Professional Documents
Culture Documents
Features
Optional
Field-Selectable
Outputs
Allows you to stock only one
unit for all outputs
Approved for
Natural Gas
When purchased with option (E)
RFI/EMI Protected
Eliminates susceptibility to
electromagnetic intereference
Compact Size
Installs where others wont
Low Air/Gas
Consumption
3.0 scfh at mid range
Approved
for
Natural
Gas
F U N C T I O N A L S P E C I F I C AT I O N S
Inputs
Outputs
Air Consumption
4-20 mA
0.20-1.00 BAR
3-15 psig
0.20-1.80 BAR
3-27 psig
0.40-2.00 BAR
6-30 psig
3.0 scfh (0.11 m3/hr) at mid range
Supply Pressure
100 psig (7.0 BAR) maximum
Note: Supply pressure must be a minimum of 5 psig above maximum output
Flow Capacity
Temperature Limits
explosion-proof housing
RFI/EMI protected
Compact size
P E R F O R M A N C E S P E C I F I C AT I O N S
P H Y S I C A L S P E C I F I C AT I O N S
Accuracy, Hysteresis,
and Repeatability
Deadband
Position Effect
Vibration Effect
Port Sizes
Pneumatic
Electric
Media
Mounting
Materials
Housing
No measurable effect
0.045%/F (0.07%/C) of span
No damage from reversal of normal supply current
(4-20 mA) or from misapplication of up to 60 mA
RFI/EMI Effect
1/4 NPT
1/2 NPT
m20 - 1.5 (ATEX)
Chromate-treated
aluminum with epoxy
paint. NEMA 4X (IP65)
Elastomers
Buna-N
Trim
Ordering
Type 950XP Information
950
Options
Model
Input Signal
A 4-20mA
Output
C
D
E
psig
3-15
3-27
6-30
BAR
0.2-1.0
0.2-1.8
0.4-2.0
4.59
(116.6)
1/2 NPT
port for
conduit
piping
2.07
(52.6)
Standard mounting
bracket for direct,
panel or wall mounting.
.52
(13.2)
.77
1/4 NPT
(19.6)
inlet and
outlet ports,
type both ends
Dimension
IN (mm)
Standard
Unit
Natural Gas
Option
3.62 (92.0)
2" Pipe
2.07 (52.6)
2.22 (56.4)
4.59 (116.6)
4.74 (120.4)
3.37 (85.6)
1 1/2" Pipe
2.50 (63.5)
2.65 (67.3)
1.95
(49.5)
Accessories
Mounting kit for 1.5 or 2 pipe. Kit # 448542-005
1/2 NPT
Port for
Conduit
Piping
Non-Incendive
Class I, Division 2, Groups A, B, C & D
Enclosure Nema 4X(IP 65)
Temp. Code T4 Ta = 70 C
.52
(13.2)
Optional Pipe
Mounting Kit
#448-542-005
Suitable for
Dust Ignition Proof
Class II & III, Division 1, Groups E, F & G Class II & III, Division 2, Groups F & G
Enclosure Nema 4X(IP 65)
Enclosure Nema 4X(IP 65)
Temp. Code T6 Ta = 70 C
Temp. Code T6 Ta = 70 C
Intrinsically Safe
Class I, Division 1, Groups C & D
Class II, Division 1, Groups E, F, & G
Class III, Division 1, Fibers
Enclosure Nema 4X(IP 65)
Rated 4-20 mA, 30 VDC Max.
Temp. Code T4 Ta = 70 C
Entity Parameters
U: (Vmax) = 30 VDC
I: (Imax) = 125 mA
0 3.50
(88.9)
1.00
(25.4)
Optional
1/2 NPT
Sealed Fitting
Natural Gas
Option (E)
Ci = 0 uF
Li = 0 m H
Pi = .7 w
1.64
(41.6)
.84
1.50 (21.3)
(38.1)
C
ATEX Approval
FM06ATEX0018X II 2 G Ex d IIB + H2 T6 Ta = -20 C to +70 C
FM06ATEX0027X II 1 G Ex ia IIB T4 Ta = -40 C to +70 C
FM06ATEX0028X II 3 G Ex nA nL IIC T6 Ta = -40 C to +70
Entity Parameters
Ui (Vmax) = 30 VDC Ci = 0 uF
Li = 0 mH
Ii (Imax) = 125 mA
Pi = .7 W Max.
In/Out Ports
1/4 - 18 NPT
(2) In/(2) Out
.77
(19.6)
A
1.39
(36.4)
.88
(22.4)
Standard
Vent Cover
2.19
(55.6)
2.25
(57.2)
2.81
(71.1)
11/32
(8.6)
Slot
Standard Mounting
Bracket for Direct,
Panel or Wall Mount
Warranty
ControlAir, Inc. products are warranted to be free from defects in materials and
workmanship for a period of eighteen months from the date of sale, provided said
products are used according to ControlAir, Inc. recommended usages. ControlAir,
Inc.'s liability is limited to the repair, purchase price refund, or replacement in kind,
at ControlAir, Inc.'s sole option, of any products proved defective. ControlAir, Inc.
reserves the right to discontinue manufacture of any products or change products
materials, designs or specifications without notice. Note: ControlAir does not
assume responsibility for the selection, use, or maintenance of any product.
Responsibility for the proper selection, use, and maintenance of any ControlAir
product remains solely with the purchaser and end user.
P/N 441-625-022
7-16-07