Professional Documents
Culture Documents
Features
Description
The BlueOptics BO87JXX280D XENPAK transceiver is
a high performance, cost effective module supporting
a datarate up to 10Gbps with 80 Kilometer link length
on single mode fiber.
XAUI Electrical
3.125GBit/s
APD receiver
Supply voltage
Laser bias current
Laser average output power
Laser received input power
Temperature
Applications
-1-
Interface:
Commercial: 0C to +70C
Extended: -10C to +80C
Industrial: -40C to +85C
Lanes
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
Warnings
Order Information
Part No.
Temp.
BO87JXX280D
0C to +70C
BO87JXX280DEX
-10C to +80C
BO87JXX280DIN
-40C to +80C
Warranty
Every BlueOptics transceiver comes with a 5 year
replacement warranty and lifetime support.
For a warranty inquiry, please contact your CBO sales
representative.
This warranty only covers the first user of the
equipment.
Important Notice
Performance figures, data and any illustrative
material provided in this data sheet are typical and
must be specifically confirmed in writing by CBO
before they become applicable to any particular order
or contract. In accordance with the CBO policy of
continuous improvement specifications may change
without notice.
The publication of information in this data sheet does
not imply freedom from patent or other protective
rights of CBO or others.
CH
(nm)
f (THZ)
CH
(nm)
f (THZ)
17
1563.86
191.70
37
1547.72
193.70
18
1563.05
191.80
38
1546.92
193.80
19
1562.23
191.90
39
1546.12
193.90
20
1561.42
192.00
40
1545.32
194.00
21
1560.61
192.10
41
1544.53
194.10
22
1559.79
192.20
42
1543.73
194.20
23
1558.98
192.30
43
1545.32
194.30
24
1558.17
192.40
44
1542.14
194.40
25
1557.36
192.50
45
1541.35
194.50
26
1556.55
192.60
46
1540.56
194.60
27
1555.75
192.70
47
1539.77
194.70
28
1554.94
192.80
48
1538.98
194.80
29
1554.13
192.90
49
1538.19
194.90
30
1554.13
193.00
50
1537.40
195.00
31
1553.33
193.10
51
1536.61
195.10
32
1552.52
193.20
52
1535.82
195.20
33
1551.72
193.30
53
1534.04
195.30
34
1550.92
193.40
54
1534.25
195.40
35
1549.32
193.50
55
1533.47
195.50
36
1548.51
193.60
56
1532.68
195.60
61
1528.77
196.10
57
1531.90
195.70
58
1531.12
195.80
59
1530.33
195.90
60
1529.55
196.00
61
1528.77
196.10
Installation
DDM
Regulatory Compliance
-2-
Feature
Electrostatic
Standard
Co.
- IEC/EN 61000-4- 2
Discharge (ESD)
Electromagnetic
Interference (EMI)
Component
Recognition
- IEC/EN 60950, UL
RoHS
- 2002/95/EC
EMC
- EN61000-3
Class 1
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
Symbol
Ts
HA
Min.
-40
5
Typ.
Max.
85
95
Unit
C
%
Symbol
Tcase
Ambient Humidity
Transmission Distance
Coupled Fiber
HA
Min.
0
-10
-40
5
Typ.
Max.
70
80
85
70
80
Unit
C
Note
BO87JXX280D
BO87JXX280DEX
BO87JXX280DIN
%
KM
9/125m MMF
Symbol
Vcc
Icc1
Icc2
PDS
TDF
TINIT
TRESET
Min.
3.13
Typ.
3.3
Max.
3.45
1.0
1.7
4.0
500
5
Unit
V
A
A
W
ms
S
Ms
THOLD
500
ms
Symbol
Min.
Note
-100
800
Typ.
3.125
Max.
+100
1600
Unit
Gbit/s
ppm
mVPP
Symbol Min.
Typ.
Max.
POUT
0
5
ER
9
C
-25
+25
POFF
-30
Compliant with IEEE802.3ae
(class 1 laser safety)
-3-
Unit
dBm
dB
pm
dBm
Note
Note
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
1.
Symbol
IN
Min.
1270
PIN
PSAT
0.5
Typ.
Max.
1610
-24
Unit
nm
dBM
dBm
Note
1
Notes:
-12
31
ER=9dB; BER =<10 @PRBS=2 -1 non-return-to-zero.
Symbol
GND
GND
GND
Reserved
3.3 V
3.3 V
APS
APS
LASI
I/O
I
I
I
I
I
I
I
O
Logic
10
11
RESET
VEND SPECIFIC
I
-
1.2V CMOS
-
12
13
14
TX ON/OFF
Reserved
MOD DETECT
I
O
1.2V CMOS
-
15
VEND SPECIFIC
16
VEND SPECIFIC
17
18
19
20
21
22
23
24
MDIO
MDC
PRTAD4
PRTAD3
PRTAD2
PRTAD1
PRTAD0
VEND SPECIFIC
I/O
I
I
I
I
I
I
-
Open Drain
1.2V CMOS
1.2V CMOS
1.2V CMOS
1.2V CMOS
1.2V CMOS
1.2V CMOS
-
25
26
APS SET
RESERVED
O
-
27
28
29
30
APS SENSE
APS
APS
3.3 V
O
I
I
I
Analog
Supply
Supply
Supply
Supply
Supply
Supply
Supply
Supply
Supply
Supply
Open Drain
-4-
Description
Electrical ground
Electrical ground
Electrical ground
Reserved
Power
Power
Adaptive Power Supply
Adaptive Power Supply
Link Alarm Status Interrupt. 10-22k
ohm pull up on host.
TX OFF when MDIO RESET
Vendor Specific Pin. Leave
unconnected.
Transmitter ON/OFF
Reserved
Pulled low inside module through
1k ohm.
Vendor Specific Pin. Leave
unconnected.
Vendor Specific Pin. Leave
unconnected.
Management Data IO
Management Data Clock
Port Address bit 4 (Low=0)
Port Address bit 3 (Low=0)
Port Address bit 2 (Low=0)
Port Address bit 1 (Low=0)
Port Address bit 0 (Low=0)
Vendor Specific Pin. Leave
unconnected.
Feedback output for APS
Reserved for Avalanche Photodiode
use
APS Sense Connection
Adaptive Power Supply
Adaptive Power Supply
Power
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
3.3 V
Reserved
GND
GND
GND
GND
GND
Reserved
Reserved
GND
RX LANE 0+
RX LANE 0GND
RX LANE 1+
RX LANE 1GND
RX LANE 2+
RX LANE 2GND
RX LANE 3+
RX LANE 3GND
GND
GND
TX LANE 0+
TX LANE 0GND
TX LANE 1+
TX LANE 1GND
TX LANE 2+
TX LANE 2GND
TX LANE 3+
TX LANE 3GND
Reserved
Reserved
GND
GND
I
I
I
I
I
I
I
O
O
I
O
O
I
O
O
I
O
O
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Supply
Supply
Supply
Supply
Supply
Supply
Supply
AC
AC
Supply
AC
AC
Supply
AC
AC
Supply
AC
AC
Supply
Supply
Supply
AC
AC
Supply
AC
AC
Supply
AC
AC
Supply
AC
AC
Supply
AC
AC
Supply
Supply
-5-
Power
Reserved
Electrical Ground
Electrical Ground
Electrical Ground
Electrical Ground
Electrical Ground
Reserved
Reserved
Electrical Ground
Module XAUI Output Lane 0+
Module XAUI Output Lane 0Electrical Ground
Module XAUI Output Lane 1+
Module XAUI Output Lane 1Electrical Ground
Module XAUI Output Lane 2+
Module XAUI Output Lane 2Electrical Ground
Module XAUI Output Lane 3+
Module XAUI Output Lane 3Electrical Ground
Electrical Ground
Electrical Ground
Module XAUI Input Lane 0+
Module XAUI Input Lane 0Electrical Ground
Module XAUI Input Lane 1+
Module XAUI Input Lane 1Electrical Ground
Module XAUI Input Lane 2+
Module XAUI Input Lane 2Electrical Ground
Module XAUI Input Lane 3+
Module XAUI Input Lane 3Electrical Ground
Reserved
Reserved
Electrical Ground
Electrical Ground
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
8. EEPROM Information
Device
Address
(Dec)
Register
Address
(Hex)
PMA/PMD 1
0x0000
0x0001
0x0002
PMA/PMD Control1
PMA/PMD Status1
PMA/PMD Device Identifier0
0x0003
PCS 3
PHY XS 4
PCS Control1
PCS Status1
PCS Device
Identifier0
PCS Device
-6-
PHY XS Control1
PHY XS Status1
PHY XS Device
Identifier0
PHY XS Device
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
0x0004
0x0005
0x0006
0x0007
0x0008
0x0009
0x000A
0x000E
0x000F
0x0018
Reserved
0x0019
Reserved
0x0020
0x0021
0x0022
Reserved
Reserved
Reserved
0x0023
Reserved
0x0024
Reserved
0x0025
0x0026
0x0027
0x0028
0x0029
0x002A
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
0x002B
Reserved
0x8000
0x8007 0x807D
0x807E0x80AD
Identifier1
PCS Speed Ability
Identifier1
PHY XS Speed
Ability
PHY XS Device in
Package1
PHY XS Device in
Package2
Reserved
PHY XS Status2
Reserved
Reserved
Reserved
Reserved
10G PHY XGXS Lane
Status
10G PHY XGXS Test
Control
Reserved
PCS Device in
Package1
PCS Device in
Package2
PCS Control2
PCS Status2
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
10GBASE-R PCS
Status1
10GBASE-R PCS
Status2
10GBASE-R PCS
Test pattern Seed A0
10GBASE-R PCS
Test pattern Seed A1
10GBASE-R PCS
Test pattern Seed A2
10GBASE-R PCS
Test pattern Seed A3
10GBASE-R PCS
Test pattern Seed B0
10GBASE-R PCS
Test pattern Seed B1
10GBASE-R PCS
Test pattern Seed B2
10GBASE-R PCS
Test pattern Seed B3
10GBASE-R PCS
Test pattern Control
10GBASE-R PCS
Test pattern Error
counter
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Customer AREA
-7-
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
0x80AE 0x8106
0x9000
0x9001
0x9002
0x9003
0x9004
0x9005
0x9006
0x9007
0xA000 0xA027
0xA060 0xA069
0xA06F
0xA070
0xA071
0xA074
0xA075
0xA100
Reserved
Vendor Specific
RX_ALARM Control (XENPAK
Register)
TX_ALARM Control (XENPAK
Register)
LASI Control (XENPAK Register)
RX_ALARM Status (XENPAK
Register)
TX_ALARM Status (XENPAK
Register)
LASI Status (XENPAK Register)
TX_FLAG Control Bits
RX_FLAG Control Bits
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
-8-
BO77JXX280D
X2 DWDM 10G C-Band 80KM
RoHS Compliant Optical Transceiver
Contact Information
CBO GmbH
Friedhofstrae 25
45478 Mlheim an der Ruhr
Germany
Tel.:
Fax.:
eMail:
web:
-9-