COMMUNICATION CABLE

Product Diagram

Specification
Pair
Conductor

Structure
Diameter
Insulation
Thickness(mm)
Diameter
Material
Light Armoured
Core wrapping Tape
Material
Thickness(mm)
Taping
Jacket Color
Cable Diameter
Outer Sheath
Packing
Length Difference
Installation Temperature
StorageTemperature
Net Weight(KG/1000M)

20
Solid
0.400.01mm
0.250.005
0.720.01
HDPE
Aluminium
Foil
0.050.01
PET+Tieyarn
Black
10.00.5mm
PE
1000m
0.5%
0C~+50C
-20C~+60C
117kg

Electrical Characteristics
Resistance(ohms/km)
Insulation Resistance(Gohms/km )
Dielectric Strength
Conductor to
Conductor
Mutual Capacitance(nF/Km)
Capacitance
Pair to pair
Unbalance(pF/Km)
Pair to ground
Propagation Delay
Working Capacitance
NVP

1/3

58
10
2.4kv (3 sec)
524
275
1500
466ns/100m
5.1nF/100m
0.21%
http://www.shipgroup.net/

COMMUNICATION CABLE
-40 to 60

Operating Temperature()

Performance Characteristic
Frequency(MHz)
1
4
10
16
20
31.25
62.5
100

Attenuation(dB)
2.1
3.9
6.2
7.9
8.9
11.17
16.22
20.96

NEXT(dB)
60
54.8
48.5
45.2
43.7
40.5
35.7
32.3

PS-NEXT(dB)
57
51.8
45.5
42.2
40.7
37.5
32.7
29.3

ACRF (dB)
62.3
53.3
47.3
44.2
42.8
39.9
35.4
32.3

PS-ACRF (dB)
61
49
41
36.9
35
31.1
25.1
21

Return Loss(dB)
19
19
19
19
19
17.1
14.1
12

Mechanical Characteristics
Elongation Of The Conductor (Average)
Insulation Tensile Strength (Median)
Insulation Elongation At Break (Median)
Sheath Tensile Strength (Median)
Sheath Elongation At Break (Median)
Insulated Cores Disconnected And Mixed Line

15%
15MPa
605%
10MPa
300%
No disconnected and mixed line

Ordering Information and Compliance


Part No.

Description

HYA26020-2

Communication Backbone Cable, 20Pair PE Black

2/3

Compliance
ANSI/ICEA S-90-661
TIA/EIA-568-C.2