TEST REPORT
Needle-Flame Test
Customer
Address
Requestor Name
Product
Test Prime
Date Perform
Report Number
Test Location
ABSTRACT: This report contains the Needle Flame test result for the T8 tube enclosure
provided by NationGate Technology (M) Sdn. Bhd.
Proprietary Information
The information contained in this document is the property of QAV Technologies Sdn. Bhd.
Except as specifically authorized in writing by Nation Gate Technology (M) Sdn. Bhd., the
holder of this document: (1) shall keep all information contained herein confidential and shall
protect same in whole or in part from disclosure and dissemination to all third parties and (2)
shall use same for operating and maintenance purposes only.
107-000-002-FR-0101
Page 1 of 7
1.0
Test Summary:
8 units of T8 tube enclosure were subjected to needle flame test for evaluation the
resistance of the sample against flame.
2.0
Test Objective:
The test objective was to determine the resistance of the sample against flame.
107-000-002-FR-0101
Page 2 of 7
107-000-002-FR-0101
Page 3 of 7
107-000-002-FR-0101
Page 4 of 7
Test Location
Test Location
Lab Temperature
Lab Humidity
107-000-002-FR-0101
Page 5 of 7
5.0
Test Equipment
Test Setup
107-000-002-FR-0101
Page 6 of 7
7.0
Result
T8 Tube Enclosure
A SB-2641
B LD7700F
C 1303-15
D LD7650
E ML3110
F ML3110 (1+30%)
G 1250
H ML3110 (1+50%)
8.0
Side
Frosted
Frosted
Clear
Frosted
Frosted
Frosted
Clear
Frosted
Table 2: Result
Result
Pass
Fail
Fail
Fail
Pass
Pass
Fail
Pass
Conclusion
A,E,F and H of T8 tube enclosure pass the needle flame test while the
B,C,D and G of T8 tube enclosure fail the needle flame test because there are
burning drop and it ignite the tissue paper after application of needle-flame.
..
Janice Tan
Project Engineer
107-000-002-FR-0101
Approved Signatory
...
Page 7 of 7