Thebasicdesigndatafortheeffectiveuseofthedemisterareasperthebelow.
(Thesedataaretheresultofatest.)

1.OperatignVelocity
(1)Allowablemax.gasVelocity

News&Notice

(2)OperationVelocity
Vact=0.2(min)~1.0(max)xVmax.=0.8(min)xVmax.
k=Coefficient=0.108(HD193Style)
Ingeneral,operatingvelocityiscalculatedbasedontheaboveequation,butreentrainmenthappensatoverVmax.speedsoitissafetouseatlower
thanthat.Thevalueofkisdifferent,dependingontheconditionsforuse,buttheviscosityofaliquidandtheloadofmistquantityarenotoftenclear
soitisusedbasedonthetestresult.Table1showstherangeofVactbygasdensity(eg).
2.SeparationEfficiency
Thetheoreticalvalueofefficiencycanbecalculatedasperthebelow,butitisconvenientifthetestresultofTable4isused.

3.PressureDrop
Ifthedemisterisused,thepressuredropwillbe0.1"~1.0"WG.Theoretically,itcanbecalculatedbasedonthebelowequation.

http://www.dsdemister.com/eng/library.htm