PFA Ultrasonic flowmeter fits flow measuremnt of extremely small amount of flow.
Low cost version letting it have no display function.
Various kinds of the settings can be made by such specialized software as shwon in option.
Due to the load of RS-485 communicating function up to 16 units can be communicated.
Caution
We cannot be responsible for the failure caused by the use of the penetrating chemicals on the materials of the wetted part of this product.
FAXOK!
Type selection
Std.
USF200S
Fluids
Option
Units
Max. flow
Flow indicator
Max.
A
1
9
mL/min
Pure water
For specif. fluid1
Material
Std.
Measuring range
Pipe size
G08
0300mL/min
G10
55000mL/min
NEW PFA
1 1: For specif. items specify them at end of Type selection in order. For details, consult us with your specification.
2: Refer to a table of measuring range below.
2
Measuring range shows ones equivalent to pure water.
Structural drawing
Detector
92
18
Electronics part
2-1/4or 3/8
4-4.5
26
USF200S
FLOW
17
36
17
(50)
48
270
170
112
(50)
91
2-4.5
Power supply
2-4.5 through hole
1.
2.
Since the tube length is appropriately designed according to each type of flowmeter, please use it without cutting.
4-20mA 4-20mA output
3.
4.
5. 1 Open collector output 1
6. 2 Open collector output 2
7.COM COM to open collector output
RS-485
10Jumper pin 1(Reset at zero point)
8.
2Jumper pin 2(Integrating reset)
3Jumper pin 3(Terminating resistance)
9.
POWER
BLACK
RED
ERROR
120
208
2015 Vol.1
78 9
10
BC D E
3 45 6
Ultrasonic Flowmeter
PFA
RS-485 (16
35
For Chemicals
. 35mmDIN
PFP100N
Note) 1. 35mm width DIN rail mountable (Model number PFP-100N made by Omron recommended)
C
Performance
Types
USF200S-G08
USF200S-G10
Pure water/Chemicals
Fluid
55000mL/min
0.1mL/min
1mL/min
1 of 300mL/min
1 of 5000mL/min
Max. 80
050
0-50(No dewing)
Ambient temperature
Detecting method
Contact
DC4-20mA
Output 4-20mA
32000mL
Totalized Flow range:Arbitrary setting can be made up to 32000mL at upper limit(20mA)
Rated output
:Max
35VVoL1.3VImpressed voltage:Max. 35VVoL1.3V
:Max
100mA Sink current:Max. 100mA
:2 11 LOWOutput port:2-port. 1 output per portActive LOW
1
Instant frequency output
Output port 1
1
Integrating pulse output
Output port 1
:103000HzFS1003000Hz
Frequency range:103000Hzselectable between100 and 3000Hz for FS
:FS FS Available range (flow rate based):FS is determined based on FS value
12
Comparative output
Output port 12
:1 2
Setup1: Instantaneous flow/Totalized flow, Setup2: selectable between upper and lower limit.
: mL/min mL Trip-point setup:Instantaneous flow mL/minTotalized flow mL
032000 1Setup range: 032000Setting STP: 1
Fail
2
Fail output(Output port 2)
:1 Flow rate setup per pulse:Value selectable for totalized flow per pulse
G08:0.13200.0mL 0.1mLG08:0.13200.0mLSetting STP: 0.1mL
G10:132000mL 1mLG10:132000mLSetting STP: 1mL
:1800msec 1msecPulse width setup:1800msecSetting STP: 1msec
RS-485
Communicating function
Power supply voltage
DC24V 10
Power consumption
Heat resistance
Max
80
NEW PFA
3m3m(coaxial cable shielded with Teflon)
Cable length
Pipe size
Terminal connection
Installation attitude
1
Power supply
DC 24V
.,
RS-485
Note
FLOW
COM
USF200S
FLOW
.,
FLOW
Current output
DC 420mA
USF200S
.,
.,
FLOW
USF200S
USF200S
Output signals
Electrical Part
USF200S
Analog output
Input signals
0300mL/min
Detecting Part
a c
b,d
2015 Vol.1