You are on page 1of 2

HSI20

String Inverter Transformerless Inverter


The string inverter HSI20 is a special transformerless development for TN-grids. The inverter was designed using the newest eciency-op mized technology in order to get higher returns from the solar installa on. Right from the start, all devices to be installed were chosen with respect to loss reduc on: The IP65 casing is especially developed for outdoor use and is protected against dust and water. The clear display enables the visualiza on of the last 365 days. The monitoring can be provided with our Data Logger and our so ware as well as with the solar log. The sum of these measures leads to a maximum eciency of 98.0 %. The EU eciency reaches outstanding 97.6 %. This high eciency is unique for inverters of this technology and oers mul ple advantages to the user: More energy from the photovoltaic array is fed to the grid, therefore a higher rate of return is obtained. Less waste heat has to be dissipated out of the already warm opera ng room. The reduc on of losses increases the life me of the internal components. The system is designed for low maintenance and long life me. Within the development process of the HSI20, a major design criterion was the simpleness and safety of the opera ng system for the inverter. This was achieved by a clear desktop. The inverter automa cally stores all relevant measuring data over a period of up to one year. The extreme silent inverter can be used anywhere.

HSI20

Helios Systems Wind&Sun Technologies Company Inverters made by FeCon GmbH www.helios-systems.net Tel.: 0049 461 430 122-0 Fax: 0049 461 430 122-11 E-Mail: info@fe-con.com

Technical Data Version 1.6

Technical Data HSI20


Electrical Data
Rated AC-power at 10 % of rated grid voltage Maximum AC-power at rated grid voltage Rated grid voltage other voltage levels and frequencies on request Short circuit level Maximum AC-current Line power factor (cos ) at 20% rated power AC-current distor on (THD) at rated power Rated PV-power within 10 % of rated grid voltage Maximum PV-power at rated grid voltage Maximum PV-current Maximum PV no-load-voltage MPP-area at rated PV-power Control strategy MPPEciency at (10|30|50|75|100) % power EU eciency incl. transf. losses / inductor and auxiliary losses EU eciency incl. transf. losses / inductor, excl. auxiliary losses EU eciency excl. auxiliary losses Feed-in star ng at Standby losses / at night Maximum auxiliary power General Data Ambient temperature (others on request) Rela ve humidity non-condensing Maximum al tude without dera ng in power Cooling type Minimum air quality acc. to EN60721-3-3 Protec on class Dimensions H x W x D Weight Container surface Colour of cabinet / colour of container (others on request) EMI Grid quality requirements Approval Grid monitoring CE-conformity Features DC-disconnector AC-disconnector Display Earth leakage detec on Surge arresters LVRT-Handling Communica on Cabinet Hea ng Opons Data Logger DL20 Solarlog DC-disconnector Grid contactor Graphical display black and white -20C to 40 C / 60C, power reduced < 90 % Forced air cooling IP65 (Elektronic), IP55 (other) 960 mm x 612 mm x 278 mm 65 kg Powder coated aluminum Complies EN 6100-6-2, EN 61000-6-4 Complies EN 50178 Complies VDEW requirements Complies 20 kW 21 kW 400 V, 3~, 50 Hz, TN-grid 63 A > 0,99 <3% 18 kW - 25 kW 22 kW 2 x 30 A 1000 V 350 V= to 1000 V= MPP-Tracking max. 98,1% 97,5% 40 W <3W

Helios Systems Wind&Sun Technologies Company Inverters made by FeCon GmbH www.helios-systems.net Tel.: 0049 461 430 122-0 Fax: 0049 461 430 122-11 E-Mail: info@fe-con.com

You might also like