You are on page 1of 22

VACUUM PUMPS P6010

P6010 Pi48-3X1
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared toconventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
Low feed pressure that ensures high
realiabilityeven in case of pressure drops
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6570
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.22
1.62
0.30
2.0
0.40
2.54

0
5.0
5.6
5.7

Vacuum flow (Nl/s) at different vacuum levels (-kPa)


20
30
40
50
60
70
80
1.5
0.90
0.55
0.45
0.26
0.07

1.8
1.1
0.65
0.50
0.35
0.25
0.10
2.1
1.5
1.10
0.66
0.36
0.26
0.080

90

Max vacuum
-kPa
73
90
86

Evacuation time (s/l) to reach different vacuum levels (-kPa)


20
30
40
50
60
70
80
0.080
0.090
0.30
0.50
0.80
1.7

0.060
0.12
0.30
0.45
0.70
1.0
1.6
0.055
0.11
0.18
0.29
0.59
0.90
1.7

90

4.0

Max vacuum
-kPa
73
90
86

140
3.7

Max pressure
kPa
140

10
2.0
2.5
2.5

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.22
1.62
0.30
2.0
0.40
2.54

10
0.025
0.020
0.020

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0.60
3.55
0.40 MPa

0.30 MPa

0
9.5

20
6.5

Blow flow (Nl/s) at different pressure levels (kPa)


40
60
70
80
90
100
110
120
6.0 5.3 4.7 4.6 4.6
4.6
4.5
4.3
0.40 MPa

0.22 MPa

0.30 MPa

0.60 MPa

0.22 MPa

4.0

130
4.0

10

3.5
5

2.5

2.0

Nl/s

Nl/s

3.0
4

1.5
2
1.0
1
0

0.5

10 20 30 40 50 60 70 80 90

0.0
10 20 30 40 50 60 70 80 90

2
0

20 40 60 70 80 90 100 110 120 130 140

-kPa

Vacuum flow

96

Evacuation time

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


a
COAX cartridge module Pi48-3X1
b
COAX cartridge module Pi48-3X1, non-return valve

P6010 Code
AJ
AN

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x G3/4"
Connections 2x G3/4", silencer 3/4"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"
Connections 2x 3/4" NPSF
Connections 2x 3/4" NPSF, silencer 3/4"

P6010 Code
51
52
53
54
55
56
57
58

Example
P6010 Pi48-3X1, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AJ 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

97

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Pi48-3X2
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared toconventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
Low feed pressure that ensures high
realiabilityeven in case of pressure drops
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6570
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.22
3.24
0.30
4.0
0.40
5.08

Vacuum flow (Nl/s) at different vacuum levels (-kPa)


20
30
40
50
60
70
3.0
1.8
1.1
0.90
0.52
0.14
3.6
2.2
1.3
1.0
0.70
0.50
4.2
3.0
2.2
1.3
0.7
0.52

0
10.0
11.2
11.4

10
4.0
5.0
5.0

10
0.013
0.010
0.010

Evacuation time (s/l) to reach


20
30
40
0.040
0.045
0.15
0.030
0.060
0.13
0.028
0.055
0.090

80

0.20
0.16

90

Max vacuum
-kPa
73
90
86

90

2.0

Max vacuum
-kPa
73
90
86

140
7.4

Max pressure
kPa
140

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.22
3.24
0.30
4.0
0.40
5.08

different
50
0.25
0.23
0.15

vacuum levels (-kPa)


60
70
80
0.40
0.85

0.35
0.50
0.80
0.30
0.45
0.85

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0
0.60
7.1
19.0
0.40 MPa

0.30 MPa

20
13.0

Blow flow (Nl/s) at different pressure levels (kPa)


40
60
70 80 90 100 110
120
12.0 10.6 9.4 9.2 9.2 9.2
9.0
8.6
0.40 MPa

0.22 MPa

0.30 MPa

0.22 MPa

0.60 MPa

2.0

12

130
8.0

20

10
1.5

15

Nl/s

Nl/s

8
1.0

10

4
0.5

10

20

30

40

50

60

70

80

90

0.0
10

20

30

40

50

60

70

80

90

5
0

20 40 60 70 80 90 100 110 120 130 140

-kPa

Vacuum flow

98

Evacuation time

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


a
COAX cartridge module Pi48-3X2
b
COAX cartridge module Pi48-3X2, non-return valve

P6010 Code
AK
AO

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x G3/4"
Connections 2x G3/4", silencer 3/4"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"
Connections 2x 3/4" NPSF
Connections 2x 3/4" NPSF, silencer 3/4"

P6010 Code
51
52
53
54
55
56
57
58

Example
P6010 Pi48-3X2, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AK 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

99

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Pi48-3X3
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared toconventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
Low feed pressure that ensures high
realiabilityeven in case of pressure drops
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6570
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.22
4.86
0.30
6.0
0.40
7.62

Vacuum flow (Nl/s) at


10
20
30
6.0
4.5
2.7
7.5
5.4
3.3
7.5
6.3
4.5

0
15.0
16.8
17.1

different vacuum levels


40
50
60
1.7
1.4
0.78
2.0
1.5
1.1
3.3
2.0
1.1

(-kPa)
70
0.21
0.75
0.78

80

0.30
0.24

90

Max vacuum
-kPa
73
90
86

Evacuation time (s/l) to reach different vacuum levels (-kPa)


20
30
40
50
60
70
80
0.027
0.030
0.10
0.17
0.27
0.57

0.020
0.040
0.083
0.15
0.23
0.33
0.53
0.018
0.037
0.060
0.097
0.20
0.30
0.57

90

1.3

Max vacuum
-kPa
73
90
86

140
11.1

Max pressure
kPa
140

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.22
4.86
0.30
6.0
0.40
7.62

10
0.008
0.007
0.007

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0.60
10.65
0.40 MPa

0.30 MPa

Blow flow (Nl/s) at different pressure levels (kPa)


20
40
60
70
80
90
100 110 120
19.5 18.0 15.9 14.1 13.8 13.8 13.8 13.5 12.9

0
29

0.40 MPa

0.22 MPa

0.30 MPa

0.22 MPa

0.60 MPa

1.5

20

30

1.2

15

130
12.0

25

Nl/s

Nl/s

0.9

10

20

0.6

15

0.3

0.0

10

20

30

40

50

60

70

80

90

10

20

30

40

50

60

70

80

90

10

20 40 60 70 80 90 100 110 120 130 140

-kPa

Vacuum flow

100

Evacuation time

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


a
COAX cartridge module Pi48-3X3
b
COAX cartridge module Pi48-3X3, non-return valve

P6010 Code
AL
AP

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"

P6010 Code
51
52
55
56

Example
P6010 Pi48-3X3, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AL 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

101

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Pi48-3X4
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared toconventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
Low feed pressure that ensures high
realiabilityeven in case of pressure drops
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6570
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.22
6.48
0.30
8.0
0.40
10.16

Vacuum flow (Nl/s) at different vacuum levels (-kPa)


10
20
30
40
50
60
70
8.0
6.0
3.6
2.2
1.8
1.0
0.28
10.0
7.2
4.4
2.6
2.0
1.4
1.0
10.0
8.4
6.0
4.4
2.6
1.4
1.0

0
20.0
22.4
22.8

80

0.40
0.32

90

Max vacuum
-kPa
73
90
86

Evacuation time (s/l) to reach different vacuum levels (-kPa)


20
30
40
50
60
70
80
0.020
0.023
0.075
0.13
0.20
0.43

0.015
0.030
0.063
0.11
0.18
0.25
0.40
0.014
0.028
0.045
0.073
0.15
0.23
0.43

90

1.0

Max vacuum
-kPa
73
90
86

140
14.8

Max pressure
kPa
140

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.22
6.48
0.30
8.0
0.40
10.16

10
0.006
0.005
0.005

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0.60
14.2
0.40 MPa

0.30 MPa

0
38

20
26

Blow flow (Nl/s) at different pressure levels (kPa)


40
60
70
80
90
100 110 120
24.0 21.2 18.8 18.4 18.4 18.4 18.0 17.2
0.40 MPa

0.22 MPa

0.30 MPa

0.22 MPa

130
16.0

0.60 MPa

25

1.0

40

20

0.8

35

15

0.6

10

0.4

Nl/s

Nl/s

30

25

20
0.2

15
0.0

10

20

30

40

50

60

70

80

90

10

20

30

40

50

60

70

80

90

10

20 40 60 70 80 90 100 110 120 130 140

-kPa

Vacuum flow

102

Evacuation time

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX cartridge modules


a
COAX cartridge module Pi48-3X4
b
COAX cartridge module Pi48-3X4, non-return valve

P6010 Code
AM
AQ

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"

P6010 Code
51
52
55
56

Example
P6010 Pi48-3X4, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AM 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

103

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Si32-3X1
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared to conventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
High flow - suitable for handling of porous objects
and in case of leakage
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6065
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.40
1.25
0.50
1.5
0.60
1.75

0
5.0
5.7
6.0

10
2.9
3.3
3.5

Vacuum flow
20
1.9
2.2
2.6

(Nl/s) at different vacuum levels


30
40
50
1.2
0.80
0.40
1.4
0.85
0.62
1.7
0.90
0.60

(-kPa)
60
0.10
0.35
0.50

70

0.18
0.35

Max vacuum
-kPa
60
70
75

70

1.0
0.80

Max vacuum
-kPa
60
70
75

80
1.8

Max pressure
kPa
80

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.40
1.25
0.50
1.5
0.60
1.75

10
0.030
0.020
0.020

Evacuation time (s/l) to reach different vacuum levels (-kPa)


20
30
40
50
60
0.070
0.14
0.24
0.42
1.0
0.060
0.11
0.21
0.35
0.60
0.050
0.10
0.18
0.33
0.53

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0.60
1.75
0.60 MPa

0.50 MPa

0
7.8

10
5.4

Blow flow (Nl/s) at different pressure levels (kPa)


20
30
40
50
60
70
4.6
3.8
3.3
3.1
2.7
2.3
0.60 MPa

0.40 MPa

0.50 MPa

0.60 MPa

0.40 MPa

1.0

8
7

0.8

6
0.6

Nl/s

Nl/s

s/l

5
4

0.4

2
3
0.2

2
0.0

10

20

30

40

-kPa

Vacuum flow

104

50

60

70

10

20

30

40

50

60

70

-kPa

Evacuation time

80

90

10

20

30

40

50

60

70

80

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


a
COAX cartridge module Si32-3X1
b
COAX cartridge module Si32-3X1, non-return valve

P6010 Code
AB
AF

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x G3/4"
Connections 2x G3/4", silencer 3/4"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"
Connections 2x 3/4" NPSF
Connections 2x 3/4" NPSF, silencer 3/4"

P6010 Code
51
52
53
54
55
56
57
58

Example
P6010 Si32-3X1, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AB 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

105

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Si32-3X2
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared to conventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
High flow - suitable for handling of porous objects
and in case of leakage
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6065
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.40
2.5
0.50
3.0
0.60
3.5

Vacuum flow (Nl/s) at different vacuum levels (-kPa)


20
30
40
50
60
70
3.8
2.4
1.6
0.80
0.20

4.4
2.8
1.7
1.2
0.70
0.36
5.2
3.4
1.8
1.2
1.0
0.70

0
10.0
11.4
12.0

10
5.8
6.6
7.0

10
0.015
0.010
0.010

Evacuation
20
0.035
0.030
0.025

80

90

Max vacuum
-kPa
60
70
75

90

Max vacuum
-kPa
60
70
75

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.40
2.5
0.50
3.0
0.60
3.5

time (s/l) to reach different vacuum levels (-kPa)


30
40
50
60
70
80
0.070
0.12
0.21
0.50

0.055
0.11
0.18
0.30
0.50

0.050
0.090
0.17
0.27
0.40

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0
0.60
3.5
15.5
0.60 MPa

0.50 MPa

10
10.8

Blow flow (Nl/s) at different pressure levels (kPa)


20
30
40
50
60
70
9.2
7.6
6.6
6.2
5.4
4.6
0.60 MPa

0.40 MPa

12

0.5

10

0.4

0.50 MPa

0.40 MPa

Max pressure
kPa
80

80
3.6

0.60 MPa
20

15
8

Nl/s

Nl/s

0.3

10

0.2

4
5

0.1

0.0

10

20

30

40

50

60

70

80

90

10

20

30

40

50

60

70

80

90

10

20

30

40

50

60

70

80

-kPa

Vacuum flow

106

Evacuation time

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX cartridge modules


a
COAX cartridge module Si32-3X2
b
COAX cartridge module Si32-3X2, non-return valve

P6010 Code
AC
AG

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x G3/4"
Connections 2x G3/4", silencer 3/4"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"
Connections 2x 3/4" NPSF
Connections 2x 3/4" NPSF, silencer 3/4"

P6010 Code
51
52
53
54
55
56
57
58

Example
P6010 Si32-3X2, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AC 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

107

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Si32-3X3
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared to conventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
High flow - suitable for handling of porous objects
and in case of leakage
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6065
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.40
3.75
0.50
4.5
0.60
5.25

0
15.0
17.1
18.0

Vacuum flow
10
20
8.7
5.7
9.9
6.6
10.5
7.8

(Nl/s)
30
3.6
4.2
5.1

at different vacuum levels (-kPa)


40
50
60
70
2.4
1.2
0.30

2.6
1.8
1.1
0.54
2.7
1.8
1.5
1.1

80

Max vacuum
-kPa
60
70
75

90

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.40
3.75
0.50
4.5
0.60
5.25

10
0.010
0.007
0.007

Evacuation
20
0.023
0.020
0.017

time (s/l) to reach different vacuum levels (-kPa)


30
40
50
60
70
0.047
0.080
0.14
0.33

0.037
0.070
0.12
0.20
0.33
0.033
0.060
0.11
0.18
0.27

80

90

Max vacuum
-kPa
60
70
75

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0.60
5.25
0.60 MPa

0.50 MPa

0
23.3

Blow flow (Nl/s) at different pressure levels (kPa)


10
20
30
40
50
60
16.2
13.8
11.4
9.9
9.3
8.1
0.60 MPa

0.40 MPa

0.50 MPa

Max pressure
kPa
80

80
5.4

0.60 MPa

0.40 MPa

0.35

20

70
6.9

25

0.30

15

0.20

Nl/s

s/l
Nl/s

20

0.25

10

15

0.15
0.10

10

5
0.05

0.00

10

20

30

40

50

-kPa

Vacuum flow

108

60

70

80

90

10

20

30

40

50

60

-kPa

Evacuation time

70

80

90

10

20

30

40

50

60

70

80

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX cartridge modules


a
COAX cartridge module Si32-3X3
b
COAX cartridge module Si32-3X3, non-return valve

P6010 Code
AD
AH

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"

P6010 Code
51
52
55
56

Example
P6010 Si32-3X3, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AD 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

109

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 Si32-3X4
X Patented COAX technology
X Substationally lower air consumption as
X
X
X
X
X

compared to conventional ejectors


Modular design
Available with multiple connection alternatives
Low noise level
High flow - suitable for handling of porous objects
and in case of leakage
Short evacuation time

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
6065
-1080
17001800
Al, PA, NBR, SS, TPE

VACUUM FLOW
Feed pressure Air consumption
MPa
Nl/s
0.40
5.0
0.50
6.0
0.60
7.0

0
20.0
22.8
24.0

Vacuum flow (Nl/s) at different vacuum levels (-kPa)


10
20
30
40
50
60
70
11.6
7.6
4.8
3.2
1.6
0.40

13.2
8.8
5.6
3.4
2.4
1.4
0.72
14.0
10.4
6.8
3.6
2.4
2.0
1.4

10
0.008
0.005
0.005

Evacuation
20
0.018
0.015
0.013

80

90

Max vacuum
-kPa
60
70
75

90

Max vacuum
-kPa
60
70
75

80
7.2

Max pressure
kPa
80

40

60

EVACUATION TIME
Feed pressure Air consumption
MPa
Nl/s
0.40
5.0
0.50
6.0
0.60
7.0

time (s/l)
30
0.035
0.028
0.025

to reach different vacuum levels (-kPa)


40
50
60
70
0.060
0.11
0.25

0.053
0.088
0.15
0.25
0.045
0.083
0.13
0.20

80

BLOW FLOW
Feed pressure Air consumption
MPa
Nl/s
0.60
7.0
0.60 MPa

0.50 MPa

0
31

10
21.6

Blow flow (Nl/s) at different pressure levels (kPa)


20
30
40
50
60
18.4
15.2
13.2
12.4
10.8
0.60 MPa

0.40 MPa

25

0.25

20

0.20

15

0.15

0.50 MPa

70
9.2

0.60 MPa

0.40 MPa

35

30

Nl/s

Nl/s

s/l

25

20

0.10

10

15
0.05

10
0.00

10

20

30

40

50

-kPa

Vacuum flow

110

60

70

80

90

10

20

30

40

50

60

-kPa

Evacuation time

70

80

90

10

20

30

50

70

80

Blow flow

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


a
COAX cartridge module Si32-3X4
b
COAX cartridge module Si32-3X4, non-return valve

P6010 Code
AE
AI

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate G thread connections, Cover plate, plain
Cover plate NPSF thread connections, Cover plate, plain

P6010 Code
LA
LJ

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"

P6010 Code
51
52
55
56

Example
P6010 Si32-3X4, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1"

Ordering number
P6010 AE 01 LA 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 250 kPa
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112533
0112532

111

Vacuum pumps
P6010

ORDERING INFORMATION

VACUUM PUMPS P6010


P6010 AVM
X Patented COAX technology
X Suitable for vacuum systems using numerous
X
X
X
X

X
X

large suction cups


Valves for ON/OFF of vacuum and for blow-off
Adjustment valve for controlling the blow-off flow
Two vacuum switches with signal output.
Automatic energy-saving function -can be
switched off in applications where leakage is
present
Onesingle M12 8-pin electric connection that
facilitatesinstallation
PNP or NPNoutput selectable.

Supplied with a vacuum gauge.


TECHNICAL DATA
Description
Feed pressure, max.
Noise level
Material
Temperature range
Weight
Voltage
Ripple, max.
Current consumption
Safety classification
Current, max. output load
Display

Unit
MPa
dBA

Value
0.7
5070
Al, PA, NBR, SS, PMMA, ABS, TPE
050
20002100
24 (2230)
1Vrms
110
IP65
100
LED indicators

C
g
VDC
Vp
mA
mA

TECHNICAL DATA, SPECIFIC


Description
Function, on/off
Signal range

Unit

-kPa

Value
LC, LL
NO
30/50

LD, LM
NO
30/70

LE, LN
NO
50/70

LF, LO
NC
30/50

LG, LP
NC
30/70

LH, LQ
NC
50/70

PERFORMANCE TABLES
Depending upon choice of COAXCartridge, applicable performance data of the P6010 AVM can be found in
the tables for vacuum flow and evacuation time for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.

ORDERING INFORMATION
1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


COAX cartridge module Pi48-3X1, non-return valve
COAX cartridge module Pi48-3X2, non-return valve
COAX cartridge module Pi48-3X3, non-return valve
COAX cartridge module Pi48-3X4, non-return valve
COAX cartridge module Si32-3X1, non-return valve
COAX cartridge module Si32-3X2, non-return valve
COAX cartridge module Si32-3X3, non-return valve
COAX cartridge module Si32-3X4, non-return valve

P6010 Code
AN
AO
AP
AQ
AF
AG
AH
AI

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

112

Specifications subject to change without notice.

VACUUM PUMPS P6010

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"
Example
P6010 Si32-3X2, Mounting T-slot, Cover plate with AVM NO 30/50 function and G-threads, Connections 2x G1"
and silencer 1"

P6010 Code
LC
LD
LE
LF
LG
LH
LL
LM
LN
LO
LP
LQ
P6010 Code
51
52
55
56
Ordering number
P6010 AG 01 LC 52

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Manometer 1 MPa
Cable 2m 0.25 x 7 PUR with electrical connector M12 8-pin

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112532
0110238

113

Vacuum pumps
P6010

4. Cover plates
Function AVM NO 30/50, Cover plate G thread connections
Function AVM NO 30/70, Cover plate G thread connections
Function AVM NO 50/70, Cover plate G thread connections
Function AVM NC 30/50, Cover plate G thread connections
Function AVM NC 30/70, Cover plate G thread connections
Function AVM NC 50/70, Cover plate G thread connections
Function AVM NO 30/50, Cover plate NPSF thread connections
Function AVM NO 30/70, Cover plate NPSF thread connections
Function AVM NO 50/70, Cover plate NPSF thread connections
Function AVM NC 30/50, Cover plate NPSF thread connections
Function AVM NC 30/70, Cover plate NPSF thread connections
Function AVM NC 50/70, Cover plate NPSF thread connections
NO = Normally open valve for vacuum on/off, NC = Normally closed valve for vacuum on/off

VACUUM PUMPS P6010


P6010 PCC
X Patented COAXtechnology
X Programmable for constant vacuum level or blowX
X
X
X

pressure level in the system


Quick adjustment
Easy to install in control systems
Low power consumption, 24 VDC/120 mA
Integrated analogue vacuum or blow-pressure
sensor

Supplied with a vacuum gauge.

TECHNICAL DATA
Description
Unit
Value
Feed pressure, max.
MPa
1.0
Noise level
dBA
5070
Temperature range
C
350
Weight
g
21002200
Material
Al, PA, NBR, SS, AiSi302
Voltage supply
VDC
24 (21.826.4)
Current consumption
mA
<120
Voltage signal, input/output
VDC
010
Scale factor signal out, vacuum
-kPa
0100
Scale factor signal in, vacuum
-kPa
090
Scale factor signal out, blow
MPa
00.2
Safety classification
IP65
The design of PCC requires that the inlet pressure is 0.1 MPa higher than the outlet pressure.

PERFORMANCE TABLES
Depending upon choice of COAX Cartridge, applicable performance data of the P6010 PCC can be found in
the tables for vacuum flow, evacuation time and blow flow for models P6010 Pi48-3x1 to x4 as well as for Si323x1 to x4.
ORDERING INFORMATION
1. Housing
Housing

P6010 Code
P6010

2. COAX catridge modules


COAX cartridge module Pi48-3X1
COAX cartridge module Pi48-3X2
COAX cartridge module Pi48-3X3
COAX cartridge module Pi48-3X4
COAX cartridge module Si32-3X1
COAX cartridge module Si32-3X2
COAX cartridge module Si32-3X3
COAX cartridge module Si32-3X4

P6010 Code
AJ
AK
AL
AM
AB
AC
AD
AE

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Function PCC Vacuum, Cover plate G thread connections
Function PCC Blow, Cover plate G-thread connections
Function PCC Blow, Cover plate NPSF thread connections
Function PCC Vacuum, Cover plate NPSF thread connections

P6010 Code
LB
LR
LS
LT

5. Connections for vacuum and exhaust


Connections 2x G1"
Connections 2x G1", silencer 1"
Connections 2x 1" NPSF
Connections 2x 1" NPSF, silencer 1"

P6010 Code
51
52
55
56

114

Specifications subject to change without notice.

VACUUM PUMPS P6010


Ordering number
P6010 AC 01 LB 52

Vacuum pumps
P6010

Example
P6010 Si32-3X2, Mounting T-slot, Cover plate with PCC vacuum function and G-threads, Connections 2x G1"
and silencer 1"

ORDERING INFORMATION, ACCESSORIES


Description
Silencer G1"
Silencer 1" NPSF
Cable L=3m, M16 8-pin, angled
Cable, L=3m, M16 8-pin, straight
Manometer 1 MPa

Specifications subject to change without notice.

Art. No.
0112499
0113003
0112395
0112393
0112532

115

VACUUM PUMPS P6010


P6010 CLASSIC
X Patented COAX technology
X Connections can be made on the long side of the

ejector
X Retro-compatible withPIABs Classic model in
regard to mounting
Supplied with a vacuum gauge.

TECHNICAL DATA
Description
Feed pressure, max
Noise level
Temperature range
Weight
Material

Unit
MPa
dBA
C
g

Value
0.7
5065
-1080
17001800
Al, PA, NBR, SS, TPE

PERFORMANCE TABLES
Depending upon choice of COAX Cartridge, performance data of the P6010 Classic can be found in the tables
for vacuum flow, evacuation time and blow flow for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.

116

Specifications subject to change without notice.

VACUUM PUMPS P6010


1. Housing
Housing

P6010 Code
P6010

2. COAX cartridge modules


a
COAX cartridge module Pi48-3X1
a
COAX cartridge module Pi48-3X2
a
COAX cartridge module Pi48-3X3
a
COAX cartridge module Pi48-3X4
b
COAX cartridge module Pi48-3X1, non-return valve
b
COAX cartridge module Pi48-3X2, non-return valve
b
COAX cartridge module Pi48-3X3, non-return valve
b
COAX cartridge module Pi48-3X4, non-return valve
a
COAX cartridge module Si32-3X1
a
COAX cartridge module Si32-3X2
a
COAX cartridge module Si32-3X3
a
COAX cartridge module Si32-3X4
b
COAX cartridge module Si32-3X1, non-return valve
b
COAX cartridge module Si32-3X2, non-return valve
b
COAX cartridge module Si32-3X3, non-return valve
b
COAX cartridge module Si32-3X4, non-return valve

P6010 Code
AJ
AK
AL
AM
AN
AO
AP
AQ
AB
AC
AD
AE
AF
AG
AH
AI

3. Mounting
Mounting T-slot, Cover plate with PIAB label

P6010 Code
01

4. Cover plates
Cover plate Classic G thread connections, Cover plate plain
Cover plate Classic NPSF thread connections, Cover plate plain

P6010 Code
LI
LK

5. Connections for vacuum and exhaust


Connections 2x G3/4"
Connections 2x G3/4", silencer 3/4"
Connections 2x 3/4" NPSF
Connections 2x 3/4" NPSF, silencer 3/4"

P6010 Code
53
54
57
58

Example
P6010 Pi48-3X4, Mounting T-slot, Cover plate Classic G-threads, Connections 2x G3/4" and silencer 3/4"

Vacuum pumps
P6010

ORDERING INFORMATION

Ordering number
P6010 AM 01 LI 54

ORDERING INFORMATION, ACCESSORIES


Description
Manometer 250 kPa
Manometer 1 MPa
Silencer G3/4

Specifications subject to change without notice.

Art. No.
0112533
0112532
3216002

117

You might also like