JFR FMCW Radar Level Transmitter
JFR FMCW Radar Level Transmitter
PRODUCT INTRODUCTION
FMCW Radar level transmitter is a non contact measuring device, which is suitable for high temp., high pressure, and corrosive applications. It is easy to install and free of maintenance, especially for the high accuracy requirement environment.
FEATURES
Non contact measuring Corrosive and toxic liquid, hydrocarbons, slurries Not affected by specific gravity, pressure, temperature, viscosity, foam, and dust 5 digits LCM display Indicate signal wave inside the silo. Selection of Different Measurement unit(m, cm, mm, inch, ft, %, mA) Measuring distance and actual level. Language selection of traditional Chinese, simplified Chinese, English. 4-20mA/ 4 lead wires Modbus RS-485 to enhance isolation and easy for remote control. CE standards for isolation(EFT 2000V, B class or better) Suitable for mid-range signal 4mA, 20mA output Set functions to the continuous measuring device via FAS software. Isolated circuit design.
PRINCIPLE
FMCW radar adopts a high frequency signal, which is emitted via an antenna and swipe frequency increment by 0.5GHz during the measurement, reflected by the target surface and received at a time delay. The frequency difference, which is calculated from the transmitting frequency and the received frequency, which is directly proportional to the measured distance (or material surface). The frequency difference then is processed by Fast Fourier Transformation (FFT) to identify the signal in Intermedium Frequency (IF). This FMCW radar is innate with signal / noise enhancement and filtering of echo-back via Phase-Lock Loop (PLL) circuit that is the best solution for complex environment and high accuracy measurement.
Design formula
TEST STANDARDS
High voltage : Isolated resistance : Power supply change : Power supply failure : Electrical burst testing : Voltage DIPS : Humidity : High/Low temperature test : Protection rating IP65 : IEC60947-2 IEC60092-504 IEC60092-504 IEC60092-504 IEC61000-4-4 IEC61000-4-11 IEC60068-2-30 IEC60068-2-1&2 IEC60529
A0.2%
Distance to flange
SPECIFICATION
f117
f117
f117
203 1/2PF 1/2PF 20 DN100 PN16 FLANGE 8-f18 P.C.D f180 DN100 PN16 FLANGE 8-f18 202 P.C.D f180
203
Dimensions (Unit:mm)
20
202
f140
f140
f140
Model Measuring range Accuracy Repeatability Digital comm. Ambient temp. Operating temp. Operating pressure Frequency Analog output Power consumption Protection rating Min. dielectric constant Power supply Local display Housing material Antenna type Antenna material Sampling rate Blind distance
JFR-100-9-999A
20m(max.30m) A5mm (1m~5m) A2.5mm RS485(Isolated) -20~70BC -20~200BC 0~40 bar X Band 4~20mA/ 4 Wire 100mA/ 24Vdc IP65 2.5 24VdcA10% 5 digits LCM display Aluminum Horn
JFR-100-9-999B
20m(max.30m) A10mm (1m~5m) A5mm RS485(Isolated) -20~70BC -20~200BC 0~40 bar X Band 4~20mA/ 4 Wire 100mA/ 24Vdc IP65 2.5 24VdcA10% 5 digits LCM display Aluminum Horn
JFR-100-9-999C
20m(max.30m) A20mm (1m~5m) A10mm RS485(Isolated) -20~70BC -20~200BC 0~40 bar X Band 4~20mA/ 4 Wire 100mA/ 24Vdc IP65 2.5 24VdcA10% 5 digits LCM display Aluminum Horn
SUS 304/ 316/ PTFE Coating SUS 304/ 316/ PTFE Coating SUS 304/ 316/ PTFE Coating 1sec. 0.5m 2 1sec. 0.5m 1sec. 0.5m
SPECIFICATION
f117
f117
209
Dimensions (Unit:mm)
f155
425
Model Measuring range Accuracy Repeatability Digital comm. Ambient temp. Operating temp. Operating pressure Frequency Analog output Power consumption Protection rating Min. dielectric constant Power supply Local display Housing material Antenna type Antenna material Sampling rate Blind distance
JFR-110-9-999C
10m A20mm (1m~5m) A10mm RS485(Isolated) -20~70BC -20~150BC 0~16 bar X Band 4~20mA/ 4 Wire 100mA/ 24Vdc IP65 4 24VdcA10% 5 digits LCM display Aluminum Wave Stick PTFE 1sec. 0.6m
JFR-110-9-999D
10m A30mm (1m~5m) A15mm RS485(Isolated) -20~70BC -20~150BC 0~16 bar X Band 4~20mA/ 4 Wire 100mA/ 24Vdc IP65 4 24VdcA10% 5 digits LCM display Aluminum Wave Stick PTFE 1sec. 0.6m 3
WIRING/CALIBRATION
WIRING INFORMATION
RS485 wiring
1 2 5 6 V+ V-
CALIBRATION
Two ways to calibrate the JFR Series: 1. With display/adjustment module 2. By PC based FAS software
POWER DC24V
TR- TR+
Adjustment module is an adjustment tool with 4 buttons to click on. It also has a transparent window to allow display reading.
1 2 3 4
V+ V-
POWER DC24V
I+ I-
Panel Meter
1 2 3 4
WIRING DIAGRAM
1 2 3 4 5
6 5 4 3 2 1
Power Supply: V+ Power Supply: VAnalog Output: I+ (4~20mA) Analog Output: I- (4~20mA) Communication: TR+ (Rs485) Communication: TR- (RS485)
QUICK SETUP
SETTING MENU LOW POINT HIGH POINT BLIND AREA MAX RANGE
1.1
MAX RANGE
1.1.6
04500
1.1.2
SETTING MENU
LOW POINT HIGH POINT BLIND AREA MAX RANGE
MM
M CM MM INCH FT % MA
16.272
Press + for 3 seconds to enter main menu
1
00000
SETTING MENU LOW POINT HIGH POINT BLIND AREA MAX RANGE
MM
Enter distance between flange and high level by using and Click on to save and return to 1.1
1.1
Press
MAIN MENU SETTING DISPLAY DIAGRAM SERVICE
00500
SETTING MENU LOW POINT HIGH POINT BLIND AREA MAX RANGE
MM
04500
Enter blind distance counting from flange by using and . Click on to save and return to 1.1
1.1
MM
Enter distance between flange and low level by using and . Click on to save and return to 1.1
Save and click on to return to 1.2. click on twice to return to the display.
FINE-TEK
M CM MM INCH FT % MA
16.272
DIAGRAM
Measurement bench-mark starts at contact surface of connection. Low level calibration (menu 1.1.1) High level calibration (menu 1.1.2) Blind Distance (menu 1.1.5) Measuring Distance Setup (menu 1.1.6) Note: Be aware of blind distance when measuring material high level.(Shown in )
100%
0%
INSTALLATION
If the JFR-110 is installed on a neck, refer to the limitation on the length and the diameter as below.
The horn of the JFR-100 can not hide in the neck. The horn has to expose itself to the tank by 0.39 at least
The axis direction of FMCW should be parallel with the wall, or be in orthogonal with the surface. For Install, the distance from the wall should >1/3 D, and the height from the surface >1/5 H (Measurement Depth) is recommended.
>1/5H Max.<1/3D H
Device has to be installed away from the tank wall to avoid disturbance caused by reflection.
The turbulent or stirring will make the bubble and vortex that might interface with the measurement, it is recommended to install wave shield tube with vent hole To avoid from this situation.
vent hole
X
Device has to be installed away from the tank wall to avoid incorrect reflection.
X
Device is to be installed away from material inlet to avoid disturbance caused by material or other obstacles.
X
A reflector is recommended to be installed when there is disturbing obstacle to avoid false reflection.
X
Please avoid center installation for arched top tanks for possible multiple reflection.
Reflector
X
Sun/rain block is recommended for outdoor application.
X
The best installation position for cone shape tank with flat top is at the center spot for full measuring range.
X
7
ORDERING INFORMATION
JFR-1
Type
0: Horn Antenna Type3 (Length 202mm,opening140mm) Standard 1: Horn Antenna Type2 (Length 126mm,opening100mm) 2: Horn Antenna Type1 (Length 89mm,opening80mm) 3: Rod Antenna (Length 425mm) Standard 4: Rod Antenna (Length 525~825mm) Lengthened
R 0 1
Material
0: SUS304---Horn Antenna 6: SUS316---Horn Antenna E: PTFE------Horn Antenna or Wave Rod Antenna with PTEE coating F: PTFE------Rod Antenna
Accuracy
A: A 5mm C: A 20mm B: A 10mm D: A 30mm
Connection
Size for flange or screw
G: 2-1/2"(65A) H: I: 4"(100A) 3" (80A) J: 5"(125A) K: 6"(150A) S: Others
W: PN10 (10Bar)
2 N: 10kg/cm JIS X: PN16 (16Bar) O: 150Lbs ANSI Y: PN25 (25Bar) P : 300Lbs ANSI Z: PN40 (40Bar) S: Others
Horn Antenna Type3--- 4"(Min.)(In case of applying in protective tube, the minimum flange size is 6") Wave Rod Antenna --- 2-1/2"(Min.)
Flange Material
Meral Plastic 0: SUS304 P: PP 5: SS41 zinc coating E: PTFE 6: SUS316
Housing
R:Aluminum(IP65)
[FC/FD] [FG] [FF] [FA/FB] [SP] [SF] [SD] [SE] [SA] [EC] [LR] [SC] [SC] [EB] [SB] [EG] [EF] [MEF] [EA] [JFR] [EE]
Magnetic Float Level Transmitter Side Mounting Float Switch Cable Float Level Switch Thermal Dispersion Flow Switch Paddle Flow Switch Optical Level Switch Rotary Paddle Level Switch Capacitance Level Switch Pressure Level Transmitter Loop Power Indicator Vibrating Probe Level Switch Tuning Fork Level Switch RF-Capacitance Level Transmitter RF-Capacitance / Admittance Level Switch Magnetostrictive Level Transmitter By-Pass Level Transmitter Mini By-Pass Level Transmitter Ultrasonic Level Transmitter FMCW Radar Level Transmitter Electromechanical Level Measuring System
[SE] [SB] [SC] [EB] [SB] [EF] [EB] [FA/FB] [EG]
[EA]
[SC] [SA]
[FF] [SF]
[FC/FD]
[SP] [PB/PM]
[EE]
[SC]
[JFR] [EB]
[SA]
[SC]
[ED]
Speed Monitor
[SRT/SRS] Conveyer Belt Misalignment Switch & Safety Cable Pull Switch Microprocessor Based Bargraphic Display Scaling Meter [BAS/ Valve and Controller for Dust Collector System BAH/BVP] [BAS/BAH/BVP] Air Hammer [BRD/AE] [BVK/BVR/BVT] Pneumatic Vibrator [PB/PM]
[BVK/ BVR/BVT]
Taichung Branch TEL: 886 4 2337 0825 FAX: 886 4 2337 0836 Tainan Branch TEL: 886 6 289 0635 FAX: 886 6 289 4073 Kaohsiung Branch TEL: 886 7 333 6968 FAX: 886 7 536 8758
FineTeK GmbH
Frankfurter Str. 62, OG D-65428 Ruesselsehim, Germany TEL: 49 6142 17608 0 FAX: 49 6142 17608 20 E-Mail: info@fine-tek.de