You are on page 1of 6

Intra Freq

rptRange
Reporting Range Constant for Event 1A/1B(dB)
double[7]:[0~14.5];default:3;5;0;0;0;0;0
Reporting Range Constant for Event 1A/1B
R-W-I
3;5;0;0;0;0;0
4;7;0;0;0;0;0

threshUsedFreq
Absolute Threshold of the Quality of the Currently Used Frequency for 2B/2D/2F(dB)
long[6]:[-24~0];default:-24;-13;-24;-13;-24;-8
Inter-Freq
Absolute Threshold of the Quality of the Currently Used Frequency for 2B/2D/2F
R-W-I
-24;-13;-24;-13;-24;-8

threshSys
Absolute Threshold of the Quality of Other RAT for 3A/3B/3C(dBm)
long[4]:[-115~-25];default:-90;-95;-95;-115
Inter-RAT
Absolute Threshold of the Quality of Other RAT for 3A/3B/3C
R-W-I
-90;-95;-95;-115

hysteresis
Hysteresis(dB)
double[7]:[0~7.5];default:0;0;4;4;2;2;4
Hysteresis
R-W-I
0;0;4;4;2;2;4

hysteresis
Hysteresis(dB)
double[6]:[0~14.5];default:4;4;4;4;4;4
Hysteresis
R-W-I
4;4;4;4;4;4

hysteresis
Hysteresis(dB)
double[4]:[0~0],[0.5~7.5];default:4;4;2;4
Hysteresis
R-W-I
4;4;2;4

trigTime
Time to Trigger(ms)
long[7]:[0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15];default:9;12;11;11;9;9;11
Time to Trigger
R-W-I
9;12;11;11;9;9;11

trigTime
Time to Trigger(ms)
long[6]:[0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15];default:6;6;6;12;6;12
Time to Trigger
R-W-I
6;6;6;12;6;12

threshUsedFreq
Absolute Threshold of the Quality of the Currently Used Frequency for 2B/2D/2F(dBm)
long[6]:[-115~-25];default:-115;-95;-115;-95;-115;-80
Absolute Threshold of the Quality of the Currently Used Frequency for 2B/2D/2F
R-W-I
-115;-95;-115;-95;-115;-80

hysteresis
trigTime
Hysteresis(dB)
Time to Trigger(ms)
double[6]:[0~14.5];default:4;4;4;4;4;4
long[4]:[0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15];default:6;6;6;6
Hysteresis
Time to Trigger
R-W-I
R-W-I
4;4;4;4;4;4
6;6;6;6