Hola Edgard, en Julio del ao pasado nos encontramos con una consulta similar a la que planteas, dado esto a
que no encontramos informacin al respecto, gener un DSN y se nos indico que para motores ACERT (C7 / C9)
solo existia la formula que detallo a continuacion:
Leonardo:
I did not find a published blowby specification for the C7, but I found the answer (see below) in another service
request. I hope this answers your question.
D Eckard
1.5xRated Horsepower is the acceptable equation to calculate blowby on the C7 engines. The result of this
equation is Cubic Feet per Hour.
El resultado de esta se debia comparar con experiencias obtenidad de motores nuevos o analisis previos.
Respuesta de Tier II:
I struggle with giving you a good answer to your question. You can see that the publication that we have referred
to were release in 96 and the other in 05. We have requested good blowby data from the design folks, but have
not gotten anything solid to go by. The c9 numbers that are published would most likely represent a TierII engine
and not be representative of a C7 or C9 TierIII. Unfortunately, all you can go by is the formula. Keeping in mind
that it should be used a comparison to blowby readings taken from the engine at sometime prior. I know that you
were looking for something very specific, but we do not have anything to pass on at this time.
Espero que esta informacin te pueda ayudar.
Saludos.
Leonardo Antonucci
Attachments:
Replies:
01/15/2008
Edgard Esquivias
Edgard Esquivias
Community Members
Confidential Yellow
Date:
Buenos dias , alguien conoce alguna informacin sobre los valores Blowby para motores Acert?
Muchas gracias por su ayuda
saludos
https://kn.cat.com/message.cfm?id=11336&parent=197848&type=Broadcast
23/01/2008
Pgina 2 de 3
Edgard
Attachments:
01/15/2008
Ahiro Guzman
Ahiro Guzman
Date:
Sent to:
Original Author
In Reply To:
Caterpillar:
Confidential Yellow
Edgar,
En algn "service request" hice la misma pregunta y me respondieron lo siguiente: "La regla de dedo gordo
es que el blowby sea de 1.3 x HP (cuft/min), es decir para un motor de 200HP tendramos un blowby de 260
cuft/min como aceptable. El rango de inquietud comienza cuando el blowby es de 2 x HP, para el mismo
caso anterior 400 ctft/min."
Espero que sea de alguna utilidad.
Ahir Guzmn
GECOLSA
Attachments:
01/15/2008
Edgard Esquivias
Edgard Esquivias
Date:
Sent to:
Original Author
In Reply To:
Caterpillar:
Confidential Yellow
01/15/2008
01/15/2008
Edgard Esquivias
Edgard Esquivias
Date:
Sent to:
Original Author
In Reply To:
Caterpillar:
Confidential Yellow
https://kn.cat.com/message.cfm?id=11336&parent=197848&type=Broadcast
23/01/2008
Pgina 3 de 3
Caterpillar University
Knowledge Network supported on IE version 5 and above
Caterpillar: Confidential Yellow
Content Owner: Sanchez_Jose@cat.com
Copyright 2001 Caterpillar Inc., All Rights Reserved.
Privacy Statement
https://kn.cat.com/message.cfm?id=11336&parent=197848&type=Broadcast
23/01/2008