You are on page 1of 13

BILL NO :1 OFFICE BUILDING - WATER SUPPLY SCHEME

Note 1. All rates & prices shall be excluive of VAT, Which should only be shown separately in summery.
As for the tender eveluation purposes these rates & prices will be considered to be exclusive of VAT.
Ite
m
No

SLS573
code

Discription

Qty

Unit

344

02

nr

02

nr

04

Rate

Amount

SECTION - D
EXCAVATION AND EARTH WORK

D.1.1.1

D.1.2.1

D.1.2.2

D.2.4.1
D.2.4.2
D.2.5.1

D.2.5.2

D.7.2.1

D.7.2.1

D.8.3.1

EXCAVATING
Clearing
Site preparation for cearing site vegetation 3m
away from outer wall and filling voids with
selected earth as directed by engineer
site preparation for removing trees girth
>500m and 1000mm and filling voids with
selected earth as directed by engineer
site preparation for removing trees girth
>1000m and 1500mm and filling voids with
selected earth as directed by engineer
Excavation and earth work
Excavation pits for columns depth not
exceeding 1.0m commencing from ground
level

Excavation pits for columns depth not exceeding 1.0m 0.70


not exceeding
m 2.0m commencing from ground level
Excavation for foundation trenches width
exceeding 300mm and depth not exceeding 1.0m
29
m
commencing from ground level
Excavation for foundation trenches width
exceeding 300mm and depth exceeding 1.0m not
exceeding 2.0m commencing from ground level
Categery B timber or suitable material for
earthwork support for pits total depth not
exceeding 2.0m and distance between opposing
faces 2m
Categery B timber or suitable material for
earthwork support for foundation trenches total
depth not exceeding 2.0m and distance between
opposing faces 2m
Disposal of excavated material away from site as
directed by the engineer
Total of page no 01

Page 1 of 13

4.9

171

19

44

D.9.1.1

Filling to excavation with selected excavated


material an average depth 900mm and filling with
150mm thick layers watered compacted and well
rammed

3.4

D.9.3.1

Filling to make up level with selected excavated


material an average depth 200mm thick layers
watered compacted and well rammed

20

D.9.3.1

Filling to make up level with selected excavated


material an average depth50 mm thick layers
watered compacted and well rammed

3.2

D.9.3.1

Filling to make up level with selected excavated


material an average depth 125mm thick layers
watered compacted and well rammed

1.5

SECTION F
CONCRETE WORK
Reinforcement and formwork measured
seperately uless otherwise stated.

SECTION F2
INSITU CONCRETE
Mass concrete- Grade 15
F1.18.1

50

F1.3.1.1
F1.3.1.1
F1.3.1.1

concrete channel having 100mm thick walls,


concrete drains complete as shown in detail
drawing
In 100mm thick concrete bed and slab on ground
In 125mm slab to slope ramp
In 150mm slab to slope porch ramp

12
4.6
0.3

m
m
m

F1.14
F1.2.2.2
F1.2.3.2

Reinforced Concrete - Grade 25


in lintels
In bases of column
In column shaft upto finish first floor level

1.1
0.8
0.7

m
m
m

Total of page no 02

SECTION F2
FORMWORK
formwork in approved timber. Rate to include
for splayed edges, battens, strutting, bolting,
wedging, easing, striking, and removal

Page 2 of 13

F2.1.2.1

200 mm height category B timber or suitable


material rough finish formwork for sides of
column bases
Catogory B timber or suitable materialfor sides of
attached isolated columns
Catogory B timber or suitable materialfor sides of
attached square columns
In sides and soffit of isolated square beam
To sides and soffit of lintels

18

3.2

10
16

m
m

F3.1.1.7
F3.2.1.7
F3.2.2.7

For beams and lintels


6mm diameter mild steel bars
10mm diameter tor steel bars
12mm diameter tor steel bars

0.02
0.04
0.06

t
t
t

F3.1.1.1
F3.2.1.1
F3.2.2.1

For column
6mm diameter mild steel bars
10 mm diameter tor steel bars
12mm diameter tor steel bars

0.02
0.03
0.07

t
t
t

225mm thick vertical common brick solid walls in


cement sand mortar 1:5 with English bond.

167

113mm thick vertical common brick solid walls in


cement sand mortar 1:5 with Streacher bond.

53

F2.12.1.1
F2.12.2.1
F2.13.1.1
F2.14.2.1

SECTION F3
REINFORCEMENT IN INSITU CONCRETE

Tor/ild steel rod reinforcement cut to lengths,


bent to shape, placed in position and tied with
GI wire

SECTION - G
MASONRY WORK
SECTION G1 - BRICK WORK /
BLOCK WORK
G1.1.1.1.1

G1.1.1.1.1

SECTION G2 -STONE WORK


Total of page no 03

Page 3 of 13

Random rubble masonry vertical


foundation in cement sand mortar 1:5
G2.1.1.1.1
G2.1.1.1.1
G2.1.1.1.1
G2.1.1.1.1

475mm wide
350mm wide
375mm wide
250mm wide

66
16
16
04

m
m
m
m

16

21

07

nr

SECTION -H
WATER PROOFING
H.2.1.1

H.2.2.1

20 mm thick horizontal damp proof course in


cement sand mortar 1:3 on 250mm wide rubble
foundaton and treated with two coats of hot tar
and blinded with sand
20 mm thick horizontal damp proof course in
cement sand mortar 1:3 on 350mm wide rubble
foundaton and treated with two coats of hot tar
and blinded with sand

SECTION - K
METAL WORK
Doors and windows
All materials supplied,fabricated and fixed in
position complete as shown in detail on drawing
and as specified .Provition shall be made for
breaking walls / concrete floors whenever
necessary and making goood as directed.
Rate to be included for supply and fix heavy
quality brass ironmongory , inclding fixing with
with brass screws to match and fixing of
security grills for windows and fanlights as
directed
K.1.1

Glazed panelled with Aluminium frame window


(type W1) of size 1800*1650mm,complete as
shown in detail on drawing and as specified.
Total of page no 03

Page 4 of 13

K.1.1

K.1.1

K.3.1

K.6.1

K.6.1

K.6.1

K.7.1

K.9.1

Glazed panelled with Aluminium frame window


(type W2) of size 500*1650mm,complete as
shown in detail on drawing and as specified.
Glazed panelled with Aluminium frame fanlight
(type F1) of size 500*750mm,complete as shown
in detail on drawing and as specified.
Glazed panelled with Aluminium louvers(type F2)
of size 500*750mm,complete as shown in detail
on drawing and as specified.
Glazed panelled with Aluminium frame door
(type D1) of size 1200*2550 complete as shown
in detail on drawing and as specified
Glazed panelled with Aluminium frame door
(type D2) of size 900*2550mm,complete as
shown in detail on drawing and as specified.
Aluminium frame with marine type plywood door
(type D3) of size 750*2100mm complete as
shown in detail on drawing and as specified
Aluminium roller shutter (type RS) of size
4000*2550 ,complete as shown in detail on
drawing and as specified.
Glazed and Aluminium Slidding door (type SD2)
of size 900*2100 ,complete as shown in detail on
drawing and as specified.

02

nr

05

nr

03

nr

01

nr

01

nr

02

nr

01

nr

04

nr

30
4.8
357
34
321

m
m
m
m
m

SECTION - L
WOOD WORK
Supplying and fixing category 'B' wrought
timber for following items, complete as shown
in drawings and as directed. Rateto be
included for applying approved quality wood
preservative on all timber surfaces.
L1.4.3.1
L1.4.4.1
L1.4.5.1
L1.4.5.1
L1.4.6.1

75x125mm purlin
50x175 mm ridge plate
50x100 mm rafters
150x175 mm hip rafters
50x50 mm runner
total of page no 05
Page 5 of 13

L1.4.7.1
L1.4.7.1

75x100 mm wall plate


75x150 mm beam

39
8.3

m
m

9.9

8.2

5.1

7.4

7.6

SECTION - N
PARTITIONS
Partition work
partitioning supplied or fabricated and fixed in
position complete as shown in detail on drawing
and as specified. Provision shall be made for
breaking walls and concrete floor etc. whenever
necessary and making good as directed.

partition type
N.4.1.1.1

N.4.1.1.1

N.4.1.1.1

N.4.1.1.1

N.4.1.1.1

partition, type p3 3660x2700mm power coated


aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
partition, type p2 3050x2700mm power coated
aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
partition, type p1 1890x2700mm power coated
aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
partition, type p4 2740x2700mm power coated
aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
partition, type p5 2815x2700mm power coated
aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
total of page no 06

Page 6 of 13

N.4.1.1.1

N.4.1.1.1

N.4.1.1.1

partition, type p6 2540x900 mm power coated


aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
partition, type p7 3275x900 mm power coated
aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing
partition, type p8 3038x900 mm power coated
aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And
5mm thick glazed partition. All inclusive as per
drawing

2.3

2.9

8.2

20

10

13
10

nr
nr

SECTION - Q
PLUMBING/ SANITARY
INSTALLATIONS
All Fixtures shall be supplied and fixed
complete including effecting connection to
water main and disposal connection as
required.
All sanitory fittings shall be approved
quality make and colour unless otherwise
stated. P.V.C pipe (Type 1000)
specials,fittings and other material
supplying, laying, and jointing or fixing
completing walls with plated (P.V.C
brackets) involves as requires or laying
underground as directed.(Pipe diameter
50 mm shall be including all specials)

Q.1.1.2
Q.1.1.6
Q.2.1.1
Q.2.1.1

Note: The following quantities are


provisional.
Cold water service
20mm dia P.V.C straight pipes laying in
trenches
20 mm dia P.V.C straight pipes laying on
ground
20 mm elbow fittings
25 mm elbow fittings
total of page no 07
Page 7 of 13

Q.2.1.1
Q.2.1.1
Q.2.1.3
Q.2.1.3
Q.2.1.3
Q.2.1.3
Q.2.1.6
Q.2.1.6
Q.2.1.6
Q.14.1
Q.14.1
Q.14.1
Q.14.1
Q.14.1
Q.14.1

32 mm elbow fittings
50 mm elbow fittings
25x25 mm tee fittings
25x20 mm tee fittings
32x20 mm tee fittings
32x25 mm tee fittings
25-20 mm reducer fittings
50-32 mm reducer fittings
32-20 mm reducer fittings
20 mm dia stop valve
25 mm dia stop valve
32 mm dia stop valve
50 mm dia stop valve
Ball valve
25 mm dia non return valve

2
1
1
5
1
3
3
1
1
2
2
1
1
1
1

nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr

10

10
8

m
m

nr

nr

nr

nr

nr

10
10

m
m

nr

nr

Waste Water Service


Q.1.1.1
Q.1.1.1
Q.1.1.1
Q.2.1.2
Q.2.1.2
Q.2.1.3
Q.2.1.3
Q.2.1.3

50 mm dia uPVC waste water pipes laying in


concrete ducts.
63 mm dia waste water pipes laying in ducts
40 mm dia waste water pipes laying in ducts
Extraover for 63 mm dia PVC pipe for 90
bends
Extraover for 63 mm dia PVC pipe for 45
bends
Extraover for 63 mm dia PVC pipe for 63x63
mm tees
Extraover for 63 mm dia PVC pipe for 63x50
mm tees
Extraover for 63 mm dia PVC pipe for 63x40
mm tees
Sewage Disposal Section

Q.1.1.1
Q.1.1.1
Q.2.1.3
Q.2.1.2

110 mm dia PVC sewer pipe


110 mm dia PVC vent pipe
Extrover for 110 mm dia PVC pipe for
110x110 mm tees
Extraover for 110 mm dia PVC for long
radius bend
Fixutures and Appliances
total of page no 08

Page 8 of 13

All fixtures Shall be supplied and fixed


complete including effecting connection to
water main and disposal connection as
required.
All sanitary fittings shall be of approved
colour unless otherwise stated. As directed
by the Engineer.

Q.5.1.1

Q.5.1.1

Q.5.1.1

Europian type low level suite comprizing of


pedestral type water closet complete with
strap system. Seat cover and all necessary
accesaries all complete to woorking order as
directed by Engineer.
Wash basin pedestral type with chromium
plated high quality wash basin tap, waste plug
accesaries. All complete to working Order as
Directed by the Engineer.
600x500 mm bathroom mirror with plastic
frame complete with fittings

SECTION - S
ELECTRICAL INSTALLATIONS
Note : All condute pipes are to be
concealed in walls and ceiling.wiring to be
completed upto MCB.rate to be included
for necessary testing.
All materials of approved quality.(as per
IEE regulation) Supplying and fixing
completed as directed.rate to be included
for all pvc copper pvc wiring involved as
specified and switching including switches
with approved made complete to working
order. All fixes shall be approved quality
and made to the satisfaction of the
Engineer and as specification.
total no of page no 09

Page 9 of 13

nr

nr

nr

S.11.1.1
S.22.2.1
S.22.2.2
S.22.2.3
S.23.1
S.24.1
S.24.1
S.24.1
S.24.1
S.26.1
S.26.1
S.26.1

S.34.1.1

S.41.1.1

S.20.1

Main electrical cable 2x6 mm (pvc copper pvc)


from electricity meter point to main circuit breake
point
Final circuit for 5A socket outlet
final socket for ceiling fans
Final Circuit for lighting switches.
Final circuit for 5A socket outlet flush type
One way two gang switch
One way three gang switch
One way four gang switch
One way five gang switch
Wall bracket lamp with glass shades
Water tight pendent lamp with plastic globe
Double flourescent lamp with prismatic type
diffuser four feet long
Single phase 30 A ELCB with 8 number 6A
miniature circuit breakers in operated in plastic
box with hinged door. Rate to be included for
suitable buss bars.
Ceiling fans having 1400mm sweep with 5 speed
regulator and off position and necessary
accesaries
Earth electrodes complete with 50mm dia
1500mm long heavy guage GI pipe with a brick
gully driven into ground for connecting
framework connectivity conductor in order to
obtain satisfactory earth resistance reading as
required by IEE

20

14
10
40
14
7
1
2
3
3
11

nr
nr
nr
nr
nr
nr
nr
nr
nr
nr

17

nr

nr

10

nr

nr

26

38

SECTION - T
FLOOR FINISHES/CEILING FINISHES

SECTION F1 - FLOOR FINISHES


T1.1.1.1

T1.1.1.1

T1.1.1.1

12mm thick rendering in cemet sand mortar 1:3


finished smooth with neat cement floating of
approved colour.
12mm thick rendering in cemet sand mortar 1:3
finished smooth with neat cement floating of
approved colour on ramp.
12mm thick rendering in cemet sand mortar 1:3
finished rough floating of approved colour on
porch ramp.
total of page no 10

Page 10 of 13

T1.1.10.1

T1.1.11.1

T1.9.1

T1.9.1.1

T1.9.9.1

12 mm thick 100mm high plushed type skirting in


cement sand mrtar 1:3 and finished smooth with
cement floating to matching colour to floor
12mm thick render in cement sand mortar 1:3
finished smooth with neat cement floating of
approved colour on drain.
Non slip type ceramic floor tiles of approed
quality make and colour laid on concreete in toilet
and washing area including beding. In cement
sand mortar 1:2 with cement grout and joints
filled with cement grout of matching colour and
complete as directed by Engineer.
Homogenious ceremic floor tile of approved
quality and colour. Layed on concrete floor.porch,
clarical staff room, meter readers room, including
bedding in cement sand mortar 1:2 with cement
grout and joints filled with cement grout of
matching colour and complete as shown in
detailed drawing and as directed by Engineer.
12mm thick 100mm height 1:3 cement sand
mortar plush skirting to matching colour to the
floor

18

50

9.3

98

44

90

05

245

89

SECTION T2
WALL AND CEILING FINISHES

T2.1.1.1

T2.1.1.1
T2.1.2.1

T2.1.2.1

Internal plastering
62.5 wide 16mm thick internal doors and
windows reveals in cement , lime, sand 1:1:5 and
finished smooth with lime putty
113mm wide internal side of arch
16 mm thick internal plastering on brick wall in
cement lime and sand mortar 1:1:5 and finished
smooth with lime floor.
External plastering
16 mm thick external plastering on brick wall in
cement lime and sand mortar 1:1:5 and finished
withsemi rough surface.
Reveals
total of page no 11

Page 11 of 13

T2.1.1.1

T2.1.1.1
T2.1.1.1

T2.13.2

62.5 wide 16mm thick external doors and


windows reveals in cement , lime, sand 1:1:5 and
finished semi rough with lime putty
175 mm wide 16mm thick internal sides of the RS
16 mm thick internal plastering on brick wall in
cement lime and sand mortar 1:1:5 and finished
with fair finish.
200x200mm glazes ceramic wall tile in approved
colour and quality on cement sand 1:3 tile bed
and point with tile grout to match and forming
neat uniform joints between tiles in toilet area
including reveals

81

09

51

25

245

90

89

51

5.1

81

9.1

SECTION V
PAINTING
V.1.1.1

V.1.1.1

V.1.1.1

V.1.1.1

V.1.1.2.1

V.1.1.2.1

V.1.1.2.1

Apply two coates of wall primer an two coates of


approved quality and make luxury emulsion paint
on faces of internal walls.
Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint
on faces of internal doors and windows reveal.
preparing and apply two coates of primer and two
coates of emulsion weather sealing paint on faces
of extrnal walls
Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint
on faces of internal walls of bath room.
Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint
on faces of internal side of arch.
Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint
on faces of external doors and windows reveal.
Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint
on faces of internal sides of RS.

SECTION W
total of page no 12

Page 12 of 13

DRAINAGE SYSTEM BELOW GROUND


(following quantities are provisional)
W.13.1.1

W.15.1.1

W.16.1.1

construction of 600x600 mm brick masonry man


hole. All complete as directed by Engineer.
construction of internal diameter 900mm brick
masonary black water soakage pit. All complete
as directed by Engineer.
construction of 1000x1000 mm brick masonry
waste water pit. All complete as directed by
Engineer.

total of page no 13
Page 13 of 13

nr

nr

nr

You might also like