You are on page 1of 2

Ejemplo de clculo del rea

Q = 328306 W
Tlm = 40.8929C
Process fluid hi = 1000 W/m2K
Vaporizing ho = 6000 W/m2K
Assume all heat transfer in vaporizing zone
U 1/hi + 1/ho = 857.14 W/m2K
A = 9.36m2

m {C p T }
Q=

m
=

{(4.184 kJ/kgC)(70C) + 2081.3}

H-1
A = 9.36 m2
stainless steel, Kettle, process stream in shell
Q = 328.306KW
D.H-2
A = 0.2815 m2
C. total, , stainless steel process stream in tubes
Q = 32.8442KW
CMP-1
Axial compressor or blower, stainless steel,
Q = 752.341KW
design capacity = 4000 kW
70% efficient

C-1
A = 5.015 m2
stainless steel, C. total process stream in tubes
Q = 568.7KW
F.R1
A = 23.48 m2
stainless steel, Kettle, process stream in shell
Q = 2738.905KW
B-1
stainless steel, centrigugal
power = 3.7W (actual)
80% efficient