You are on page 1of 65

CMO LAT NI SE CoDe

SISTEMA DE ANTENAS

NOKIA NODE-B SITE

Antenna
Systems
Power Systems

Cellular
Transmission
Systems
For internal use
2
Nokia Siemens Networks

Shelters,
Towers,
Masts,
Poles

Site

Base
Stations

Presentation / Author / Date

Installation
Materials

ANTENNA LINE

For internal use


3
Nokia Siemens Networks

Presentation / Author / Date

PRODUCTOS DE SISTEMA DE ANTENAS


Antenna

Jumper cable
Mast Head
Amplifier
and BiasT

Connector

Feeder
clamps
Grounding kit
Combiners
diplexers

Feeder
cable

For internal use


NokiaAuxiliary
Product
Management v.
1.0 04.2002
Nokia Siemens
Networks
Presentation
/ Author / Date

4 4

EMP protector

ANTENNA LINE
Instalacin de Antenas
TM 3G Antenna:

CS72761.08 (K742212) XPol F 1710-2170M 65deg 18dBi 0-8T


CS72761.11 (K742215) XPol F 1710-2170M 65deg 18dBi 0-10T
CS72191.14 DT-kit for A, F & Euro panel
CS72196 Clamp 50-115mm for A, F & Euro panel

For internal use


5
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Downtilt Electrico Ajustable

Combina las ventajes de poder


ajustar el downtilt sin afectar el
patron de radiacin de la antena.

Downtilt es ajustado
usando un rotary knob
en la parte inferiro de
la antena.

For internal use


6
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
MHA (Mast Head Amplifier)

Incrementa la cobertura
Balancea enlace Rx-Tx
Mejora la sensibilidad del sistema
Disminuye la potencia de transmisin del equipo movil.
BTS RX sin MHA
BTS RX con MHA

For internal use


7
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Nokia Mast Head Amplifier

Antenna

2 MHAs
mounted backto-back

Jumper

Mast Head
Amplifier

Bias T
Drenaje

For internal use


8
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Beneficios del MHA

Totalmente integrado y probado de


acuerdo a los requerimeintos de los
sistemas.
Compacto y facil de instalar
Compensa la perdida por cable y
combinadores en el uplink
Disminuye la potencia de
transmisin del equipo movil.
Reduce la interferencia inter-cell e
intra-cell
For internal use
9
Nokia Siemens Networks

Presentation / Author / Date

2 MHAs
instalados backto-back

Diagrama de Bloques del Mast Head Amplifier


BTS

ANTENNA

TX FILTER

Internal
BIAS
TEE

BYPASS PATH

RXin FILTER

RXout FILTER

DC CURRENT

Current Sense, Bypass & Alarm Control Circuit


For internal use
10
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Bias-T

Energiza el MHA atravez de la linea de transmisin.


Maneja las alarmas del MHA y del Bias-t

BTS port

Fwd. power
coupler

Alarm out
DC pwr in

For internal use


11
Nokia Siemens Networks

DC block
(capacitor)

Rvrs. power
coupler

Broadband detectors
level comparators
alarm-sense logic

RF choke
(inductor)

Presentation / Author / Date

Lightning
protection

ANT port

Lightning protection (MHA + BiasT)


BiasT)

ANT.
Jumper

MHA

Ant. port

Transorber (fast)

/4
Large area quarter
wave stub (>25mm2)
(for imped.matching)

LNA
LNA

Gas-tube (spark gap)


(high energy)

BTS port
Jumper
Feeder

PTFE tube

BiasT
BTS

RF band pass filter


DC-Input
with
large conducting
areas
For internal use
12
Nokia Siemens
Presentation / Author / Date
andNetworks
high DC isolation

/4

ANTENNA LINE
Instalacin del MHA

For internal use


13
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del MHA Installation con bracket especial

Braket montado en mastil


(40-110 mm diameter)

For internal use


14
Nokia Siemens Networks

Presentation / Author / Date

3 MHAs instalados en el mastil

ANTENNA LINE
Colocando el downtilt y orientando las antenas
Esta
ok??

Tomando un punto
de referencia

For internal use


15
Nokia Siemens Networks

Presentation / Author / Date

Direccionando la antena
Iaquierda...Dere
cha...-10 grados

ANTENNA LINE
Colocando el downtilt y orientando las antenas
OK
pongamos
lo a -6
grados

Vertical

REQUIREMENT +/- 0,5


Antenna Tilting Angle
(Mechanical)

For internal use


16
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Mejora del funcionamiento de la Red

Eveluacin de las inclinaciones de las antenas

Triple band
824-960 MHz
1710-1880
MHz 1920Dual band 2170 MHz
824-96 &
17102170MHz
Broadband
17102170MHz
Single band
Tilt
1920electrico
2170MHz
Polarizacin
ajustable
Cruzada
Polarizacin

Tilt
Electrico

Vertical
Tilt
Mecanico

Eficiencia
For internal use
17
Nokia Siemens Networks

Presentation / Author / Date

Nokia
RealTil
t

ANTENNA LINE
Downtilt Mecanico

Antena inclinada fisicamente


de tal manera que el lobulo
principal se deforma en el
piso.
La reduccin de la seal en
la direccin principal pero
no cambia el angulo de
apertura de la antena.
El planeaminto de la
red
Se dificulta al
alterarse el patron de
radiacin.
For internal use
18
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Downtilt Electico

Antena permanece vertical

La fase de la seal que van a


los dipolos varia causando el
tilt electrico.
El patron de radiacin no se
altera
Se agura un exacto
planeamiento de red
For internal use
19
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin Antenna
Ajustando el downtilt mecanico (Kathrein)

Usar la escala en el
kit de downtilt para
medir la inclinacin.
Confirmar con un
medidor de angulo
Si la escala no existe
usar un medidor de
agulo

For internal use


20
Nokia Siemens Networks

Presentation / Author / Date

Ajustando el downtilt electrico (Kathrein)

ANTENNA LINE
Antenna Line System
Item

Descripcin

Las antenas pueden ser de polarizacin vertical, cruzada y


direccionales u omni-direccionales
Los jumpers son cables flex de , y son usados en los extremos
de los coaxiales. Estos protegen los conectores ante posibles
movimientos bruscos de los coaxiales.
Los conectores 7/16 tienen la clasificacin IP68.

El kit de tierra asegura que la linea de transmisin tenga


proteccin de DC ante posibles descargas.

2
3

El cable coaxial de RF puede ser de diferentes medidas, ejem.


1/2, 7/8 , 1 5/8, etc, dependiendo de la altura de la torre
clamps son de acero y plastico. Son facil de instalar. El diseo de
los clamps evita que se puedan ajustar demasiado y daar el
cable.

4
5
6
7

Un compacto EMP protg la BTS ante posibles descargas.


(opcional)

Antenna Line System without MHA


For internal use
21
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE

Note:The photo shows the Antenna system at


outdoor site in Singapore.

For internal use


22
Nokia Siemens Networks

Presentation / Author / Date

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

SOLUCION DE INSTALACION DE ANTENA

1 SECTOR (X+0+0
(X+0+0)
X+0+0)
X= cantidad de TRX
For internal use
23
Nokia Siemens Networks

Presentation / Author / Date

2 SECTOR (X+X+0
(X+X+0)
X+X+0)
X= cantidad de TRX

3 SECTOR (X+X+X
X+X+X)
(X+X+X)
X= cantidad de TRX

ANTENNA LINE
Sencillo

OUTDOO
R

INDOOR

Revisar el rango de frecuencia del material utilizado


Se deben usar conectores aprobados
Los conectores deben ser los adecuados de acuerdo al tipo
de cable (fabricante)
Los cables deben estar etiquetados a ambos extremos
Se deben emplear adecuadas herramientas para ensamblar
los conectores.
Todos los cables deben estar ajustados adecuadamente.
For internal use
24
Nokia Siemens Networks

Presentation / Author / Date

EMP

ANTENNA LINE
Con MHA

OUTDOO
R

INDOOR

Bias-T

Revisar el rango de frecuencia del material utilizado


Se deben usar conectores aprobados
Los conectores deben ser los adecuados de acuerdo al tipo
de cable (fabricante)
Los cables deben estar etiquetados a ambos extremos
Se deben emplear adecuadas herramientas para ensamblar
los conectores.
Todos los cables deben estar ajustados adecuadamente.
For internal use
25
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Calculo de la atenuacin del coaxial
Atenuacin en Jumper cable
0.68dB
(2 jumpers con 4 conectores)
Atenuacin en conector de antena ( 2 conectores )
0.10 dB
Atenuacin en EMP
dB
Atenaucin en coaxial

0.10
RF 7/8
5.53 dB 100m
RF 1 5/8
3.36 dB 100m

Ejemplo:
Se tiene un recorido de 36 m. La atenuacin limite es
Que cable se deb usar?
0.1 + 0.1 + 0.68 + 36m X 0.0553 = 3 dB
-> 7/8" feeder cable

For internal use


26
Nokia Siemens Networks

Presentation / Author / Date

3 dB.

ANTENNA LINE
Atenuacin en Coaxiales

CABLE

FREQUENCIA
900 MHz

FREQUENCIA
1800 MHz

FREQUENCIA
2000 MHz

RFF 3/8-50

13.9 dB/100m

20.5 dB/100m

21.8 dB/100m

RFF 1/2-50

10.6 dB/100m

15.6 dB/100m

16.7 dB/100m

RF 1/2-50

6.88 dB/100m

10.1 dB/100m

10.7 dB/100m

RF 7/8
7/8-50
!!

3.53 dB/100m

5.04 dB/100m

5.53 dB/100m AVA

RF 1 1/4-50

2.74 dB/100m

4.12 dB/100m

4.39 dB/100m

RF 1 5/8
5/8-50
!!

2.11 dB/100m

3.05 dB/100m

3.36 dB/100m AVA

NOTE: Given values are for NK Cables feeder cables except 7/8 and 15/8 are for Andrew
AVA cable type, other manufacturers may have different values, check the proper values
before implementation from manufacturers data sheets
For internal use
27
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Intrucciones de instalacin de antenas.

1.

Verificar que el soporte de antena este colocado en la posicin correcta.

2.

Izar la antena hasta el soporte


Nota: Prevenir los problemas que se puedan encontrar debido a condiciones
climaticas para evitar que la antena sufra daos.

3.

Instalar la antena totalmente vertical o con la inclinacin indicada por planning.

4.

Usar las especificaiones de la antena para tener en cuanta la separacin vertical y


horizontal con otras antenas.

5.

Conectar el Jumper en la antena, el otro extremo quedara desconectado


momentaneamente
Nota: proteger el conector libre con cinta.

6.

Colocar clamps en el jumper hacia la antena

For internal use


28
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Curvatura de cables

La curvatura de los cables deben seguir las escificaciones deNSN para


evitar daos y aumentar la perdida en el cable.
No permitido:
MAL

MAL

For internal use


29
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Curvatura de cables

CABLE

CURVATURA MINIMA
PARA UNA SOLA CURVA

CURVATURA MINIMA
PARA VARIAS CURVAS

RFF 3/8-50

13 mm

25 mm

RFF 1/2-50

15 mm

30 mm

RF 1/2-50

80 mm

160 mm

RF 7/8-50

120 mm

250 mm

RF 1 1/4-50

200 mm

350 mm

RF 1 5/8-50

250 mm

500 mm

NOTE: Given values are for NK Cables feeder cables, other manufacturers may have
different values, check the proper values before implementation from manufacturers
data sheets
For internal use
30
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Curvatura de cables

FEEDER
TYPE
REPEATED

REPEATED
BENDING RADIUS

SINGLE BENDING
RADIUS

RF 1 5/8

500mm

250mm

RF 1 1/4

350mm

200mm

RF 7/8

250mm

120mm

RF 1/2

160mm

80mm

RFF 1/2

30m
m
25m
m

RFF 3/8

For internal use


31
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Distancia entre clamps

Seguir las especificaciones de los cables.


Cable

Distancia entre clamps


Optima

Maxima

1/4 Superflex

150mm

200mm

3/8 Superflex

150mm

200mm

1/2 Superflex

250mm

300mm

1 /2 Feeder

500mm

600mm

7/8 Feeder

900mm

1000mm

1-5/8 Feeder

1000mm

1400mm

NOTE: Given values are for NK Cables feeder cables, other manufacturers
manufacturers
cturers may have
different values, check the proper values before implementation from manufacturer
manufacturers
data sheets
For internal use
32
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Distancia entre clamps

Seguir las especificaciones de los cables.


RF 1/4 superflex

150mm

200mm (Max)

RF 3/8 superflex

150mm

200mm (Max)

RFF 1/2
superflex

250mm

300mm (Max)

RF 1/2

RF 7/8

RF 1 5/8

For internal use


33
Nokia Siemens Networks

500mm

600mm (Max)

900mm

1000mm

Presentation / Author / Date

1000mm (Max)

1400mm (Max)

ANTENNA LINE
Instalacin de coaxial y jumper

For internal use


34
Nokia Siemens Networks

Presentation / Author / Date

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

ANTENNA LINE
Instalacin de cables coaxiales

Tener cuidado con:


Minimo radio de curvatura
Maxima fuerza al jalar los cables
Manejo del carrete de en el que viene el cable
Correcto manejo de las herramientas

For internal use


35
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Herramientas y conectorizacin

Usar guantes!
Revisar el estado de las herramientas
Revisar los conectores y su protecci
proteccin contra el agua
Revisar las instrucciones de instalaci
instalacin: medicin correcta
para cortar, etc.
Usar las herramientas con cuidado, no ajustar demasiado
antes de cortar.
cortar.
Usar el torque correcto en todas las conexiones.

For internal use


36
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de cables coaxiales

CRITICO: Tener cuidado al izar los cables, se podria daar la


proteccin del cable
EVITAR: Izar el cable con fuerzas desiguales.
USAR: Izamiento con cuidado.
TENER CUIDADO CON: Superficies que puedan daar el
cables, curvaturas excesivas, etc

For internal use


37
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Tipo de cable por ditancia

0 m < L < 8 m -RF 1/2"


9 m < L < 35 m

-RF 7/8"

36 m < L < 50 m
L > 50m adicionar MHA
5/8"

-RF 1-5/8"

Este ejemplo puede variar dependiendo del proyecto.!

For internal use


38
Nokia Siemens Networks

Presentation / Author / Date

RF 1-

ANTENNA LINE
Instalacin de clamps

Tener cuidado con superficies con filo !


Clamps AJUSTADOS AL MAXIMO pueden afectar el
cable y originar perdidas en el.
Tengan cuidado en NO PERDER los anillos de
plastico
Los cables debern tener como terminacin una
impedancia de carga (o fuente) resistiva igual a
una impedancia caracteristica, generalmente 50
.

For internal use


39
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del jumper

Incorrecta
curvatura

Correcta curvatura

El jumper es fijado
Con clamps

Cables sueltos,
sueltos, sin fijaci
fijacin

OK
For internal use
40
Nokia Siemens Networks

Presentation / Author / Date

NOK :

ANTENNA LINE
Instalacin de jumper
La distancia de clamps en un jumper es de 500mm
Para un jumper de 1.5m , se deben colocar minimo 2 clamps y para un
jumper de 3m , se deben colocar minimo 4 clamps.
clamps

Jumper de 1.5m
2 clamps ( minimo)
minimo)

For internal use


41
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de jumper

Los jumpers se deben instalar los mas


rectos posible
Evitar curvas adicionales.
Se deben usar las herramientas
adecuadas.
Los cables deben ser fijados
apropiadamente.
De preferencia se deben usar cables
prefabricados.

For internal use


42
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin de jumpers

Usar las herramientas correctas


La conexin de los jumpers deben tener
el torque correcto
Conector 7/16 ---- 25Nm

For internal use


43
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Prueba de laboratorio en cables flojos

Efectos de cables flojos:


flojos:
Tambien los conectores 7/16 son sensibles a los torques correctos. Cuando se
afloja un conector, al principio se tendran problemas de intermodulacin, luego
se perderan valores de retorno. Facilmete se pueden tener perdidas de 6...12dB
en los valores de retorno, cuando un conector es ajustado muy suave
( 5...10Nm). Casi toda la potencia pasara atravez del cable, pero se tendran
alarmas de VSWR y la perdida por insersin puede llegar a aumentar en 1..2dB.

For internal use


44
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de jumpers

NOK

OK

OK
Jumpe
r

For internal use


45
Nokia Siemens Networks

Jumpe
r

Presentation / Author / Date

NOK

ANTENNA LINE
Instalacin de jumpers

OK

NOK

O
K

OK
Jumper

For internal use


46
Nokia Siemens Networks

Jumper

Presentation / Author / Date

NOK

ANTENNA LINE
Vulcanizado de conectores

Almecenar cables bajo techo


Revisar los extremos de los cables
Proteger el extremo del cable despues de cortarlo; de preferencia
con cinta vulcanizante
Kits de tierra: Sellado IP 67. Terminal del cable de tierra de ser
revisado. Revisar que este bien ajustado.

For internal use


47
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del jumper en BTS

For internal use


48
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del jumper en BTS

Shorter jumper

Longer jumper

For internal use


49
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Kits de tierra

Detail

Note:The photo shows the


Ground system at outdoor
site in Singapore.

For internal use


50
Nokia Siemens Networks

Presentation / Author / Date

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

ANTENNA LINE
Kits de tierra

EMP
EMP para cada
linea es opcional
Si se usa MHA ,
solo se usaran
kits de tierra
Si el tramo vertical es mayor a
40m , se necesita un kit de
tierra en la parte central
Kit de tierra

Barra de tierra
For internal use
51
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Kits de tierra

El kit de tierra siempre se deb ubicar en el tramo recto del cable, nunca en una curva.

Instalacin
Aceptable

For internal use


52
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Cableado de kits de tierra

EMP GROUNDING
BUSBAR

FEEDER ENTRY
GROUNDING
BUSBAR

For internal use


53
Nokia Siemens Networks

Presentation / Author / Date

Los EMP o kits de tierra deben ser


conectado a una barra de tierra
Los cables coaxiales deben tner un kit de
tierra antes del pasamuro.
Se deben usar las herramientas adecuadas
al instalar los kits de tierra
Los cables deben ser fijados correctamente

ANTENNA LINE
Cableado de kits de tierra

Los EMP o kits de tierra deben ser


conectado a una barra de tierra
Los cables coaxiales deben tner un kit de
tierra antes del pasamuro.
Se deben usar las herramientas adecuadas
al instalar los kits de tierra
Los cables deben ser fijados correctamente

FEEDER
GROUNDING
BUSBAR

For internal use


54
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Cableado de kits de tierra

Los EMP o kits de tierra deben ser


conectado a una barra de tierra
Los cables coaxiales deben tner un kit de
tierra antes del pasamuro.
Se deben usar las herramientas adecuadas
al instalar los kits de tierra
Los cables deben ser fijados correctamente

FEEDER
GROUNDING
BUSBAR

For internal use


55
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin a tierra de los EMP

Barra de tierra aislada

A antena

Jumper a BTS

EMP

Cable de tierra de EMP

Hacia la tierra principal

For internal use


56
Nokia Siemens Networks

Presentation / Author / Date

aislador

ANTENNA LINE
Conexin a tierra de los kits de tierra

A antena

Barra de tierra aislada


A BTS

Cable de tierra del kit de


tierra

A tierra principal

For internal use


57
Nokia Siemens Networks

Presentation / Author / Date

aislador

ANTENNA LINE
Posicin de los conectores

El conector no debe tocar


la escalerilla.
De no ser posible , aislar
la escalerilla con cinta
aislante.

For internal use


58
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Weather Proofing

Todas las conexiones de los cables coaxiales que esten a la


intemperie, deben ser vulcanizados y encintados.
Conexiones a encintar:
Coaxial con jumper
Coaxial con antena y MHA
Coaxial con EMP y combinador (en el caso que este a la
intemperie)
Los kits de tierra de ber ser sellados de acuerdo a las
especificaciones.
Los pasamuros deben estar correctamente sellados.
Asegurar que los torques en las conexiones sean las correctas antes
de encintar!

encintados

For internal use


59
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin Feeder con jumper

1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA.


2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA
3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
20

50

50

20

1. UNA CAPA DE CINTA AISLANTE

2. DOS CAPAS DE CINTA VULACANIZNATE

For internal use


60
Nokia Siemens Networks

Presentation / Author / Date

3. TRES CAPAS DE CINTA AISLANTE

ANTENNA LINE
Feeder to Antenna, Combiner or MHA connection

1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA.


2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA
3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
TIE WRAP
50

20

1. UNA CAPA DE CINTA


AISLANTE
2. DOS CAPAS DE CINTA VULACANIZNATE
1. TRES CAPAS DE CINTA
AISLANTE
For internal use
61
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Feeder to EMP connection

1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA.


2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA
3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
20

TIE WRAP

50

50

20

1. UNA CAPA DE CINTA


AISLANTE
2. DOS CAPAS DE CINTA VULACANIZNATE

For internal use


62
Nokia Siemens Networks

Presentation / Author / Date

1. TRES CAPAS DE CINTA


AISLANTE

ANTENNA LINE
Feeder to Grounding kit connection

2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA


3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
* Usar este metodo si los kits de tierra no vienen con cintas o sin instrucciones
20

50

100

20

2. DOS CAPAS DE CINTA VULACANIZNATE

1. TRES CAPAS DE CINTA


AISLANTE

For internal use


63
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Pasamuros

Usar sellos apropiados.


Sellar la entrada de cables apropiadamente.

NOK

For internal use


64
Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Comisionamiento

Seguir las intrucciones dadas para las mediciones.


Colocar las mediciones en el Site Folder.
Imprimir las graficas en papel A4 y adjuntar al Site Folder.
Tres graficas por pagina
Adjuntar los archivos en formato electronico
ANTENNA LINE

RETURN LOSS

RETURN LOSS

RETURN LOSS

For internal use


65
Nokia Siemens Networks