You are on page 1of 28
MS 1525:2007 MALAYSIAN STANDARD CODE OF PRACTICE ON ENERGY EFFICIENCY AND USE OF RENEWABLE ENERGY FOR NON-RESIDENTIAL BUILDINGS (FIRST REVISION) Ics: 91.040.01 Descriptors: energy effcancy renewable energy. nonresidential buldngs, code of practice, energy conservaton| © Copyright 2007 DEPARTMENT OF STANDARDS MALAYSIA SIRIM TRU Tn LL 214335 CONTENTS Page Commitee represent. Soot eee ii Forewor a ee v © Introduction... 1 1 Scope. 2 2 Referenced documents, 2 3 Definitions... 2 4 Architectural and passive design stteay 4 5 Building envelope. 10 6 Lighting... — 20 7 Electric power and distribution. - : 24 3 Ae-conatoning and mechantal veniaton (ACH) syst, 28 9 Energy management control system, : foe 40 10 Building Energy Simulation Method. oo 44 Tables 1 Daylight factors and distribution, rere 6 2 Impact of air velocity on occupants. svnannenn : 3 3 Window design requirements... 10 4 Solar correction factors... co 12 5 Shading coefficient of horizontal projections. — 13 6 Shading coefficient of vertical projections....--.no.-.cee ee 13 7 Shading coefficient of egg-crate louvres... 14 8 —_Trade-off for daylighting controls... 7 15 9 Maximum U-value for roof (Wim"k), soos 15 10 Equivalent temperature difference for roof cnn S Ww 11 Solar correction factor for roof... co 17 12 Maximum percent skylight area... . 7 8 13 Recommended average illuminance levels. 24 14 Unitlighting power (including ballast loss) allowance... 22 15 Class definition for 4-pole Motors... neon 25 16 Class definition for 2-pole motors... onnnnanannnn =o 26 17 Location of distribution transformers... os ar 18 ACMV system equipment, electrically driven: Standard rating 38 temperatures - cooling, 19 Unitary ar conditioners, electrically driven: Minimum COP — cooling... 35 20 ACMV system components, electrically driven for water chillers: ‘Standard rating conditions — cooling. 36 21 Water chilling packages, electrically driven: Minimum COP (and kWelRT) or IPLV... 37 22 ACMVsystem cooling equipmenticompor rating conditions ~ cooling... 38 23 ACMV system cooling euipmenicomponents, hea operaod: Minimum COP cooling... 30 Figure 1 Sunpath diagram....... : 7 Appendix A Bibliography. : . = 468 (© STANDARDS MALAYSIA 2007 - All ghis reserved MS 1525:2007 ‘Committee representation (continued) ‘The Working Group on Electie Power and Distribution which consists of representatives from the folowing organisations: ‘Associaton of Consuting Engincers Malaysia Danish intematonl Development Asstance

You might also like