You are on page 1of 4

REF

ESD/DOC/20
PAGE
Page 1 0f 1
REV.No.
0
REV.DATE
6/30/2015
Approved by: MG
ODY Voltage level :

Earthing Materials estimation

B FOURESS (P) LIMITED


Prepared by : GSS
Project No: 398
Project Name: Lower Aleo

No of
No of
No.of Aux
Units/Gen Transform
Trafo
eartor
er
2

Data to be filled

I.MS flat calculations


A
PH

Length
19.5

ODY

34.5

Lenght
B

Inter conection
Betn PH & Ody

PH Riser

Width
16.5
18

Crane level
Turbine
Generator
Control panel
swith gear panel
NGT Panel
T Opu Motors
Gen LOS Motors
CW motors
Drainage motors
Dewatering
Motors
Lighting panel
Marshling box

1.5

14
12
24
13
Total

231
234
432
448.5
1345.5

No of
interconct
ion

27

Lenght

Intervel
1.5

81

No of
No of riser units

Total length

23

46

28

28

15

30

15

30

7
7

2
2

2
2

28
28

28

28

14

14

15
7

0
4

30

0
4
16

0
8
32

332
D

ODY Riser

Riser calculations

No of equipments

Sl no

6 Sqmm
Flexible Grren No of
color cable
Lugs

ODY

33KV
Lengh
34.5

CT(1 set) PT(1 set) Isolator


2
2
2

Width
18
Power
Auxilary
transform transform
er
er
Breaker
2
2
2

No of
riser
conection Lenght
24
432

Grand Total MS Flat


II

2190.5 Mts
Orderd qty
2409.55

Copper flats 50 X 6

Sl no
Hight
Length from
Bottom of the
equipments to
Earth pit
Total

No
No Power Auxiliry
Transform Transform
er
er
Total
2
1
7
2

3
17

3
5

22

Orderd qty

24.2

III

Copper flats 50 X 3

Sl no
Hight
Length from
Bottom of the
equipments to
Earth pit
Total

No of LA
No of LA in Line
in tr/r side side
3
3
3.1
7.5

3
12.3

3
25.5

No of
Supporting
Insulator
33.8

Total

37.8

Orderd qty

Order qty
37.18

41.58

IV.GI Flat Calculation 50 X 3


Lenght
A

Power cable tray

T Opu Motors

No of
Motors
/Riser
2

Gen LOS Motors


CW motors

2
2

Rorot Jacking
system

Drainage motors

Length
3

1.5
1.5

3
3

1.5

Dewatering
Motors

1.5

Control panel line


up

1.5

Swicth gear Panel


line
NGT Panel
Lighting panel

2
2
1

ODY Riser

1.5
1.5
1.5
Total
Riser calculations

No of equipments

Sl no
No of equipments
Hight
Length from
Bottom of the
equipments to GI
Grid flat.

Length
1.5

ODY

3
3
1.5
25.5
33KV
Lengh
34.5

CT(1 set) PT(1 set) Isolator

Width
18

Power
Auxilary
transform transform
er
er
Breaker

No of two No of four
pole
pole
structure structure

3
3.1

3
3.1

1
2.8

2
4

2
4

1
4

1
2

1
2

2.5
16.8
Total

2.5
16.8

2.5
5.3
106.4

2.5
13

2.5
13

2.5
6.5

2.5
11

2.5
22

Total

30
161.9

Inter conection of
Earth pit
Grand Total

V.Bolts & nuts for GI Flat


Qty
161.9
VI

Std length No of Bolts & nuts


2.5
64.76
64.76

Order qty
in nos
71.236

Braided Copper cable


Isolator
Main
Marshling
No of equipments CT(1 set) PT(1 set) box
3
3
1

Isolator
Earth
Switch
Marshling
box
Breaker
1
1

total no of
equipments
9

Braided
Copper
cable
4.5

No of
Coper
Spike for
PH
2

ESD/DOC/20
Page 1 0f 1

6/30/2015
ved by: MG
33kV

No of GI
Spike for
ODY
6

You might also like