You are on page 1of 1

75

500
3500

03
50 x Bar Dia.

500
03

3500

500
500

04

T8-03
01

T8-03

01

SECTION X01-X01
4T25-01+2T20-02

06

06

06

06

06

06

T8-03

04

04

05

05

REV

T8-03
04

01

02

02

C1

CLIENT

GF LVL

T8-03

01

250
SECTION X01-X01
4T25-01+2T20-02

C2

C0

T8-03
01

SIGN DATE APPROVED

C3

SECTION X02-X02

50 x Bar Dia.

01

REVISION

C4

04

250

500

02

T8-03

4T20-04+2T16-05

500

02

07

01

01

02

02

01

01

T8-03

250

PROJECT

SECTION X01-X01

PROPOSED HOTEL
IN
MOGADISHU

4T20-01+2T16-02

500

SECTION X01-X01
4T20-01+2T16-02

01

250

500

250

T8-03

03

T8-03

01

03

01

05

GF LVL

500

T8-03

05

SECTION X02-X02

03

02

01

Depth to be
Det. on site

02

GF LVL

07

LEVEL 1

4T25-04+2T20-05

500

01

04

250

50 x Bar Dia.

50 x Bar Dia.

01

Depth to be
Det. on site

500

GF LVL

04

04

4T25-04+2T20-05

08

SECTION X03-X03

50 x Bar Dia.

04

SECTION X02-X02

08

250

Depth to be
Det. on site

03

LEVEL 1

T8-03

07

LEVEL 2

03

05

07

SECTION X04-X04

06

4000

05

250

4T20-04+2T16-05

500

04

04

SECTION X02-X02

03

50 x Bar Dia.

04

04

T8-03

6T16-06

500

T8-03

4000

03

LEVEL 1

09

4T16-07+2T12-08

T8-03

SECTION X03-X03

09

250

4T20-06+2T16-07

03

05

07

250

4000

05

250

4000

SECTION X03-X03

500

04

04

50 x Bar Dia.

500

250

50 x Bar Dia.

50 x Bar Dia.

500

04

07
06

4T20-06+2T16-07

LEVEL 1

06

75

SECTION X03-X03

06

06

09

LEVEL 3

08

LEVEL 2

09

6T12-09

T8-03

SECTION X04-X04

T8-03

75

03

250

Depth to be
Det. on site

07

06

6T16-06

75

07

08

09

SECTION X05-X05

03

06

06

08

09

250

6T16-08

50 x Bar Dia.

3500

T8-03

03

3500

LEVEL 2
06

08

250

500

06

06

T8-03

SECTION X04-X04

500

06

3500

500

LEVEL 2

08

08

6T16-08

50 x Bar Dia.

50 x Bar Dia.

03

3500

SECTION X04-X04

08

250

4T16-07+2T12-08

06

T8-03
08

250

06

08

09

50 x Bar Dia.

07

03

07

08

T8-03

4T16-09+2T12-10

500

T8-03

10

LEVEL 3

03

500

08

10

SECTION X05-X05
50 x Bar Dia.

50 x Bar Dia.

03
50 x Bar Dia.

500

08

LEVEL 3
08

09

250

4T16-09+2T12-10

08

09

09

SECTION X05-X05

6T12-09

LEVEL 3

09

250

3500

3500

SECTION X05-X05

07

T8-03
09

250

07

10

ROOF LVL

3500

09

03

09

10

03

T8-03

03

09

09

3500

09

09

3500

09

3500

09

ROOF LVL

500

ROOF LVL

500

ROOF LVL

NOTES:
1. All dimensions are in millimeters
2. Use class class 25 for bases &beams ,
class 25 for columns and 20 for the slab
3.Read this drawing in conjunction
with relevant Architectural drawings.
4. Minimum cover for concrete is:
a. Foundation = 50mm
b. Columns = 25mm
c. Beams = 25mm
d. Slabs = 25mm
5. All reinforcement to be twisted bars
B.S 4449.
6. All steel reinforcement must be
approved by the Structural Engineer

CONSULTING CIVIL STRUCTURAL ENGINEER

BELHMANN CONSULTANTS

COLUMN C05
TYPE 5

COLUMN C06
TYPE 6

COLUMN C07
TYPE 7

P.O BOX 36014-00200,


NAIROBI, KENYA
TEL:254717865382/704845027

COLUMN C08
TYPE 8

belhmannconsultants@gmail.com
ARCHITECT

DRAWING TITLE

COLUMN DETAILS

Designed by
Checked by

Drawn by

D.O.O
N.B

Scale

Date

AS INDICATED ON THE DRAWING

Job No.
Status

01-MOG

B.O.O
D.O.O
March 2016

Approved by

ACAD File:

Drawing No.01/2016/MOG-12

STR01-MOG
CO REV

You might also like