugged weathertight connection.

Features and Benefits


UL486D Listed for direct burial.
AL9CU Dual-rated for copper and
aluminum applications. 600V 90C.
Plastisol covered AL6061-T6 aluminum
body saves time by eliminating the need
for heat shrink.
Oxide inhibitor pre-installed preventing
moisture and contaminants from entering
contact area.
Range-taking capability reduces the
number of connectors carried in inventory.

Number
of
Ports

Wire
Range
(AWG/kcmil)

BISR4-DB

#6 - 4 AWG

4.30

0.80

1.28

BISR1-DB

#2 - 1 AWG

6.30

0.93

1.59

BISR3/0-DB

1/0 - 3/0 AWG

6.25

0.99

1.84

BISR250-DB

4/0 - 250 kcmil

6.70

1.18

2.03

Catalog
Number

BISR-DB = BURNDY Inline Splice/Reducer Direct Burial

Dimensions (Inches)
L
W
H

Hex Key
(Torque)
(In.-lbs.)
1/8
(50)
5/32
(130)
3/16
(220)
5/16
(360)

Wire
Strip
Length
7/8
1-3/32
1-3/32
1-5/16

BURNDY
Mechanical
UV RATED
BLACK UNITAP
A-54

For Direct Burial


600V, 90C

Features and Benefits


UV Rated Plastisol covered AL6061-T6
aluminum body saves time by eliminating
the need for taping.
Oxide inhibitor pre-installed inhibits
moisture and contaminants from
entering the contact area.

Catalog
Number
1PL42
1PLO42
1PL2/02
1PLO2/02
1PL2502
1PLO2502
1PL3502
1PL6002
1PLO6002
1PBS2
1PBS1/0
1PBS250
1PBS350
1PBS500
1PL43
1PL44
1PL2/03
1PL2503
1PLD43
1PLD44
1PLD2/02
1PLD2/03
1PLD2/04
1PLD2/06
1PLD2502
1PLD2503
1PLD2504
1PLD2506
1PLD3502
1PLD3503
1PLD3504
1PLD3506
1PLD3508
1PLD6002
1PLD6003
1PLD6004
1PLD6005
1PLD6006
1PLD6008

Fig.
No.

Number
of
Ports

Wire
Range
(AWG/kcmil)

3
4
3
4
3
4
3
3
4
1
1
1
1
1
5
5
5
5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
4
3
3
3
4
2
3
4
6
2
3
4
6
2
3
4
6
8
2
3
4
5
6
8

#14 - 4
#14 - 4
#14 - 2/0
#14 - 2/0
#10 - 250
#10 - 250
#10 - 350
#4 - 600
#4 - 600
#14 - 2
#14 - 1/0
#10 - 250
#10 - 350
#6 - 500
#14 - 4
#14 - 4
#14 - 2/0
#10 - 250
#14 - 4
#14 - 4
#14 - 2/0
#14 - 2/0
#14 - 2/0
#14 - 2/0
#10 - 250
#10 - 250
#10 - 250
#10 - 250
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#10 - 350
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600
#4 - 600

1PL = 2 Port Single Sided Entry


1PLO = 2 Port Offset Entry
1PBS = In-line Splice/Reducer

Dimensions (Inches)
W

1.16
1.16
1.52
1.52
2.03
2.03
2.22
2.72
2.72
2.38
2.91
4.01
4.63
5.00
1.59
2.03
2.19
2.97
1.59
2.03
1.52
2.19
2.86
4.20
2.03
2.97
3.91
5.78
2.22
3.13
4.04
5.86
7.68
2.56
3.77
4.97
6.17
7.37
9.78

1.16
1.50
1.40
1.56
2.07
2.64
2.32
2.38
3.00
0.75
0.91
1.19
1.34
1.62
1.25
1.25
1.31
2.07
1.50
1.50
1.56
1.56
1.56
1.56
2.64
2.64
2.64
2.64
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00

1PL = Multi-Port Single Sided Entry


1PLD = Multi-Port Double Sided Entry

Range-taking capability reduces the


number of connectors carried in inventory.
UL486B Listed, AL9CU, 600V 90C

Hex Key
(Torque)
(In.-lbs.)

Wire
Strip
Length

1.25
1.25
1.38
1.38
2.13
2.13
2.50
2.75
2.75
1.22
1.38
2.10
2.35
2.62
1.25
1.25
1.38
2.13
1.25
1.25
1.25
1.25
1.25
1.25
2.13
2.13
2.13
2.13
2.50
2.50
2.50
2.50
2.50
2.75
2.75
2.75
2.75
2.75
2.75

1/8 (45)
1/8 (45)
3/16 (120)
3/16 (120)
5/16 (275)
5/16 (275)
5/16 (275)
3/8 (375)
3/8 (375)
5/32 (45)
3/16 (120)
5/16 (120)
5/16 (275)
3/8 (375)
1/8 (45)
1/8 (45)
3/16 (120)
5/16 (275)
1/8 (45)
1/8 (45)
3/16 (120)
3/16 (120)
3/16 (120)
3/16 (120)
5/16 (275)
5/16 (275)
5/16 (275)
5/16 (275)
5/16 (375)
5/16 (375)
5/16 (375)
5/16 (375)
5/16 (375)
3/8 (375)
3/8 (375)
3/8 (375)
3/8 (375)
3/8 (375)
3/8 (375)

5/8
5/8
11/16
11/16
1
1
1-1/8
1-1/8
1-1/8
3/4
1
1-3/16
1-3/8
1-1/2
5/8
5/8
11/16
1
5/8
5/8
11/16
11/16
11/16
11/16
1
1
1
1
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8

BURNDY
Mechanical
TYPE KSA
TRITAP SERVIT
For All Combinations of
Aluminum to Aluminum,
Aluminum to Copper and
Copper to Copper, Aluminum
Alloy Tin Plated
PATENTED TRIANGULAR
PENETRATION TECHNOLOGY
CONTACT

Features and Benefits

CATALOG CROSS
NUMBER FLATS L

No scratch brushing required.


No oxide inhibitor required.
Orients the conductor.
Provides maximum pressure and assures
a secure connection of run and tap
conductors.
Facilitates piercing the aluminum
conductor surface oxides.
UL 486B listed, 90C rated.
Provides a low contact resistance.
Provides equal coefficient of expansion
Inhibits the reformation of oxides by
producing a gas-tight seal.
Provides improved retention of minimum
to maximum conductor combinations.

ALUM. TO ALUM., ALUM. TO COPPER, COPPER TO COPPER CONDUCTORS


MAX. RUN TO MAX. TAP
MIN. RUN TO MIN. TAP
MAX. RUN TO MIN. TAP

KSA6
KSA4
KSA2

.75
.81
.94

1.28 .56
1.38 .62
1.58 .69

#6 STR. (.184)
#4 STR. (.232)
#2 STR. (.292)

#6 STR. (.184)
#4 STR. (.232)
#2 STR. (.292)

KSA 1/0

1.00

1.92 .75

#1/0 STR. (.373)

#1/0 STR. (.373)

KSA 2/0

1.12

1.92 .88

#2/0 STR. (.418)

#2/0 STR. (.418)

KSA 4/0

1.49

2.54 1.13 #4/0 STR. (.528)

#4/0 STR. (.528)

*KSA 350

1.69

3.24 1.50 350 KCMIL (.681) 350 KCMIL (.681)

*KSA 500

2.00

3.62 1.73 500 KCMIL (.813) 500 KCMIL (.813)

Listed torque values are for maximum conductor


combinations accommodated. Consult UL486 Tables 7-4,
7-5, 7-6 for smaller conductor combinations.
* Not CSA listed.
** No scratch brushing or oxide inhibiting compounds
required for insulated 90 C max. rated conductor for
N.E.C. applications.

#10 SOL. (.102)


#10 SOL. (.102)
#8 SOL. (.129)
#10 SOL. (.102)
#6 SOL. (.169)
#8 STR. (.146)
#2 STR. COMPACT
#8 SOL. (.129)
(.268)
#2 STR. COMPACT
#8 STR. (.146)
(.268)
#2 STR. COMPACT
#6 STR. (.184)
(.268)
#1/0 STR. COMPACT
#4 STR. (.232)
(.336)
400 KCMIL
#2 STR. COMPACT
COMPACT (.659)
(.268)

RECOMMENDED
TIGHTENING
TORQUE in-lb

#6 STR. (.184)
#4 STR. (.232)
#2 STR. (.292)

#10 SOL. (.102)


#10 SOL. (.102)
#8 SOL. (.146)

165
165
275

#1/0 STR. (.373)

#8 SOL. (.129)

385

#2/0 STR. (.418)

#8 STR. (.146)

385

#4/0 STR. (.528)

#6 STR. (.184)

500

#350 KCMIL (.681)

#4 STR. (.232)

650

#500 KCMIL (.813)

#2 STR. COMPACT
(.268)

825

BURNDY
Mechanical
TYPE KVS
OKLIP
Mechanical Connector
For Copper & Copperweld
Compact, two-piece, high strength, high
copper alloy BURNDY OKLIP recommended for heavy duty connections. Neoprene
rings hold DURIUM bolts in place during
installation. Installed with ordinary wrench.

CONDUCTOR
COPPER
RUN

TAP

SOL.

COPPERWELD
MAX. RUN AND TAP
STR.

2 STR. - 2/0 STR.


1/0 STR. - 4/0 STR.
250 - 350
400 - 500
400 - 800
500 - 1000

6 SOL. - 2/0 STR.


10 STR. - 4/0 STR.
10 STR. - 350
10 STR. - 500
3/0 STR - 800
3/0 STR. - 1000

3/0
4/0

7 #8
7 #6
19 #8
19 #6
19 #5

CATALOG
NUMBER
KVS26
KVS28
KVS31
KVS34
KVS40
KVS44

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5,
7-6 for smaller conductor combinations.

TYPE V

RECOMMENDED
TIGHTENING
TORQUE in-lb

V3/0
V250
V350

180
250
325
375
500
500

See note page A-2

TYPE KVSU
UNIVERSAL OKLIP
Mechanical Connector
For All Combinations
of Copper, Aluminum,
ACSR, AAAC & 5005
Compact, high strength, tin plated copper
alloy two-piece connector with spacer and tinplated silicon bronze DURIUM hardware.
Recommended for heavy duty connections.
Spacer separates dissimilar conductors and

provides long contact length. Neoprene ring


prevents loss of shorter bolt during installation. Longer peened bolt permits swivel action
for easier installation.

Use of PENETROX joint compound recommended with aluminum and ACSR.

CONDUCTOR
RUN

CATALOG
NUMBER COPPER & ALUM.
KVSU26
KVSU28
KVSU31
KVSU34
KVSU40
KVSU44

TAP

ACSR,
AAAC,
& 5005

2 STR. - 2/0 STR.


3 - 2/0
1/0 STR. - 4/0 STR.
1/0 - 4/0
250 - 350
4/0 - 300
400 - 500
336.4 - 397.5
400 - 800
4/0 - 800
500 - 1000
4/0 - 1000

RUN
TAP
COPPER
COPPER
ACSR,
SOL.,
SOL.,
AAAC, COPPERWELD STEEL COPPERWELD STEEL
COPPER & ALUM. & 5005
SOL.,
NOM. DIA.
SOL.,
NOM. DIA. H
6 STR. - 2/0 STR.
6 STR. - 4/0 STR.
6 - 350
4 - 500
4/0 - 800
4/0 - 1000

Accomodations compressed conductors within diameter


range.
See note page A-2

6 - 2/0
6 - 4/0
6 - 300
5 - 397.5
3/0 - 715.5
4/0 - 900

1 - 3/0
2/0 - 4/0

5/16 - 7/16
3/8 - 1/2
9/16 - 5/8
3/4 - 3/4
3/4 - 1
7/8 - 1-1/8

#6 - 3/0
#6 - 4/0
#6 - 4/0
#4 - 4/0

3/16 - 7/16 2 5/16 1 1-1/2


5/32 - 1/2 2-3/8 3/8 1-1/8 1-3/4
3/16 - 5/8 2-5/8 1/2 1-3/8 2-1/8
7/32 - 3/4
3
1/2 1-1/2 2-1/4
1/2 - 1 3-1/2 1/2 1-5/8 2-1/2
1/2 - 1-1/8 4
3/8
2
3

RECOMMENDED
TIGHTENING
TORQUE in-lb
180
250
325
375
500

BURNDY
Mechanical
TYPE KVSW
OKLIP
Mechanical Connector
For Copper and Copperweld.
Similiar to OKLIP Type KVS except for a
high copper alloy spacer that separates run
and tap conductors. Provides high contact
pressure, confines conductor strands, and
assures vibration-proof connection. Longer
peened bolt, permits swivel action for easier
installation. Silicon bronze DURIUM hardware.

CATALOG
NUMBER

RECOMMENDED
TIGHTENING
TORQUE in-lb

CONDUCTOR
RUN

KVSW26
KVSW28
KVSW31
KVSW34
KVSW40
KVSW44

TAP

2 STR. - 2/0 STR.


1/0 STR. - 4/0 STR.
250 - 350
400 - 500
400 - 800
500 - 1000

6 SOL. - 2/0 STR.


6 SOL. - 4/0 STR.
4 SOL. - 350
4 STR. - 500
4/0 - 800
250 - 1000

180
250
325
375
500
500

See note page A-2

TYPE KVS-A
ALUMINUM OKLIP
Mechanical Connector
For All Combinations of
Copper, Aluminum, ACSR,
AAAC and 5005
Three-piece, high-conductivity, non-copper
bearing aluminum alloy connector with thick
spacer and aluminum hardware. Hardware in
KVS26A and KVS28A is stainless steel.
Recommended for heavy duty dissimilar
metal applications. Spacer separates conductors and provides long contact length. Belled
entrances prevent chafing, permit easier
assembly of conductors. Longer peened bolt
permits swivel action for easier installation.
Neoprene ring prevents loss of shorter bolt.
PENETROX joint compound recommended with aluminum and ACSR.

THESE CONNECTORS
CAN ACCOMMODATE
ACSR CONDUCTORS
OVER ARMOR ROD WITHIN
THE DIAMETER RANGE
INDICATED.
APPLICATION OVER
ARMOR ROD

CONDUCTOR
RUN
CATALOG
NUMBER
KVS26A
KVS28A
KVS31A
KVS34A
KVS40A
KVS44A

COPPER,
& ALUM.

ACSR,
AAAC, & 5005

COPPER,
& ALUM.

TAP
ACSR,
AAAC & 5005

RECOMMENDED
TIGHTENING
TORQUE in-lb

2 STR. - 2/0 STR.


1/0 STR. - 4/0 STR.
250 - 350
400 - 500
400 - 800
500 - 1000

4 - 2/0
1/0 - 4/0
4/0 - 336.4
336.4 - 397.5
336.4 - 715.5
397.5 - 900

10 STR. - 2/0 STR.


10 STR. - 4/0 STR.
6 STR. - 350
4 STR. - 500
3/0 STR. - 800
3/0 STR. - 1000

6 - 2/0
6 - 4/0
6 - 336.4
5 - 397.5
3/0 - 715.5
3/0 - 900

180
240
300
300
300
480

Accommodates compressed conductors within diameter


range.
See note page A-2

CONDUCTOR RANGE BY DIAMETER


CATALOG
MAX. RUN &
NUMBER MIN. RUN DIA. MIN. TAP DIA.
TAP DIA.
KVS26A
KVS28A
KVS31A
KVS34A
KVS40A
KVS44A

.281
.360
.565
.728
.728
.806

.116
.116
.184
.216
.470
.470

.447
.564
.681
.814
1.036
1.162

2-1/4
3
3-1/16
3-9/16
4-1/16
4-7/8

5/16
3/8
1/2
1/2
1/2
5/8

1-1/4
1-5/8
1-15/16
2-5/16
2-7/16
2-1/2

1-5/8
2-1/16
2-7/16
2-5/8
2-7/8
3-1/8

You might also like