ABOUT US EQUIPMENT
> FA U LT L O C AT I O N
We have design and manufacturing facilities both in the USA and Europe producing a
comprehensive and cost-effective range of equipment designed for the power and process TWS Travelling Wave Fault Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
industries. We are committed to producing quality products, systems and solutions for a DSFL Distribution System Fault Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
global market. Our expertise, gained from many years of experience in servicing these GPS Time Synchroniser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
international markets, allows us to introduce a high degree of systems flexibility and GLS Low Voltage Gradient Fault Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
customized solutions. FPI, P2000 Low Voltage Locators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
1 2
equipment //
FA U LT R E C O R D I N G
IDM
> data acquisition system
Each IDM DAU - equipped with a 16-bit processor, 16-bit A/D and powerful DSP processor - An upgrade package for existing Hathaway DFRII's, based on the IDM hardware, is available
processes analog input data each cycle to compute, in real time, 100 power system to provide the extra functionality of the IDM. This upgrade involves changing a number of
quantities including real and reactive power, sequence components, phasors, harmonics, cards within the DAU, whilst still retaining the original signal conditioning and isolation
frequency, etc. These quantities are then used for simultaneous fault recording, disturbance / electronics, transforming it into a new fully integrated power system monitoring device.
slow scan recording, phasor measurement, power quality recording (EN50160) and can also
be made available to other substation IEDs for integration into SCADA systems. IDM Profile
n 10 or 16 analog, 16 or 32 event acquisition unit
n Fully multitasking operating system - VxWorks
n Supports multiple concurrent applications
n Network communications - Ethernet (TCP/IP), RS232 (PPP) and Internet / Intranet
n Built in self-checking functions
3 4
equipment //
FA U LT L O C AT I O N
TWS
> travelling wave fault locator
T h e Te l e f a u l t T W S o p e r a t e s o n t h e t r a v e l l i n g w a v e p r i n c i p l e
and provides an accuracy of ±150m (±500ft). It can be used
on high voltage AC lines of any length, including those
containing sections of cable, parallel circuits, tapped loads and
series capacitors. It can also be used on HVDC lines.
The Telefault TWS provides three different modes of fault location; Type A, Type D and Type The standard version of Telefault TWS can accommodate up to eight line modules so that
E. In the Type A and D modes the fault location is determined using the transients generated eight circuits can be monitored simultaneously. An integral GPS time receiver is used to
by the fault itself. In the Type E mode faults are located using the transients generated by the provide the sub-microsecond timing accuracy required for Type D operation whilst multi-
re-closure of the circuit breaker onto the faulty line after the initial trip. The TWS is channel high-speed transient recording is used for Type A and Type D operation.
unaffected by fault resistance and provides a consistent level of accuracy many times better
than conventional ‘impedance’ type fault locators. Phase to ground faults, phase to phase TWS Profile
faults and broken conductor faults, including those clear of ground where no fault current n Travelling wave based fault location
flows, can all be located with the TWS.
n Internal modem provided as standard for remote data retrieval and configuration
n Simple and inexpensive installation
n Optional interfacing to SCADA systems / substation IEDs
5 6
equipment //
FA U LT L O C AT I O N
DSFL
> distribution system fault locator
GPS
> time synchroniser
An inexpensive overhead line fault locator for A simple, inexpensive and highly accurate
small transmission networks or distribution substation clock time synchroniser that can be
systems used with all makes of equipment
T h e Te l e f a u l t D S F L i s d e s i g n e d t o a c c u r a t e l y l o c a t e f a u l t s o n T h e Te l e f a u l t G P S p r o v i d e s t i m i n g a c c u r a t e t o ± 1 µ s u s i n g t h e
unbranched high voltage overhead line networks which may i n t e r n a t i o n a l s a t e l l i t e G l o b a l Po s i t i o n i n g S y s t e m ( G P S ) .
include short lengths of underground cable. When used on Compact and easy to install, it provides output signal formats
more complex branched networks the DSFL will accurately to match the requirements of all available Disturbance
locate faults on the main line and identify a faulty branch. Re c o r d e r s , S e q u e n c e o f E v e n t Re c o r d e r s a n d S C A D A s y s t e m s .
The Telefault DSFL uses the properties of travelling waves initiated by a fault to determine The Telefault GPS offers electrical power systems operators an inexpensive means of
the position of the fault. The preferred method of detection of the travelling waves is through significantly improving both the value of their investment in equipment and the usefulness of
the use of simple ‘clamp on’ sensors which are placed around the secondary wiring of the acquired data. Using time signals transmitted by the NAVSTAR constellation of GPS
existing protection CTs. Where no CTs are available, the signals may be derived from existing satellites, the GPS meets all the needs of all differing equipment types and manufacturers.
capacitor voltage transformers or power line signalling couplers. Local time offset from UTC can be set by the operator or at the factory.
7 8
equipment //
FA U LT L O C AT I O N
GLS
> low voltage gradient fault locator
FPI
P2000
> low voltage locators
An advanced and simple to use system for FPI - a safe and simple system for sectionalising
locating intermittent and permanent faults on intermittent faults on low voltage power cables
low voltage cables An inexpensive device for fault sectionalisation to reduce both
c u s t o m e r i n t e r r u p t i o n s a n d c u s t o m e r m i n u t e s l o s t.
T h e Te l e f a u l t G L S p r o v i d e s a m e a n s o f p r e - l o c a t i n g f a u l t s o n
low voltage cables by the voltage gradient method. These The Telefault FPI Fault Passage Indicators (bottom right) are simply placed over the links in
state of the art instruments make possible the instantaneous link boxes along the route of a suspect cable. Following any subsequent fuse operation any
measurement and recording of voltages along a faulty cable FPI units between the substation and the fault point will be triggered thereby allowing the
while fault current is flowing. faulty section to be identified. A clamp on version of the FPI is also available.
One set of GLS equipment comprises three identical voltage monitoring units configured as P2000 - a revolutionary instrument for locating
one Master and two Slaves (A and B). These identities are held in software and displayed all types of faults on low voltage power cables
when the units are switched on. They communicate by infra-red and the distance to fault is
Combines the functions of a high accuracy TDR and a
calculated and displayed by the Master unit. The GLS system has been built into small waterproof
cases which can be left connected in most link boxes and lighting columns. disturbance recorder in a compact and robust portable unit.
The Telefault P2000 (bottom left) is suitable for all types of low voltage cable faults and
especially the difficult and troublesome intermittent fault. It is connected simultaneously to
all 3 phases of the faulty LV cable for triggering/voltage recording and to allow TDR testing
on any combination of phases. Remote operation is available via the internal GSM modem.
9 10
equipment //
BREAKER MAINTENANCE
CBT
> circuit breaker test system
T h e C BT - 2 0 0 a n d C BT - 4 0 0 a r e s e l f - c o n t a i n e d p o r t a b l e t e s t s e t s
designed to perform timing and testing on high voltage circuit
breakers. Microprocessor based, the systems have the ability
to store test records in internal memory which can be
downloaded to a PC at the operators convenience.
The CBT-200 / 400 systems can monitor contact opening / closing, trip / close coil currents 16 different set-up configurations can also be stored within the CBT, any of which can be
and mechanism travel and velocity. The CBT can perform automatic result analysis using pre- accessed on site. All results can be stored within the CBT's internal memory and retrieved at
programmed limits for expected results. When a breaker test is carried out the CBT a later date via direct computer link or modem, eliminating the requirement for a PC to be
compares the actual results with those expected. Any variances outside the limits are carried on site.
indicated on the print-out and LCD display. Results are presented in both tabular and
graphical format using the built-in fixed head thermal printer. CBT Profile
n Up to two breaks per phase (CBT-200) or up to four breaks per phase (CBT-400)
n Simple to operate, can be used by less experienced personnel
n Test sequencing and cycling
n Dynamic Resistance and Tap Changer interfaces available
Te s t r e s u l t s c a n a l s o b e d o w n l o a d e d f r o m t h e C BT t o
Re p l a y P l u s w h e r e t h e y c a n b e a n a l y z e d a n d a r c h i v e d . A Re m o t e
Configuration program allows modification of test parameters
via a PC and results may also be transferred to Microsoft
Access for easy generation and customising of reports.
i n t e l l i g e n t r e s u l t s a n a l y s i s / / C BT
@
w w w. h a t h a w a y c o r p . c o m
11 12
equipment //
BREAKER MAINTENANCE
Tap Changer
Micro-Ohm
> cbt accessories
RTR
> circuit breaker response recorder
Tap Changer - a clear insight into the mechanical A diagnostic tool which can accurately assess the
condition of a tap changer transformer condition of circuit breakers with minimum of
time, effort and expense
This diagnostic tool makes use of the variable sample rates of
t h e C BT t o p e r f o r m t w o d i s t i n c t t e s t s . T h e RT R 2 0 0 a l l o w s a b r e a k e r t o b e t e s t e d w h i l e r e m a i n i n g i n
service. The system has been designed to monitor several
The interface (bottom left), performs a long duration test to quickly identify a high resistance c o m m o n s i g n a l s i n t h e c o n t r o l c i r c u i t r y o f t h e c i r c u i t b r e a k e r,
contact as the transformer is switched from first to last tap and a short duration record typically trip and close coil current, supply voltage dip, A, B or
between two taps to identify the integrity and switching sequence of the diverter resistors. C3 auxiliary contacts and trip and close initiation.
Micro-Ohm - a safe, simple facility to record the These and other electrical signals are brought to a permanently installed connector in the
‘dynamic’ contact resistance of a circuit breaker breaker mechanism cabinet. To perform a test the RTR 200 recorder is connected to this pre-
wired plug and the breaker is operated remotely. The RTR 200 stores the data from the test
This interface measures both Main and Arcing contact times, and is then disconnected to be moved to the next breaker. The resulting trace can be
considered as the fingerprint of a given circuit breaker. The essence of the RTR-200 concept
length and resistance during a ‘dynamic’ close-open operation.
is the comparison of these fingerprints.
With the Micro-Ohm Interface (bottom right), all measurements are carried out during routine
testing. This is immensely beneficial for use on circuit breakers where it may be impractical
to dismantle and visually inspect the condition of the contacts, for example SF6 switchgear.
13 14
equipment //
C O N D I T I O N M O N I TO R I N G
BCM
> breaker condition monitor
The BCM 200 is used on a one per breaker basis and monitors trip and close coil current The SSM is used to monitor up to twelve distribution breakers in a single panel or in close
profiles, auxiliary contact timing, battery voltage and charging ripple and main contact duty proximity of one another. For each breaker the SSM monitors trip and close coil current
(e.g. i²t). profiles, auxiliary contact timing, battery voltage and charging ripple, AC voltage dip and
The BCM 200E is also used on a one per breaker basis but has additional inputs to monitor duration and main contact duty (e.g. i²t).
the extra signals on transmission breakers with three independent mechanisms for each
phase. The BCM 200E monitors trip, backup trip and close coil current profiles, auxiliary BCM Profile
contact timings, battery voltage and charging ripple, main contact duty (e.g. i²t), mechanism n Available in a one per breaker or one per distribution substation configuration
travel and velocity and SF6 gas density. n Automatic ‘fingerprint’ comparison of breaker characteristics
n Design that easily fits into breaker control cabinet
n Local and remote communications
W h e n u s e d w i t h Re p l a y P l u s s o f t w a r e , a d d i t i o n a l i n f o r m a t i o n
can be obtained on protection performance, capture of fault
data, identify maintenance requirements and generate
customized reports. The BCM range is a complete solution
complementing any condition based maintenance program.
15 16
equipment //
D I S T R I B U T I O N A U TO M AT I O N
RMS
> distribution automation controller
The RMS-900 combines the latest electronic, software and manufacturing technologies to Example applications include a Distributed RTU (multiple RMS-900s networked and reporting
achieve remote control and / or automatic local control, of circuit breakers, tap changers, to another RTU, SIS or SCADA system), a Switch Controller, a Tap Changer Controller or a
reclosers, sectionalizers or capacitor switches. It combines the functions of a traditional Capacitor Bank Switch Controller. The RMS can monitor both sides of a switch and report
SCADA RTU with the added benefits of small size and low cost, transducerless status, receive and implement remote control commands, perform automatic PLC-style
measurement of AC power quantities, fault detection and harmonic analysis. control and perform auto-sectionalising and auto-reclosing as part of an automation scheme.
RMS Profile
n 9 AC analog inputs for direct connection to CTs, PTs and LPSs
n Digital signal processing - current, volts, power, frequency and phase angle measurement
n Advanced options include alarm limits, fault detection and harmonic content
n Optional Echelon FT-10 LONTALK network port
S C A D A RT U , p o w e r I E D, P L C / / R M S
@
w w w. h a t h a w a y c o r p . c o m
17 18
equipment //
S U B S TAT I O N I N T E G R AT I O N
SIS
> substation information server
The SIS is designed to gather data from IEDs and I/O modules,
process this data and make relevant useful information
available to one or multiple users, at one or more locations,
s i m u l t a n e o u s l y. C o m m u n i c a t i o n c a n b e v i a s e r i a l l i n k s ,
L A N s / WA N s , c o r p o r a t e I n t r a n e t s a n d t h e I n t e r n e t .
Each SIS can be equipped with multiple serial ports (from 3 to 32 depending on the model) The information gathered can also be presented as Web pages, allowing users to view live
with each port able to support an independent protocol. This allows communication to be substation data using standard web-browsers. Communication between SIS units is secure,
established between the SIS and almost any IED in the substation, for data retrieval and making it safe to gather information and send control commands over the Internet, or
control purposes. Information gathered by an SIS can be communicated over a TCP/IP LAN company WAN.
or WAN to other SIS units or via serial link to an existing SCADA / EMS system in its native
SCADA / EMS
protocol. SIS Profile
n Ethernet connectivity
n Up to 32 independent serial ports LA N / WA N
19 20
accessories //
S O F T WA R E
ReplayPlus
> master station
Re p l a y P l u s i s a f l e x i b l e , h i g h p e r f o r m a n c e 3 2 - b i t W i n d o w s
configuration and communications package allowing power
utilities to retrieve, analyse and manage information from a
wide range of Hathaway products throughout their
transmission and distribution networks.
The Replay™Plus Master Station suite of software applications runs on Windows 95/98, 2000 Replay™Plus Functions
and Windows NT. It provides full configuration, data retrieval, display, analysis and printing n Communications
capabilities. Predefined display screen configurations can be used to allow data to be Device configuration
n
displayed quickly in an easily interpreted format. As each record is transferred to the
n Record viewer and printing
Replay™Plus Master Station, analysis software extracts a series of key parameters that are
n Real time phasors display
stored in a database, ready for later analysis. There are also provisions to integrate third party
applications into Replay™Plus to extend its analysis capabilities. Windows .dll library files are n Harmonic analysis
available to provide developers with easy access to the raw data within the record files. n Fault location
n Automatic data analysis
n COMTRADE file import / export
To p r o v i d e t h e u s e r w i t h ‘ O p e n ’ a c c e s s t o d a t a , Re p l a y P l u s i s
built around a Microsoft Access database. The use of Access
also means that the extensive range of flexible database tools
can be used to analyse, filter and present the data acquired
f r o m s u b s t a t i o n d e v i c e s i n a u s e r c o n f i g u r a b l e m a n n e r.
a n a l y s e , c o n f i g u r e , a r c h i v e / / Re p l a y P l u s
@
w w w. h a t h a w a y c o r p . c o m
21 22
power applications
short form catalogue
locations //
15 Wildflower Way 8228 Park Meadows Drive 7661 South 180th Street 102 Lakefront Drive
Belfast Littleton Kent Hunt Valley
BT12 6TA Colorado 80124 Washington 98032-1048 Maryland 21030
Northern Ireland USA USA USA
Tel: +44 28 9022 5200 Tel: +1 303 799 8200 Tel: +1 425 251 0211 Tel: +1 410 771 0022
Fax: +44 28 9022 5225 Fax: +1 303 799 8880 Fax: +1 425 251 0113 Fax: +1 410 771 9579
@
w w w. h a t h a w a y c o r p . c o m innovation // quality+expertise