You are on page 1of 4

1.

-Resistencia ampermetro-voltmetro
a) campo

E1-E2
1
180.1
90.5
1.99005525

V
I
R(k)

2
169.7
84.2
2.01543943

3
149.6
73.7
2.02985075

b) armadura

A1-A2
1

13.8

16.6

12.3

11.9

9.1

I
0.7
R( 19.7142857
)
1

0.88
18.8636363
6

0.63
19.5238095
2

0.57
20.8771929
8

0.44

20.68181818

c) campo serie
D1-D2
V
I
R()

9.9

12.8

14.9

16.6

19.7

0.41
0.54
0.63
24.14634
15 23.7037037 23.6507937

0.7

0.84

23.7142857

23.452381

Resistencias finales de campo y armadura

E1-E2
R

2.01 k

A1-A2
20.2

D1-D2
23.5

2) medicin inductancia
a) inductancia campo serie

V
I
Z
XL
L(H)

1
116.1
0.4
290.25
289.297101
0.76736631

D1-D2
2
142
0.53
267.924528
266.891931
0.70793616

3
163.8
0.63
260
258.9358029
0.686832368

b) armadura

V
I
Z
XL
L(H)

1
67.5
0.43
156.9767442
155.6716359
0.412922111

A1-A2
2
3
81.8
96
0.52
0.61
157.3076923
157.3770492
156.0053527
156.0752883
0.413807301
0.413992807

4
110.5
0.71
155.633803
154.317337
0.40932981

c) campo

V
I
Z
XL(k)
L(H)

3) curva Ea If

1
131.6
3
43.8666667
43.8205927
116.23499

E1-E2
2
3
143
152.9
3.48
3.76
41.091954
40.6648936
41.0427653
40.6151877
108.86675
107.73259

4
160.7
3.95
40.6835443
40.6338612
107.78213

La curva (Ea-Ia) representa la curva de saturacin

EA-IF
180
160
140
120
100
80
60
40
20
0

10

20

30

40

50

60

70

4) medida inductancia rotacional

VA
Ifm
W(RPM)
GAF

86

0
0
1800

27.83
40.6
9.8
20.3
1800
18000
15.06523 10.61007
03
96

17
5
18000
18.03713
528

30.6
15.1
18000
10.75061
043

72.4
25.5
18000
15.06215
218

100.4
114.8
125
135.7
144.8
154
30.3
35.6
41.4
45.5
50.7
55.3
60.5
18000
18000
18000
18000
18000
18000
18000
15.057208 14.961404 14.71059 14.57428 14.19909 13.89095 13.50373
64
35
34
51
07
41
76

Se observ que el generador no generaba tensin en vacio.esto se


debe a la remanencia suprimida.