You are on page 1of 2

insert_job: ABBV_PBLAE0202_CMD_SCM_LOAD_GRAPH

job_type: cmd
description: Start SCM_LOAD Job
machine: UA00575P
owner: ailae
group: Lavastorm
application: SCM_LOAD
max_run_alarm: 0
alarm_if_fail: y
avg_runtime: 32
send_notification: n
std_out_file: >/opt/lavastorm/autosys/${AUTO_JOB_NAME}_${AUTORUN}.txt
std_err_file: >/opt/lavastorm/autosys/${AUTO_JOB_NAME}_${AUTORUN}.err
command: /opt/lavastorm/sched/scm_load/start_scm_load_production.sh
insert_job: ABBV_PBLAE0203_CMD_SCM_SUSPENSE_RECORDS
job_type: cmd
description: Transaction suspense after data mart builds
machine: UA00575P
condition: s(ABBV_PADWR0022_SCM_DATAMART,03.00) & s(AI_PADWL0072_SCM_DATAMART,03
.00)
owner: ailae
group: Lavastorm
application: SCM_LOAD
max_run_alarm: 0
alarm_if_fail: y
send_notification: n
std_out_file: >/opt/lavastorm/autosys/${AUTO_JOB_NAME}_${AUTORUN}.txt
std_err_file: >/opt/lavastorm/autosys/${AUTO_JOB_NAME}_${AUTORUN}.err
command: /opt/lavastorm/sched/scm_load/start_scm_load_2_production.sh

insert_job: ABBV_PADWR0021_SCM_TRANS_DATA job_type: cmd


description: ROW SCM Transactional Data Load
machine: WA01565P
owner: SVC-AI-AUTOSYS-STG@ABBVIENET
group: Lavastorm
application: SCM
max_run_alarm: 120
alarm_if_fail: y
term_run_time: 120
send_notification: n
std_out_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.txt"
std_err_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.err"
command: E:\Kalido\Scripts\DataLoads_OneView\ADWSCMLoad.bat
condition: s(ABBV_PBLAE0202_CMD_SCM_LOAD_GRAPH)
insert_job: ABBV_PADWR0022_SCM_DATAMART job_type: cmd
description: ROW SCM Datamart Build
machine: WA01565P
owner: SVC-AI-AUTOSYS-STG@ABBVIENET
group: Lavastorm
application: SCM
max_run_alarm: 120
alarm_if_fail: y
term_run_time: 120
send_notification: n
std_out_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.txt"
std_err_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.err"
command: E:\Kalido\Scripts\DataLoads_OneView\OneViewScript4-2SCMqdef.bat
condition: s(ABBV_PADWR0021_SCM_TRANS_DATA)

insert_job: AI_PADWL0071_SCM_TRANS_DATA job_type: cmd


description: WEC SCM Transactional Data Load
machine: WA01084P
owner: SVC-AI-AUTOSYS-STG@ABBVIENET
group: Lavastorm
application: SCM
max_run_alarm: 120
alarm_if_fail: y
term_run_time: 120
send_notification: n
std_out_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.txt"
std_err_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.err"
command: E:\Kalido\Scripts\DataLoads_OneView\ADWSCMLoad.bat
condition: s(ABBV_PBLAE0202_CMD_SCM_LOAD_GRAPH)
insert_job: AI_PADWL0072_SCM_DATAMART job_type: cmd
description: WEC SCM Datamart Build
machine: WA01084P
owner: SVC-AI-AUTOSYS-STG@ABBVIENET
group: Lavastorm
application: SCM
max_run_alarm: 120
alarm_if_fail: y
term_run_time: 120
send_notification: n
std_out_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.txt"
std_err_file: "E:\Kalido\Temp\%AUTO_JOB_NAME%_%AUTORUN%.err"
command: E:\Kalido\Scripts\DataLoads_OneView\OneViewScript4-2SCMqdef.bat
condition: s(AI_PADWL0071_SCM_TRANS_DATA)

You might also like