You are on page 1of 2

References

Prepared(alsosubjectresponsibleifother)
Docrespons/approved Date Rev
Productname
DocumentNo. Sheet
DrawingRules
Tolerances
Scale
E EmersonNetworkPower
EnergySystems
P
R
O
P
R
I
E
T
A
R
Y

I
N
F
O
R
M
A
T
I
O
N
T
h
i
s

d
o
c
u
m
e
n
t

a
n
d

t
h
e

c
o
n
t
e
n
t
s

h
e
r
e
i
n

i
s

C
O
N
F
I
D
E
N
T
I
A
L

a
n
d

t
h
e

s
o
l
e

p
r
o
p
e
r
t
y

o
f

E
m
e
r
s
o
n
.

R
e
p
r
o
d
u
c
t
i
o
n

d
i
s
t
r
i
b
u
t
i
o
n
o
r

u
n
a
u
t
h
o
r
i
z
e
d

u
s
e

o
f

t
h
i
s

d
o
c
u
m
e
n
t

o
r

a
n
y

p
a
r
t
s

w
i
t
h
i
n

t
h
i
s

d
o
c
u
m
e
n
t

i
s

f
o
r
b
i
d
d
e
n

w
i
t
h
o
u
t

t
h
e

w
r
i
t
t
e
n

c
o
n
s
e
n
t

o
f

E
m
e
r
s
o
n
.
DRAWING- TERMINALDIAGRAM CompanyWideInternal
ProductCode
(See PDM)
Yahya Sam
11 CR 5932 BQ
2008-10-20 A
Legacy Alias
BMG 653 39/2X CB (5x)-(12x) 2p type (L-L)
1 4 2 3 5 6
Connection of
incoming AC
Connection made to upper rectifier shelf Connection made to lower rectifier shelf
AC Terminal NET 104 029/1 (1-4x)
1(2)
L
N
PE
+
-
Rectifier shelf from back
Earth cables to terminal
PE
SET 103 01
To chassis on
rectifier shelfs
To next rectifers
S1 S2 S3 S4 S5 S6
S7 S8 S9 S10 S11 S12
Rectifiers in
upper shelf (1)
Rectifiers in
lower shelf (2)
N
L
S2,S5, S8,S11
S1,S4, S7,S10
S3,S6, S9,S12
Mounted
Enclosed
in package
Mounted
Mounted
Enclosed
in package
1 4 2 3 5 6
Connection of
incoming AC
Mounted
Mounted
Enclosed
in package
1 4 2 3 5 6
Connection of
incoming AC
Mounted
Mounted
Enclosed
in package
1 4 2 3 5 6
Connection of
incoming AC
Mounted
Mounted
Enclosed
in package
AC terminal BMY 107 247/1
AC cable close to top of
rectifier shelf.
Important for good EMC
behavior and not to cover
air outlet.
AC Distribution
AC Terminal
Connection
25mm
1 2 3 4 5 6
1 2 3 4 5 6
F
E
D
C
B
A
F
E
D
C
B
A
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
L L
F12
Connection made to
upper rectifier shelf
PE
To chassis on
rectifier shelfs
Connection of
incoming AC
Internal wiring see documents for unit
L L L L
L L L L
L L L L L L
L L L L L L L L
L L L L L L L L
L L L L L L L L L L
L L L L L L
Space for
BMY 107 220/1
(Optional)
1 2 3 4 5 6 Connection for
400/230Vac
Marking and
jumpersenclosed
1
2
4
5
6
L1 L2 L3 N
N N
S
1

L
S
2

L
S
3

L
S
1

N
S
2

N
S
3

N
S
4

L
S
5

L
S
6

L
S
4

N
S
5

N
S
6

N To chassis on
rectifier shelf
1 4 2 3 5 6
Connection of
incoming AC
Mounted
Mounted
Enclosed
in package
AC Terminal NET 104 027/1 (1x)
* * *
*
*Fixed togheter
two by two
50
AC terminal
NET 104 029/1 (1-4x)
Or
NET 104 027/1 (1x)
BMY 107 247/1 (1x)
To rectifier pos
1 2 3 4 5 6
N
L
N
L
S
1

L
S
2

L
S
3

L
S
1

N
S
2

N
S
3

N
S
4

L
S
5

L
S
6

L
S
4

N
S
5

N
S
6

N
S
7

L
S
8

L
S
9

L
S
7

N
S
8

N
S
9

N
S
1
0

L
S
1
1

L
S
1
2

L
S
1
0

N
S
1
1

N
S
1
2

N
Connection made to
lower rectifier shelf
To chassis on
rectifier shelf
S
1

L
S
2

L
S
3

L
S
1

N
S
2

N
S
3

N
S
4

L
S
5

L
S
6

L
S
4

N
S
5

N
S
6

N
To chassis on
rectifier shelf
To chassis on
rectifier shelf
S
7

L
S
8

L
S
9

L
S
7

N
S
8

N
S
9

N
S
1
0

L
S
1
1

L
S
1
2

L
S
1
0

N
S
1
1

N
S
1
2

N
To chassis on
rectifier shelf
Rectifier connection
L=Black
N=Blue
Electrical safety
Cable tie max 20mm from
component
Note! All stripped cable
ends should be provided
with jonting sleeves
A A
A-A
Fixed togheter
3by 3
S
C
U
DC Distribution
Power System DC BZA 108 35
Compact System
L1 L2 L3 N PE
S1 S2 S3 S4 S5 S6
S7 S8 S9 S10 S11 S12
1 2 3 4 5 6
1 2 3 4 5 6
F
E
D
C
B
A
F
E
D
C
B
A
References
Prepared(alsosubjectresponsibleifother)
Docrespons/approved Date Rev
Productname
DocumentNo. Sheet
DrawingRules
Tolerances
Scale
E EmersonNetworkPower
EnergySystems
P
R
O
P
R
I
E
T
A
R
Y

I
N
F
O
R
M
A
T
I
O
N
T
h
i
s

d
o
c
u
m
e
n
t

a
n
d

t
h
e

c
o
n
t
e
n
t
s

h
e
r
e
i
n

i
s

C
O
N
F
I
D
E
N
T
I
A
L

a
n
d

t
h
e

s
o
l
e

p
r
o
p
e
r
t
y

o
f

E
m
e
r
s
o
n
.

R
e
p
r
o
d
u
c
t
i
o
n

d
i
s
t
r
i
b
u
t
i
o
n
o
r

u
n
a
u
t
h
o
r
i
z
e
d

u
s
e

o
f

t
h
i
s

d
o
c
u
m
e
n
t

o
r

a
n
y

p
a
r
t
s

w
i
t
h
i
n

t
h
i
s

d
o
c
u
m
e
n
t

i
s

f
o
r
b
i
d
d
e
n

w
i
t
h
o
u
t

t
h
e

w
r
i
t
t
e
n

c
o
n
s
e
n
t

o
f

E
m
e
r
s
o
n
.
DRAWING- WIRINGDIAGRAM CompanyWideInternal
ProductCode
(See PDM)
Yahya Sam
2008-10-20 A
Legacy Alias
Rectifiers in upper shelf (1)
Rectifiers in lower shelf (2)
Example for Distribution Unit
Multi Function Unit
For Internal connections
refer to 11UY5443FN or
11UB2291DD
11 CR 5932 BQ
2(2)
Power System DC BZA 108 35
Compact System
23"
S3 S2 S1
Multifunction Unit
S
C
U
S4 S6 S5
BMK 445 121/1
S
C
U
50
2
30
4
1
3
23"
DC
distribution
S3 S2 S1
SCU Batt CB
S4
BMK 445 901/54
19"
DC
distribution
S3 S2 S1
SCU Batt CB
BMK 445 901/53
CAN bus connection
CAN bus connection
CAN terminal resistor
RPM628350/2
Differnt BMK configurations
Alarmin fromother
board
RPM 628 251/1 or 2
RPM 628 386/1 or 2
RPM 628 991/1
RPM 628 453/1 or 2
RPM 628 453/1 or /2
1
X4
X3
X1
ROA1190786/1
1
X4
X3
X1
ROA1190786/1
1
X4
X3
X1
ROA1190786/1
1
X4
X3
X1
ROA1190786/1
19"
S3 S2 S1
Multifunction Unit
S
C
U
S4 S5
S6 S7 S8 S9 S10
BMK 445 901/55
23"
S3 S2 S1
Multifunction Unit
S
C
U
S4 S6
S7 S8 S9 S10 S12
S5
S11
BMK 445 901/56

You might also like