Fach utilization

===============
---------------------------------------------------------------------------------------------=((VS.CRNCIubBytesFACH.Tx (byte)/(<measrument periond in secs))/VS.CRNC.IUB.FACH
.Bandwidth (byte/s))*100
---------------------------------------------------------------------------------------------As per Hedex:
PCH usage = VS.UTRAN.AttPaging1/(<SP> x 60 x 5/0.01)
-Usage of an FACH carried on a non-standard SCCPCH = VS.CRNCIubBytesFACH.Tx x 8/
[(60 x <SP> x 168 x 1/0.01) x VS.PCH.Bandwidth.UsageRate x 6/7 + [60 x <SP> x 36
0 x 1/0.01) x (1- VS.PCH.Bandwidth.UsageRate x 6/7)]
-Usage of an FACH carried on a standard SCCPCH = VS.CRNCIubBytesFACH.Tx x 8/(60
x <SP> x 360 x 1/0.01)
SP indicates the measurement period in seconds.
---------------------------------------------------------------------------------------------Can Use these formulas to check FACH and PCH Utilization
FACH Utilization NC.IUB.FACH.Bandwidth
PCH Utilization NC.IUB.PCH.Bandwidth

100*{VS.CRNCIubBytesFACH.Tx/measurement duration}/ VS.CR


100*{VS.CRNC.IubBytesPCH.tx/measurement duration}/ VS.CR

VS.RRC.Paging1.Loss.PCHCong.Cell shows Paging loss due to PCH congestion, so PCH


congestion can be reflected.
FACH congestion is shown by these counters.
VS.FACH.DCCH.CONG.TIME - Congestion Duration of DCCHs Carried over FACHs for Cel
l
VS.FACH.DTCH.CONG.TIME - Congestion Duration of DTCHs Carried over FACHs for Cel
l
---------------------------------------------------------------------------------------------No of Users
===============
VS.CellFACHUEs
VS.CellDCHUEs VS.CellPCHUEs
---------------------------------------------------------------------------------------------E//
====
average number of users in Cell Fach=(pmSumFachPsIntRabEstablish / pmSamplesFach
PsIntRabEstablish)