FLASKS
The described range of flasks made of Borosilicate glass 3.3 for manipulators is our standard delivery range. On request we also supply other types according to the current standard.

Flasks, Erlenmeyer
Capacity and dimensions of these Erlenmeyer flasks with narrow neck, beaded rim and graduation correspond with ISO 1773. On request Erlenmeyer flasks with wide neck are also available. Erlenmeyer flasks are not suitable for vacuum.
Capacity (ml) 25 50 100 200 250 500 1000 2000 3000 5000 D 42 51 64 78 85 105 131 166 187 220 D1 22 22 22 34 34 34 42 50 50 50 H 72 87 105 135 142 178 223 280 310 365 Pack unit 10 10 10 10 10 10 10 10 5 4 Catalogue No. HAA HAA HAA HAA HAA HAA HAA HAA HAA HAA 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 03 04 05 06 07 08 09 10 11 12

2.2

NORMAG 2005

LABORATORY GLASSWARE
Flasks, round bottom
Capacity and bulb diameter of these flasks, round bottom with narrow neck and beaded rim correspond in bulb diameter and capacity to ISO 1773. The neck sizes can slightly differ. On request we also supply flasks, round bottom with long necks.
Capacity (ml) 50 100 250 500 1000 2000 4000 6000 10000 20000 D 51 64 85 105 131 166 207 236 275 365 D1 22 22 34 34 42 50 50 65 65 80 H 105 115 145 175 210 260 315 355 420 510 Pack unit 10 10 10 10 10 10 10 4 2 1 Catalogue No. HAA HAA HAA HAA HAA HAA HAA HAA HAA HAA 60010 60010 60010 60010 60010 60010 60010 60010 60010 60010 04 05 06 07 08 09 10 11 12 13

Flasks, flat bottom


Capacity and bulb diameter of these flasks, flat bottom with narrow neck and beaded rim correspond in bulb diameter and capacity to ISO 1773. The neck size can slightly differ. On request we also supply flasks, flat bottom with long necks. Flasks, flat bottom are not suitable for vacuum.
Capacity (ml) 50 100 250 500 1000 2000 3000 4000 10000 D 51 64 85 105 131 166 191 207 279 D1 22 22 34 34 42 50 50 50 65 H 100 110 140 170 200 250 250 300 400 Pack unit 10 10 10 10 10 10 10 5 4 Catalogue No. HAA HAA HAA HAA HAA HAA HAA HAA HAA 60020 60020 60020 60020 60020 60020 60020 60020 60020 04 05 06 07 08 09 10 11 12

NORMAG 2005

2.3

LABORATORY GLASSWARE
TEST TUBES
These test tubes are fitted with SVL-screw thread and are delivered with a screw cap and PTFE lined rubber disc. All parts are autoclaveable up to 121 C for two hours.
Capacity (ml) 8 10 15 20 20 25 30 40 50 70 D H SVL-thread Pack unit 40 40 40 40 40 40 40 40 40 40 Catalogue No. HAA HAA HAA HAA HAA HAA HAA HAA HAA HAA 60070 60070 60070 60070 60070 60070 60070 60070 60070 60070 01 02 03 04 05 06 07 08 09 10

14 16 18 16 20 18 26 20 22 26

100 100 100 160 100 180 100 200 200 200

13 15 18 15 20 18 25 20 22 25

REACTION VESSELS WITH LABORATORY FLAT FLANGE


Distillation, rectification, extraction and of course reactions are preferably made with vessels. The particular, vessel and lid are fitted with a laboratory flat flange, allowing an easy opening and closing. Suitable for 0-ring seals ensuring a safe operation under vacuum and overpressure. They are fitted with a tempering jacket through which the temperature controlling medium can circulate. Our delivery program contents a wide range of pre-fabricated parts made of Borosilicate glass 3.3 and described in catalogue part 5. Furthermore, we offer a wide range of semi-finished products for manipulators.

2.4

NORMAG 2005

LABORATORY GLASSWARE
Blanks
They are used for manufacturing of reaction vessels in short style. "DN" and "capacity" in the following table refer to the nominal size of the laboratory flat flange to be used and the nominal volume of the ready vessel.
DN Capacity (l) 1 2 4 6 10 D d h Pack unit 1 1 1 1 1 Catalogue No. HAA HAA HAA HAA HAA 60060 60060 60060 60060 60060 03 04 05 06 07

100 100 150 150 150

106 140 200 215 240

106 155 155 155

145 210 215 245 335

Cylinders, round bottom


For manufacturing slim reaction vessels the use of these cylinders are recommended. The flange can be directly set on the rim. Other diameters are available on request. Seals, connections and triple clamp, which fulfils several functions ( separate support of the vessel and lid and connecting both parts) you will find in catalogue part "Components" chapter 5. If reaction vessels shall be used at higher operating pressures, please contact us to co-ordinate the technical data before delivery of the semi-finished products. The indication "DN" in the following table refers to the nominal size of the laboratory flat flange to be used.
DN D h Pack unit 1 1 1 1 1 Catalogue No. HAA HAA HAA HAA HAA 60030 60030 60030 60030 60030 03 04 05 06 07

60 100 120 150 200

65 105 130 160 215

400 400 400 400 400

NORMAG 2005

2.5

LABORATORY GLASSWARE
Lids
Lids type A are only available in small nominal sizes and not ground, type B are flat ground. Both types do not have a groove. Grooves are only necessary on one side and normally vessels with a groove are used.
DN 60 100 100 120 150 200 H 42 44 65 70 70 95 Type A A B B B B Pack unit 6 4 3 4 2 2 Catalogue No. HAA HAA HAA HAA HAA HAA 60040 60040 60041 60041 60041 60041 02 03 02 03 04 05

Flanges
They are readily ground and available with or without groove according to DIN 12 214.
DN 60 100 120 150 200 d 68 106 130 155 215 h 50 60 60 75 75 Pack unit 2 2 2 2 2 Catalogue No. with groove HAA HAA HAA HAA HAA 60050 60050 60050 60050 60050 02 03 04 05 06 Catalogue No. without groove HAA HAA HAA HAA HAA 60051 60051 60051 60051 60051 02 03 04 05 06

2.6

NORMAG 2005

LABORATORY GLASSWARE
ACCESSORIES FOR LABORATORY FLAT FLANGES
To connect vessel and lid to a reaction vessel ready for use seals and clamps are necessary. Both parts are described below.

O-ring seals
These O-rings, made of silicone and FEP-lined, have a very high elasticity, ensuring a good recovery and re-use. On request O-rings made of silicone or Viton are available. The indication "DN" in the following table refers to the nominal size of the laboratory flat flange.
DN 60 100 120 150 200 dxs 75 110 133 157 215 x x x x x 4 4 4 5 5 Pack unit 1 1 1 1 1 Catalogue No. HAA HAA HAA HAA HAA 60080 60080 60080 60080 60080 02 03 04 05 06

Quick release clamps


They ensure a quick and stable connection of vessel and lid. All quick release clamps are fitted with 3 retaining clips and are made of stainless steel. The indication "DN" in the following table refers to the nominal size of the laboratory flat flange.
DN 60 100 120 150 200 Pack unit 1 1 1 1 1 Catalogue No. HAA HAA HAA HAA HAA 60085 60085 60085 60085 60085 02 03 04 05 06

Triple clamp
This triple clamp is especially suitable for vessels with laboratory flat flanges and fulfils several functions at the same time: the connection of lid and vessel and separate support of lid and vessel. The lid is easy to dismantle e.g. for cleaning, and the vessel is still tightly connected with the frame.
DN 60 100 120 150 200 Pack unit 1 1 1 1 1 Catalogue No. VAB VAB VAB VAB VAB 09490 09490 09490 09490 09490 01 02 03 04 05