DYNAMOMETER ANALYSIS

SAMPLE COMPANY SAMPLE et al SASKATCHEWAN 1-2-3-14 100/01-02-003-14W2/0 FIELD: PROLIFIC FORMATION: GOODSAND TEST DATE: November 20, 2008
(Analysis Provided by NR-Tec Ltd.)

DISTRIBUTION: PREPARED BY: DATE:

BOB LOBLAW NR-Tec Analyst November 21, 2008

TEST DATE: November 20, 2008

100/01-02-003-14W2/0

DYNALOG GRAPHIC SUMMARY


120
107 103 95 69 72 49 E I E I E I 49 E I E I 95 86 86

PERCENT

100 80 60 40 20 0 GEARBOX PRIME MOVER

STRUCTURAL ROD STRING

OVERALL PUMP EFF.

EXISTING

INBALANCE

100 PERCENT

PRODUCTION POTENTIAL The results of the pumping fluid level test indicate approximately 337 meters of pump submergence. A pump intake pressure of 2828 kPa was determined from these results using an estimated annular fluid gradient of 6.000 kPa/m. Based on these results additional production may be available from the well. GENERAL COMMENTS The pump card indicates very good efficiency with slight losses due to tubing movement (tubing is unanchored). The valve checks indicate that the bottomhole pump is in excellent mechanical condition with only a slight amount of travelling valve leakage and/or plunger slippage. RECOMMENDATIONS If a more accurate calculation of the pump intake pressure is desired to determine the amount of available productivity, an annular fluid depression test and inflow performance relationship study should be conducted. If the existing gearbox torque (107% of rating) cannot be tolerated, a reduction in pumping speed of approximately 0.5 SPM would be required. A complete system re-design should be considered to maintain or increase production levels without experiencing any equipment overload. When the well is next serviced, consider installing a tension type tubing anchor to eliminate efficiency losses and equipment wear due to tubing movement and extend the life of the equipment. Counterbalance requirements should be re-evaluated following any changes to equipment or operation.

SAMPLE et al SASKATCHEWAN 1-2-3-14

TEST DATE: November 20, 2008

100/01-02-003-14W2/0

PAGE 1

PUMP UNIT
LUFKIN ROTATION PITMAN POSITION PUMPING SPEED (SPM) STROKE LENGTH (cm) / (in) BALANCE CONDITION CONVENTIONAL 228-213-100 CW 1 OF 4 10.3 254 / 100 UNDER EXISTING ELECTRIC 22.86 30 / 25 / 20 37 / 31 / 25 1125 EXISTING POLISHED ROD H.P. CYCLIC LOAD FACTOR APPROX. MOTOR H.P. 11.79 1.498 20.8 INBALANCE 11.79 1.555 21.6 C.B. EFFECT (lb) C.B. MOMENT (in-lb) 7163 346448 7469 361206 MIN. TORQUE (in-lb) - % OF RATING MAX. LOAD (lb) - % OF RATING -56364 25 10505 49 -68190 30 10505 49 MAX. TORQUE (in-lb) - % OF RATING 243543 107 INBALANCE 234204 103

PRIME MOVER
BALDOR SHEAVE O.D. (cm) RATED HORSEPOWER RATED AMPS (RMS) RATED RPM

PUMP EFFICIENCY
TOTAL PLUNGER STROKE (cm) PUMP DISPLACEMENT (m3/d) FLUID PROD'N AS % OF TOTAL DISP. OIL PRODUCTION RATE (m3/d) WATER PRODUCTION RATE (m3/d) TOTAL FLUID PROD. RATE (m3/d) GAS - OIL RATIO EFFECTIVE PLUNGER STROKE (cm) EFFECTIVE PUMP DISPLACEMENT (m3/d) FLUID PROD. AS % OF EFF. PUMP DISP. PRODUCTION TEST DATE 240 72.6 86 1.65 60.85 62.50 152 229 69.3 90 2008-11

FLUID LEVEL AND PRESSURES


TUBING PRESSURE (kPa) CASING PRESSURE (kPa) PUMPING FLUID LEVEL (mCF) PUMP SUBMERGENCE (m) * ANNULAR FLUID GRADIENT (kPa/m) PRESS. DUE TO GAS COLUMN (kPa) PRESS. DUE TO FLUID COLUMN (kPa) PUMP INTAKE PRESSURE (kPa) * ESTIMATED CASING TIED-IN AND OPEN TO FLOWLINE 802 762 600.03 337.17 6.000 43 2023 2828

ROD LOADING
DIAM. SECTION POL. ROD 2 3 (mm) 31.75 19.05 19.05 LOAD (lb) MAX. 10505 10505 7527 MIN. 1870 1870 634 STRESS (psi) MAX. 8561 23779 17037 MIN. 1523 4232 1434 32 73 55 PERCENT API GOODMAN 1.0 S.F. 0.8 S.F. 41 95 70 0.6 S.F. 56 135 96 ROD GRADE C D D

SAMPLE et al SASKATCHEWAN 1-2-3-14

TEST DATE: November 20, 2008

100/01-02-003-14W2/0 SUMMARY OF BASIC WELL INFORMATION 1. PUMP UNIT


LUFKIN CONVENTIONAL

PAGE 2

228-213-100 254 / 100

STROKE LENGTH (cm) / (in) SHEAVE O.D.: 28.0 inches BELT SIZE: 3 type C285 COUNTER WEIGHTS LEAD A LAG A LEAD B LAG B 3CR0 ELECTRIC 3CR0 AUXILIARY WEIGHTS

GEARBOX RATIO: 34.557:1 CRANK #: 7478B WEIGHT POSITION 3.0"

3.0"

2. PRIME MOVER
BALDOR SHEAVE O.D. (cm) RATED HORSEPOWER RATED AMPS (RMS) RATED RPM VOLT RATING 22.86 30 / 25 / 20 37 / 31 / 25 1125 460

NOTES:

3. ELEVATIONS
KB ELEVATION (m) CF ELEVATION (m) 698.51 694.71 3.80 73.03 952.13 99.0 / 9.579

Rod rotator installed and functioning properly. Belts are tight and in good condition. The brake is in good mechanical condition. A visual inspection of the polished rod indicates it is in good condition. Well is equipped with rod pump controller. Runtime - 100 %

KB - CF (m)

5. TUBING
DIAMETER (mm) SET AT (mKB) NO. OF JTS. / AVG. JT. LENGTH (m)

6. CASING
DIAMETER (mm) SET AT (mKB) 139.70 999.00

7. BOTTOMHOLE PUMP
63.5 X 50.8 X RWAC X 4.9 X 0.9 PLUNGER DIAMETER (in) / (mm) BARREL LENGTH (ft) / (m) SETTING DEPTH (mKB) 2.00 16.00 / / 50.80 4.88 941.00

COMPLETION DETAILS
8. PRODUCING INTERVAL (mKB) TOP / BOTTOM MID-POINT 9. 10. 11. PLUG-BACK DEPTH (mKB) TOTAL DEPTH (mKB) 932.00 / 933.00 932.50 968.00 999.00

ROD STRING
DIAMETER SECTION POL. ROD 2 3 (mm) 31.75 19.05 19.05 LENGTH (m) 7.82 387.80 548.64 UNIT WT. (lb/m) 13.93 5.35 5.35 WT. IN AIR (lb) 109 2074 2934 WT. IN FLUID (lb) 95 1831 2590 API ROD GRADE C D D TENSILE STRENGTH (psi) 90000 115000 115000 Ryton Scrapered c/w Ponies Plain COMMENTS

944.26

5117

4516

SAMPLE et al SASKATCHEWAN 1-2-3-14

TEST DATE: November 20, 2008

100/01-02-003-14W2/0

PAGE 3

SURFACE AND PUMP CARDS


20 MAXIMUM LOAD = 10505 lbs MINIMUM LOAD = 1870 lbs 16 TOTAL STROKE LENGTH = 254 cm TOTAL PLUNGER TRAVEL = 240 cm

LOAD (lbs) (Thousands)

12

PUMP VELOCITY PLOT


4
MAX VEL (cm/sec): 180.9 MIN VEL (cm/sec): -150.6

TUBING MOVEMENT ESTIMATED FLUID LOAD = 2450 lbs

EFFECTIVE PLUNGER STROKE = 229 cm -4 -20 10 40 70 100 130 160 190 220 250 280

PUMP POSITION vs PUMP VELOCITY

DISPLACEMENT (cm)

GEARBOX TORQUES
300

TORQUE (in-lbs)

200 (Thousands)

Existing Torque Inbalance Torque Gearbox Rating

100

-100 0 30 60 90 120 150 180 CRANK ANGLE (degrees) 210 240 270 300 330 360

SAMPLE et al SASKATCHEWAN 1-2-3-14

Group: MyWells

Well: 100-01-02-030-04W5M (acquired on: 11/20/08 12:11:24 )

Sensor: HT974

Group: MyWells

Well: 100-01-02-030-04W5M (acquired on: 11/20/08 12:17:11 )


Tr ave ling V alve Analys is (Load K-lbs )

Sensor: HT974

11.25 10.00 8.75 7.50

Surface Card Ove rlay

12

TV

SV

10

Load (K-lbs)

CBE
4

6.25
2

5.00 3.75 2.50


0 0 50.00 100.00 150.00 200.00 250.00 300.00 350.00

Tim e Se conds

Traveling Valve Analysis


1.25 0 Pos ition (in) 100.0

Standing Valve Analysis - * - lbf 6145 lbf - * - BBL/D Calculate Buoyant Rod Weight Measured Load SV Intake Pressure - * - lbf 4225 lbf - * - psi (g)

Calc. Buoyant Rod Weight + Fluid Load Measured Load TV Leakage

Group: MyWells

Well: 100-01-02-030-04W5M (acquired on: 11/20/08 12:22:46 )

Counte rbalance Effe ct Analys is 11.25

10.00

8.75 Load K-lbs

7.50

6.25

5.00

3.75 0

25.00

50.00

75.00 Tim e Se conds

100.00

125.00

150.00

TOTAL WELL MANAGEMENT by ECHOMETER Company

11/26/08 10:20:36

Page 1