Welded connection

Flange plate
Width =

250 mm

thickness =

25 mm

Height =

575 mm

thickness =

25 mm

Web plate

Moment of Inertia

2390351563 mm4

Section modulus

6460410 mm3

HE 700A section modulus

6241000 mm3

Direct Shear

200 kN

Bending moment

700 kN.m

Side view

Top plan

500
300
length of flange weld

850 mm

Depth of web weld

500 mm

Length of weld (One side of web weld considered), L

2200 mm

Moment of Inertia of weld, Ix

Direct shear per mm, Fs

0.09090909 kN/mm

Due to moment, Ft

1.065 kN/mm

Resultant shear, Fr

1.069 kN/mm

Strength of 10mm fillet weld (S275)

1.54 kN/mm

Hence provide minimum size of fillet weld

243146667 mm3

10 mm

740

OK

250