1-
4 3 different variants
Standard heatsink mounted range
ATV58 H (Heatsink)
Plate mounted range (up to 15 KW)
ATV58 P (Plate)
for installation on the machine frame (according to thermal weight)
for installation on the back of a metal cabinet with a heatsink kit
IP55 enclosed motor combination range
ATV58 E (Enclosure)
Altivar 58 Compact up to 5,5 kW
Altivar 58 Energy from 7,5 to 75 kW
1-
1-
4 Reference
ATV 58
D 28
N4
N am e
T ype
R ating
V oltage
X : w ithout filter
H : heatsink
M 2 : 208/240V
E : en closed
(and
equiped)
Z : w ithout
keypad
N 4 : 380/500V
P : plate
(w itho ut
heatsink)
X Z : w ithout
filter , w ithout
keypad
2-
Technology
Ferrite
Mini SKIIP
IGBT
Gate drivers
Capacitors
2-
Technology
2- Technology
Power rating > 15 KW
4Line Chokes integrated
4Mixt rectifier (diodes et thyristors)
Replaces the diode bridge,
the load resistor,
the contactor.
4Braking transistor
(below the bus bar)
4RFI filter
conforming with EN55011 Class A
(25 meters)
4Bus bar
2- Technology
Power rating > 15 KW
4Bus bar : strengthen all the connections inside the controller
(wiring is robust and fixed)
4Capacitors DC bus
3-
Communication
cards
(Modbus Plus, FIPIO)
(Interbus-S, Unitelway,
Profibus DP , AS-i)
Fieldbus
Modbus / RTU
integrated
Keypad
Client
application cards
(after study)
I / O extension cards
(LI,AI,AO,DT,GI)
Programming
console
PC
connection
3-2
LI3
R2
contacts of safety
relay
Assignable
R1B : contact NC
R1C : common
R1A : contact NO
mini : 10 mA, 24 V DC
maxi : 1,5 A ;250 VAC/30VDC on L
maxi : 5A ; 250 VAC/30 VDC on R
AI1
AI2
analog input
analog input
speed reference
affectable
0 -10 V
0/X mA - 20/Y mA
(by default X=4 mA,Y=20 mA)
sampling time = 4 ms
+10 V
steady at +/-1% :
10 V DC, 10 mA
not steady
24 VDC, 200 mA
R1A-R1B-R1C
+24 V
LI1,LI2.LI3,LI4
Logic inputs
usable with PLC
4-1-1
Keypad
(VW3-A58101)
4-1-1
Keypad
(VW3-A58101)
4 Terminal functions
Terminal
control
LOC
flashing before
validation
PROG
CFG
Macro-Config
Up in the menu
or increase
numerical value
ESC
ENT
FW /
RV
RUN
Display of code
fonction or menu
STOP
control keypad:
forward,reverse
stop
Nota: Stop terminal
makes red DEL speed
drive flash.
4-1-2
Programming console
4 This console can be adapted for any type of use including program
preparation and maintenance
4 Independent battery operation: Programming is also possible when
disconnected
4 The console can be connected to a PC for transferring, upploading /
downloading configurations from a PC to an ATV58
4
4
4
4
4-1-3
4-1-4
Extension cards
4 -1 -5
Option cards
4Objective :
Fixed pump command
Option card
Pressure
measurement
flow with constant
pressure
PV : Variable flow pump
P1, P2,P3 : fixed flow pump
4 -1 -5
Option cards
4Features :
downloading of 2 drive confirmation by using an ATV58 keypad
configuration switching by logic input or ATV58 keypad
After configuration switching, possibility to store it inside the control board Eprom
possibility of automatic auto-tune after a configuration switching
4 -1 -5
Option cards
4features :
switching of a maximum of 8 parameter sets
each set contains 27 predefined parameters
switching by logic input or ATV58 keypad
4-1-6
4-2
170% Tn during 60 s
200% Tn during 2 s
4 Drive overtemperature
Overload with continuous or transient current It.
Use of controller above operating temperature
Breakdown of controller fan (Thermistor on heatsink)
Automatic reduction to 2 KHz or 4 KHz if overtemperature rise at 8-1216KHz (according to controller rating)
7-
Handling
Variable torque
forward operation
General
applications
forward operation
LI1
LI2
reverse operation
reverse operation
reverse operation
LI3
2 preset speeds
jog operation
reference swtching
LI4
4 preset speeds
freewheel stop
DC injection braking
AI1
summing reference
speed
summing reference
speed
controller fault
summing reference
speed
summing reference
speed
controller fault
reference speed 1
downstream
contactor command
setpoint frequency
reached
AI2
R1
R2
forward operation
reference speed 2
controller fault
8-
4 Language
4 Macro-configuration
4 Power / Voltage Altivar 58
LnG
CFG
rEF
1st power-up
1st power-up
1st power-up
4
4
4
4
4
4
4
4
SUP
SEt
drC
CtL
I-O
FLt
FLS
APP
SL
subsequent power-ups
12345678-
Supervision
Settings
Drive
Control
I / O assignment
Faults
File
Application
or Communication
8-
4 Level 1 :
4 Level 2 :
rear view
012
8-
subsequent power-ups
LnG
Language
CtL
CFG
ESC
4-CONTROL MENU
Macro-Config
I-O
rEF
5- I/O MENU
0.37 kW 200/240V
FLt
SUP
6-Fault MENU
1-Display menu
FLS
7-FILES MENU
SEt
2-Adjust menu
APP
drC
8-APPLICATION
3-menu
SL
8-COMMUNICATION