Professional Documents
Culture Documents
Power
Switches
High Power
Switches
High
Power
Switches
High Power
Switches
High Current Disconnectors
Change-over disconnectors
FA Range
3000 V ~ / = 500-8000 A 0-175 HZ
Applications
FA Range
FERRAZ FA disconnectors and change-over disconnectors range is compliant with IEC 62271-102.60694
and 60077-1 standards.
Rated insulation voltage
3 kV
The FA range includes from 1 to 6 pole devices from one of the following types :
Disconnectors (1-0)
2
1
2
1
3
2
High Power
Switches
High Power
Switches
500
1250
2000
2500
3200
4000
5000
6300
500
1250
2000
2800
4000
5000
6300
8000
High
Power
Switches
High Power
Switches
Electrical characteristics
Operation when current is off (no load operation)
140C point temperature withstand without device damage
Dielectric withstand voltage : 20 kV 50 Hz 1 mn to the ground between poles and between
terminals with all the clearance / between live parts and auxiliary contacts
Dielectric withstand voltage : 2500 V 50 Hz 1 mn between auxiliary contacts and neutral
points
Impulse voltage withstand : 20 kV 1.2 / 50 s in accordance with IEC 694
Voltage drop between terminals : ~ 30 mV
Maximum short-circuit current for one pole (50 Hz) and any device
@ Ith = 500 A
1st wave peak value
75 kA
Ir.m.s = 28 kA for 1 s
st
90 kA
Ir.m.s = 35 kA for 1 s
@ 1250 A Ith 2000A
1 wave peak value
st
@ Ith 2500 A
1 wave peak value
150 kA
Ir.m.s = 58 kA for 1 s
High
Power
Switches
High Power
Switches
High
Power
Switches
High Power
Switches
Main dimensions
Ratings </= 2000A - Operations 1-2, 1-0
Front View
Front View
Rated A
Current
(A)
500
operations
1-2, 1-0 1250
2000
operations 500
1-0-2, 1-3-2 1250
2000
32
80
80
32
80
80
15
51
51
18
53
53
76
89
89
127
130
130
G L 1p L 2P L 3p M
(mm)
5 280
5 356
26 356
5 280
5 356
26 356
285
334
334
300
395
395
127
126
126
72
93
93
153
230
230
208
263
263
97
76
76
45
45
45
82
82
82
82
82
82
142
142
163
142
142
163
229
229
271
229
229
271
316
316
379
316 75 132
316 95 180
379 95 180
2.5
3.5
7
2.5
3.5
7
Terminal Connections
32
16
High Power
Switches
High Power
Switches
High
Power
Switches
High Power
Switches
Main dimensions
Operations 1-0
Front View
Right Side View
Operations 1-3-2
Operations 1-2
2800
4000
5000
6300
8000
1
1
1
1
1
to
to
to
to
to
6
6
4
3
3
75
80
80
80
80
75
80
100
120
140
Ldimension
based on # of
1
143
163
183
203
223
Poles
2
3
228
273
313
353
393
Connecting
plates
Nb/pole J
Device weight
with 1 pole
(kg)
Additional weight
per pole
(kg)
132
194
265
337
398
82
143
194
265
337
313 398
383 493
483 633
583
683
1
2
3
4
5
10
30
50
70
90
Terminal Connections
High
Power
Switches
High Power
Switches
High
Power
Switches
High Power
Switches
Operators Dimensions
Rated Current
AC
(A)
DC
(A)
4 poles
B
0*
5 poles
B
E
0*
70+/-30
105
70+/-30
105
0*
10+/-10
60+/-20
105
10+/-10 60+/-20
105
40
2000
2000
10+/-10
60+/-20
105
40+/-40 180+/-20
145
2500
2800
10+/-10
80+/-40
160
10+/-10 80+/-40
160
220+/-80300+/-50 185
3200
4000
10+/-10
80+/-40
160
10+/-10
80+/-40
160
10+/-10
80+/-40
160
6300
70+/-30 105
180
0*
6 poles
B
E
500
5000
70+/-30 105
1250
6300
0*
3 poles
B
E
1250
5000
70+/-30 105
500
4000
0*
2 poles
B
E
105
70+/-30 105
40
180
Rated Current
AC
DC
(A)
(A)
500
1250
2000
2500
3200
4000
5000
6300
10
500
1250
2000
2800
4000
5000
6300
8000
1 pole
A
B
360
360
360
360
360
360
470
470
220
220
220
220
220
220
200
200
360
360
360
360
470
470
470
470
220
220
220
220
200
200
200
200
360
360
360
360
470
470
470
470
220
220
220
220
200
200
200
200
360
360
360
470
470
470
470
220
220
220
200
200
200
200
360
360
360
470
470
470
220
220
220
200
200
200
6 poles
A
B
360
360
360
470
470
220
220
220
200
200
145
High Power
Switches
High Power
Switches
Microswitch Contacts
Range >2000
X=80
High
Power
Switches
High Power
Switches
Main dimensions
Range >2000
X=70 up to 3 micro
switches
Ferraz Shawmut has it all for defining and offering customized solutions to meet your most specific
requirements :
. Adapted drives or control units,
. Adapted technical performances (short-circuit current capability, endurance, small load
make / break capacity).
11